Key takeaway
In 47 people followed for 4 weeks, several smartwatch-derived heart rate variability (HRV) measures, including RMSSD and SDNN, were significantly associated with depression scores, and SDNN, SDSD and LF with anxiety scores, with all HRV metrics correlating negatively with symptoms. Few correlations reached significance, and the sample was small and not made up of clinically diagnosed patients.
Study design
Cohort study
Reading basis
Published abstract
Reading focus
Association & confounding
The research question
If a smartwatch could pick up signs of depression or anxiety, mental health monitoring would be far easier to access. The authors checked whether HRV calculated from the watch's optical pulse signal tracks self-reported depression and anxiety symptoms over time.
Who and how
Four-week longitudinal study of 47 participants. Time-domain and frequency-domain HRV metrics were derived from photoplethysmography (PPG) signals recorded by smartwatches. Depression and anxiety symptoms were assessed with the Patient Health Questionnaire-9 (PHQ-9) and Generalized Anxiety Disorder-7 (GAD-7) at baseline, week 2 and week 4. The abstract does not report the participants' ages, devices, or the correlation sizes.
What it found
The authors’ reported results. Read each estimate with its population and uncertainty.
- 1Five HRV measures (RMSSD, SDNN, SDSD, LF, and the LF/HF ratio) were significantly associated with PHQ-9 depression scores, although the number of significant correlations was relatively small.
- 2Only SDNN, SDSD and LF showed significant correlations with GAD-7 anxiety scores.
- 3All HRV metrics correlated negatively with self-reported symptoms, meaning lower HRV went with higher symptom scores.
- 4HRV metrics reflecting parasympathetic (rest-and-digest) activity showed weaker correlations with depression and anxiety scores.
Limits & uncertainty
- 1With 47 participants and many HRV measures tested against two questionnaires, a few significant correlations could arise by chance, and the abstract gives no effect sizes.
- 2Symptoms were self-reported on questionnaires, and the authors say the findings still need validation in clinically diagnosed patients.
- 3HRV came from a wrist PPG signal, which is less precise than chest-strap or electrocardiogram recordings, especially during movement.
- 4This reading is based on the abstract only.
What to take from it
Lower smartwatch HRV tended to go along with higher depression and anxiety scores, but the links were modest and sparse, so HRV cannot tell you whether you are depressed or anxious. If you are worried about your mood, a conversation with a clinician is a much better route than reading HRV numbers.
Reading your own data
Many watches report HRV from PPG, so this paper is directly relevant to the data you may already have. Compare readings from the same device, taken at the same time such as overnight, and look at multi-week trends rather than a single day, since HRV swings with sleep, stress, alcohol and illness.
How to read this evidence
Exposure precedes follow-up outcomes, but confounding and reverse causation can remain. A hazard ratio is not an individual absolute risk or a demonstrated intervention effect.
Authors’ structured abstract English
The attributed English abstract is reproduced under the recorded open licence. It is source material, not a MoveVitals interpretation. The prepared analysis above separates the authors’ findings from our interpretation.
Background
Elucidating the association between heart rate variability (HRV) metrics obtained through non-invasive methods and mental health symptoms could provide an accessible approach to mental health monitoring. This study explores the correlation between HRV, estimated using photoplethysmography (PPG) signals, and self-reported symptoms of depression and anxiety.
Methods
A 4-week longitudinal study was conducted among 47 participants. Time-domain and frequency-domain HRV metrics were derived from PPG signals collected via smartwatches. Mental health symptoms were evaluated using the Patient Health Questionnaire-9 (PHQ-9) and Generalized Anxiety Disorder-7 (GAD-7) at baseline, week 2, and week 4.
Results
Among the investigated HRV metrics, RMSSD, SDNN, SDSD, LF, and the LF/HF ratio were significantly associated with the PHQ-9 score, although the number of significant correlations was relatively small. Furthermore, only SDNN, SDSD and LF showed significant correlations with the GAD-7 score. All HRV metrics showed negative correlations with self-reported clinical symptoms.
Conclusions
Our findings indicate the potential of PPG-derived HRV metrics in monitoring mental health, thereby providing a foundation for further research. Notably, parasympathetically biased HRV metrics showed weaker correlations with depression and anxiety scores. Future studies should validate these findings in clinically diagnosed patients.
Sources & attribution
Association between heart rate variability metrics from a smartwatch and self-reported depression and anxiety symptoms: a four-week longitudinal study.
Jo YT, Lee SW, Park S, Lee J.
Frontiers in psychiatry · 2024-05-31
DOI: 10.3389/fpsyt.2024.1371946 ↗PubMed · 38881544 ↗Europe PMC · Recorded licence: cc by ↗Abstract © the original authors, reproduced under the recorded open licence. Translations support reading; use the English record to check terminology and numerical results. Our methodological interpretation is separate from the authors’ conclusions.
MoveVitals editorial interpretation · educational content · no individual clinical review recorded
Sources checked 2026-11-01
Practical guides
Read in context
Short-term HRV was higher during slow breathing in 962 military men, injured or not
In 962 military men (median age 37.6 years), every short-term heart rate variability (HRV) measure was higher during slow breathing at six breaths a minute than during spontaneous breathing, injured or not; in fast resting breathers RMSSD rose from 15.57 to 21.89 ms. It was one session in a fixed order, so it shows an immediate effect, not lasting benefit.
European Journal of Applied Physiology
Cold-water immersion: no strength gain, briefly weaker jumps, soreness relief uncertain
Across 22 randomised trials (375 participants, mostly men), one cold-water immersion after exercise did not change maximal isometric strength (g 0.08, 95% CI −0.11 to 0.26) and was followed by weaker jumping straight afterwards (g −0.68), gone by 24–48 hours. Lower soreness and creatine kinase looked favourable but weakened in sensitivity checks, and certainty was low to very low.
PeerJ
Cold-water immersion after hard exercise: less soreness, better power, no strength gain
In a meta-analysis of 52 randomised trials, cold-water immersion after high-intensity exercise was followed 24 hours later by lower soreness (SMD −0.89), higher perceived recovery (0.66) and better muscular power (0.22), with no effect on strength. Participants could not be blinded, most were men, and many pooled results rest on few studies with high heterogeneity.
Sports Medicine
Acute:chronic workload ratio: no evidence it can reduce injury risk, authors argue
The authors argue there is no evidence for using the acute:chronic workload ratio (ACWR) in training-load management or to reduce injury risk: no study has properly estimated a causal effect, and the ratio is statistically inaccurate and ambiguous. This is a methodological critique, not a new data analysis, so it does not show that training load is unrelated to injury.