Skip to content
Wearables & measurementEvidence review3 min read

Wearable motion sensors measure average gait timing well, but not gait variability

MoveVitals Editorial Collective · Study published · Reading updated

Original paper:Validity and reliability of wearable inertial sensors in healthy adult walking: a systematic review and meta-analysis. · Journal of neuroengineering and rehabilitation · 2020 · Original paper ↗

Key takeaway

Across 82 articles in healthy adults, inertial sensors measured step and stride times with excellent validity and reliability, while variability and symmetry measures were poor to moderate. The evidence is thin: the median study had only 12 participants.

Study design

Evidence review

Reading basis

Published abstract

Reading focus

Design & applicability

The research question

Inertial measurement units (IMUs), the motion sensors in many wearables, can capture how a person walks, but no one had pooled the large body of validity and reliability studies. The authors asked how accurate and repeatable IMUs are for gait measures during level walking in healthy adults.

Who and how

Systematic review and meta-analysis. Five electronic databases were searched, two reviewers screened studies and two rated methodological quality. When enough data existed, Pearson correlation coefficients (r) were pooled for concurrent validity and intraclass correlation coefficients (ICC) for test-retest reliability. Outcomes that could not be pooled were summarised qualitatively. A total of 82 articles covering over 100 outcomes were included.

What it found

The authors’ reported results. Read each estimate with its population and uncertainty.

  1. 1
    17 biomechanical outcomes, mostly spatiotemporal parameters such as step timing, were meta-analyzed.
  2. 2
    Validity and reliability of step and stride times were excellent. Step and stride length, swing time and stance time were good to excellent.
  3. 3
    Variability and symmetry of spatiotemporal parameters had poor to moderate validity and reliability. Local dynamic stability showed moderate reliability.
  4. 4
    The authors tentatively support IMUs for joint angles, stability, regularity and segmental accelerations, but call for strict protocols when using variability and symmetry metrics.

Limits & uncertainty

  1. 1
    Many included studies were small and underpowered or did not justify their sample size: the median was 12 participants (range 2-95), which the authors call the main limitation.
  2. 2
    There were few high-quality studies for each outcome, so recommendations for the less common measures are weak.
  3. 3
    Only healthy adults walking on level ground were studied, so the findings may not hold for older or injured people, or on stairs and uneven ground.
  4. 4
    This reading is based on the abstract only, which does not give the pooled r or ICC values.

What to take from it

If a sensor reports average step time or stride length from normal walking, the research suggests you can trust it fairly well. Reports of gait symmetry or step-to-step variability deserve more caution unless the test is carefully standardised. Concerns about how you walk are a question for a clinician or physiotherapist.

Reading your own data

Foot-worn and waist-worn sensors, and some watches and phones, estimate cadence, stride length and sometimes symmetry. Compare these only against yourself, with the same device, placement and walking surface, and treat symmetry or variability scores as rough.

How to read this evidence

Check which designs were included, how searches and bias assessment were conducted, and the last search date. Publication date alone does not make the underlying evidence current.

Authors’ structured abstract English

The attributed English abstract is reproduced under the recorded open licence. It is source material, not a MoveVitals interpretation. The prepared analysis above separates the authors’ findings from our interpretation.

Background

Inertial measurement units (IMUs) offer the ability to measure walking gait through a variety of biomechanical outcomes (e.g., spatiotemporal, kinematics, other). Although many studies have assessed their validity and reliability, there remains no quantitive summary of this vast body of literature. Therefore, we aimed to conduct a systematic review and meta-analysis to determine the i) concurrent validity and ii) test-retest reliability of IMUs for measuring biomechanical gait outcomes during level walking in healthy adults.

Methods

Five electronic databases were searched for journal articles assessing the validity or reliability of IMUs during healthy adult walking. Two reviewers screened titles, abstracts, and full texts for studies to be included, before two reviewers examined the methodological quality of all included studies. When sufficient data were present for a given biomechanical outcome, data were meta-analyzed on Pearson correlation coefficients (r) or intraclass correlation coefficients (ICC) for validity and reliability, respectively. Alternatively, qualitative summaries of outcomes were conducted on those that could not be meta-analyzed.

