Key takeaway
Across 25 case-control studies of 2,932 people, those with type 2 diabetes (T2DM) had significantly lower 24-hour heart rate variability (HRV) than healthy controls, for example SDNN -0.65 (95% CI -0.83 to -0.47) and total power -1.52 (-2.13 to -0.91). Case-control data show association only, and the proposed glucose-damage explanation was not tested.
Study design
Evidence review
Reading basis
Published abstract
Reading focus
Design & applicability
The research question
Damage to the heart's autonomic nerves is common in type 2 diabetes and linked to high cardiovascular mortality, and HRV is used to measure it. The authors pooled published studies to estimate how T2DM affects HRV measures.
Who and how
Systematic review and meta-analysis. PubMed, Cochrane Library, Embase and Science Direct were searched on 1 October 2017. Included articles reported HRV in T2DM patients and healthy controls measured over 24 hours with Holter electrocardiogram, using Task Force measures: RR intervals, SDNN, pNN50, RMSSD, total power, low frequency (LF), high frequency (HF) and LF/HF ratio. Results are given as effect sizes with 95% CI.
What it found
The authors’ reported results. Read each estimate with its population and uncertainty.
- 1The meta-analysis included 25 case-control studies with 2,932 participants: 1,356 with T2DM and 1,576 healthy controls.
- 2T2DM patients had significantly lower HRV (P < 0.01): RR intervals -0.61 (95% CI -1.21 to -0.01), SDNN -0.65 (-0.83 to -0.47), RMSSD -0.92 (-1.37 to -0.47), pNN50 effect size -0.46 (95% CI -0.84 to -0.09), total power -1.52 (-2.13 to -0.91), LF -1.08 (-1.46 to -0.69) and HF -0.79 (-1.09 to -0.50).
- 3The LF/HF ratio did not differ between groups.
- 4Blood glucose, HbA1c and time since T2DM diagnosis were associated with several HRV parameters.
Limits & uncertainty
- 1Case-control comparisons cannot establish that diabetes lowered HRV, and differences in age, fitness or medication between the groups are not described in the abstract.
- 2The abstract gives no heterogeneity statistics, and the RR interval interval nearly reaches zero (-1.21 to -0.01), so that finding is borderline.
- 3Only studies with 24-hour Holter recordings were included, so the results do not directly apply to short or wearable-based measurements.
- 4The explanation that altered glucose metabolism damaged autonomic nerves is the authors' interpretation, and this reading is based on the abstract only.
What to take from it
On average, people with T2DM have lower HRV than healthy people, in line with reduced autonomic nerve function, and HRV measures relate to glucose control. This does not let anyone judge their own nerve health from one HRV number. Concerns about diabetes complications should be discussed with a clinician.
Reading your own data
Wearable HRV usually comes from short overnight or morning readings, not the 24-hour Holter recordings used here, so numbers are not directly comparable. If you have diabetes, tracking your own HRV trend alongside glucose or HbA1c with the same device and timing may be informative, but use it to see change, not to diagnose.
How to read this evidence
Check which designs were included, how searches and bias assessment were conducted, and the last search date. Publication date alone does not make the underlying evidence current.
Authors’ structured abstract English
The attributed English abstract is reproduced under the recorded open licence. It is source material, not a MoveVitals interpretation. The prepared analysis above separates the authors’ findings from our interpretation.
Background
Cardiac autonomic neuropathy in type 2 dibetes mellitus (T2DM) patients is frequent and associated with high cardiovascular mortality. Heart rate variability (HRV) is the gold standard to measure cardiac autonomic neuropathy. We aimed to conduct a systematic review and meta-analysis to evaluate the impact of T2DM on HRV parameters.