Results

A total of 82 articles, assessing the validity or reliability of over 100 outcomes, were included in this review. Seventeen biomechanical outcomes, primarily spatiotemporal parameters, were meta-analyzed. The validity and reliability of step and stride times were found to be excellent. Similarly, the validity and reliability of step and stride length, as well as swing and stance time, were found to be good to excellent. Alternatively, spatiotemporal parameter variability and symmetry displayed poor to moderate validity and reliability. IMUs were also found to display moderate reliability for the assessment of local dynamic stability during walking. The remaining biomechanical outcomes were qualitatively summarized to provide a variety of recommendations for future IMU research.

Conclusions

The findings of this review demonstrate the excellent validity and reliability of IMUs for mean spatiotemporal parameters during walking, but caution the use of spatiotemporal variability and symmetry metrics without strict protocol. Further, this work tentatively supports the use of IMUs for joint angle measurement and other biomechanical outcomes such as stability, regularity, and segmental accelerations. Unfortunately, the strength of these recommendations are limited based on the lack of high-quality studies for each outcome, with underpowered and/or unjustified sample sizes (sample size median 12; range: 2-95) being the primary limitation.

Sources & attribution

Validity and reliability of wearable inertial sensors in healthy adult walking: a systematic review and meta-analysis.

Kobsar D, Charlton JM, Tse CTF, Esculier JF, Graffos A, Krowchuk NM, Thatcher D, Hunt MA.

Journal of neuroengineering and rehabilitation · 2020-05-11

DOI: 10.1186/s12984-020-00685-3 ↗PubMed · 32393301 ↗Europe PMC · Recorded licence: cc by ↗

Abstract © the original authors, reproduced under the recorded open licence. Translations support reading; use the English record to check terminology and numerical results. Our methodological interpretation is separate from the authors’ conclusions.

MoveVitals editorial interpretation · educational content · no individual clinical review recorded

Sources checked 2026-11-01

Practical guides

Read in context

·Cohort study

Activity–stroke and heart attack curves differ by accelerometer processing method

Among 90,237 UK Biobank adults free of cardiovascular disease at baseline, followed until December 2022 for 1,298 strokes and 2,031 myocardial infarctions, the shape of the link between moderate-vigorous physical activity (MVPA) and each outcome depended on how the accelerometer data were processed. For stroke, hazard fell in a straight line only with the machine-learning metric; for myocardial infarction, two metrics gave a curved decline and activity counts a straight one. The abstract gives no hazard ratios, so it shows that methods disagree, not which one is right, and the findings are observational associations.

Preventive Medicine

In-depth explainersRead study →
·Validation study/review

Smartwatch data as forensic evidence: heart rate is best validated, the rest uneven

A systematic review and meta-analysis of studies on smartwatches from four major brands, framed around digital forensics, found that heart rate was both the most studied and the most accurate measure. Step count, distance, energy expenditure, activity classification and sleep were less consistently validated, and results varied by brand, protocol and reporting. The abstract gives no pooled numbers, and most studies were run in healthy people in laboratories, so it cannot say how a particular watch performs for a particular person in daily life.

Forensic Science International

In-depth explainersRead study →
·Overview of reviews

Activity trackers: about 1,800 more steps a day, but small effects on other outcomes

An umbrella review of 39 systematic reviews and meta-analyses, covering 163,992 participants, found that activity trackers were associated with more physical activity (SMD 0.3–0.6), equating to about 1,800 extra steps and 40 minutes more walking per day, and with a bodyweight reduction of about 1 kg. Effects on blood pressure, cholesterol, glycosylated haemoglobin, quality of life and pain were typically small and often non-significant. The abstract does not say what else came with the trackers in these programs or how much the reviews overlap, so the gains cannot be credited to the device alone.

The Lancet Digital Health

In-depth explainersRead study →
·Validation study/review

Seven sleep trackers: good at spotting sleep, weak on wake and sleep stages

In a sleep laboratory, 34 healthy young adults wore a subset of seven consumer sleep trackers for three nights. Against polysomnography every device detected sleep very well (sensitivity 0.93 or higher) but caught wake poorly (specificity 0.18–0.54), and five of the seven matched or beat research actigraphy (specificity 0.39). Sleep-stage estimates were inconsistent, and the participants were healthy adults aged 18 to 35 in a fixed 8-hour bed window, with each device tested in only 11 to 20 of them, so the results say little about people with sleep problems.

Sleep

In-depth explainersRead study →
Wearables & measurement →