Methods
The PubMed, Cochrane Library, Embase and Science Direct databases were searched on 1st October 2017 using the keywords "diabetes" AND ("heart rate variability" OR "HRV"). Included articles had to report HRV parameters in T2DM patients and healthy controls measured during 24 hours with a Holter-electrocardiogram. Measurements of HRV retieved were: RR-intervals (or Normal to Normal intervals-NN), standard deviation of RR intervals (SDNN), percetange of adjacent NN intervals differing by more than 50 milliseconds (pNN50), square root of the mean squared difference of successive RR intervals (RMSSD), total power, Low Frequency (LF), High Frequency (HF) and LF/HF ratio, as per Task Force recommendations.
Results
We included twenty-five case-control studies with 2,932 patients: 1,356 with T2DM and 1,576 healthy controls. T2DM patients had significantly (P<0.01) lower RR-intervals (effect size = -0.61; 95%CI -1.21 to -0.01), lower SDNN (-0.65; -0.83 to -0.47), lower RMSSD (-0.92; -1.37 to -0.47), lower pNN50 (-0.46; -0.84 to -0.09), lower total power (-1.52; -2.13 to -0.91), lower LF (-1.08; -1.46 to -0.69]), and lower HF (-0.79; -1.09 to -0.50). LF/HF did not differ between groups. Levels of blood glucose and HbA1c were associated with several HRV parameters, as well as Time from diagnosis of T2DM.
Conclusions
T2DM was associated with an overall decrease in the HRV of T2DM patients. Both sympathetic and parasympathetic activity were decreased, which can be explained by the deleterious effects of altered glucose metabolism on HRV, leading to cardiac autonomic neuropathy.
Sources & attribution
Heart rate variability in type 2 diabetes mellitus: A systematic review and meta-analysis.
Benichou T, Pereira B, Mermillod M, Tauveron I, Pfabigan D, Maqdasy S, Dutheil F.
PloS one · 2018-04-02
DOI: 10.1371/journal.pone.0195166 ↗PubMed · 29608603 ↗Europe PMC · Recorded licence: cc by ↗Abstract © the original authors, reproduced under the recorded open licence. Translations support reading; use the English record to check terminology and numerical results. Our methodological interpretation is separate from the authors’ conclusions.
MoveVitals editorial interpretation · educational content · no individual clinical review recorded
Sources checked 2026-11-01
Practical guides
Read in context
Short-term HRV was higher during slow breathing in 962 military men, injured or not
In 962 military men (median age 37.6 years), every short-term heart rate variability (HRV) measure was higher during slow breathing at six breaths a minute than during spontaneous breathing, injured or not; in fast resting breathers RMSSD rose from 15.57 to 21.89 ms. It was one session in a fixed order, so it shows an immediate effect, not lasting benefit.
European Journal of Applied Physiology
Cold-water immersion: no strength gain, briefly weaker jumps, soreness relief uncertain
Across 22 randomised trials (375 participants, mostly men), one cold-water immersion after exercise did not change maximal isometric strength (g 0.08, 95% CI −0.11 to 0.26) and was followed by weaker jumping straight afterwards (g −0.68), gone by 24–48 hours. Lower soreness and creatine kinase looked favourable but weakened in sensitivity checks, and certainty was low to very low.
PeerJ
Cold-water immersion after hard exercise: less soreness, better power, no strength gain
In a meta-analysis of 52 randomised trials, cold-water immersion after high-intensity exercise was followed 24 hours later by lower soreness (SMD −0.89), higher perceived recovery (0.66) and better muscular power (0.22), with no effect on strength. Participants could not be blinded, most were men, and many pooled results rest on few studies with high heterogeneity.
Sports Medicine
Acute:chronic workload ratio: no evidence it can reduce injury risk, authors argue
The authors argue there is no evidence for using the acute:chronic workload ratio (ACWR) in training-load management or to reduce injury risk: no study has properly estimated a causal effect, and the ratio is statistically inaccurate and ambiguous. This is a methodological critique, not a new data analysis, so it does not show that training load is unrelated to injury.
International Journal of Sports Physiology and Performance