Skip to content
Recovery & autonomic healthEvidence review3 min read

After tilting, people with POTS had higher heart rate and lower short-term HRV than healthy people

MoveVitals Editorial Collective · Study published · Reading updated

Original paper:Heart rate and heart rate variability comparison between postural orthostatic tachycardia syndrome versus healthy participants; a systematic review and meta-analysis. · BMC cardiovascular disorders · 2019 · Original paper ↗

Key takeaway

Pooling 20 studies of 717 people with postural orthostatic tachycardia syndrome (POTS) and 641 healthy people, the POTS group had a higher heart rate and lower rMSSD (a time-domain HRV measure) after a head-up tilt test (both p < 0.05). Frequency-domain HRV measures did not differ significantly (all p > 0.05), and the abstract gives no effect sizes.

Study design

Evidence review

Reading basis

Published abstract

Reading focus

Design & applicability

The research question

Heart rate variability (HRV) is often used to assess how the autonomic nervous system is working, but in POTS it is heavily affected by age, sex, race, fitness and time of day. The authors pooled published studies to compare heart rate and HRV in people with POTS against healthy participants after a head-up tilt test.

Who and how

Systematic review and meta-analysis of observational studies, searching MEDLINE (via PubMed), EMBASE and SCOPUS for studies comparing POTS patients with healthy participants on heart rate (HR) and HRV. Time-domain HRV was the mean RR interval and rMSSD (the root mean square of successive R-R differences) in milliseconds; frequency-domain HRV was low frequency (LF) and high frequency (HF) power, the LF/HF ratio, and LF and HF in normalised units. Group means were compared as mean differences using RevMan 5.3 at a 95% significance level.

What it found

The authors’ reported results. Read each estimate with its population and uncertainty.

  1. 1
    20 studies were eligible, reporting 717 people with POTS and 641 healthy participants.
  2. 2
    The POTS group had a higher mean heart rate, a lower mean RR interval and a lower rMSSD than healthy participants, each with p < 0.05.
  3. 3
    Frequency-domain measures pointed in the direction of lower HF, lower LF, lower normalised HF, a higher LF/HF ratio and a higher normalised LF in POTS, but none of these differences was statistically significant (all p > 0.05).
  4. 4
    The authors conclude that heart rate and time-domain HRV separate POTS patients from healthy people more reliably than frequency-domain HRV, and they call for sensitivity and specificity studies.

Limits & uncertainty

  1. 1
    The included studies were observational, and the abstract itself notes that HRV in POTS is confounded by age, sex, race, fitness and circadian rhythm.
  2. 2
    The abstract gives no mean differences or confidence intervals, so the size of the gaps is unknown.
  3. 3
    Differences were measured after a head-up tilt test in a lab, so they say little about HRV during everyday life or sleep.
  4. 4
    No sensitivity or specificity was tested, so the claim that these measures are 'more reliable' for telling POTS from healthy has not been evaluated as a diagnostic test. This reading is based on the abstract only.

What to take from it

The findings fit what people with POTS often see: a faster heart rate and a more subdued short-term variability in the tilt test. HRV is not a diagnostic test for POTS, and this review does not show it can pick out one person with the condition. Anyone with symptoms such as racing heart on standing should see a clinician for proper testing.

Reading your own data

Resting heart rate and RMSSD-style HRV are commonly reported by chest straps and some wearables, but your readings will depend on posture, time of day and the device. Use the same device and conditions, and compare your own trend over weeks, not one reading; a single number cannot indicate POTS.

How to read this evidence

Check which designs were included, how searches and bias assessment were conducted, and the last search date. Publication date alone does not make the underlying evidence current.

Authors’ structured abstract English

The attributed English abstract is reproduced under the recorded open licence. It is source material, not a MoveVitals interpretation. The prepared analysis above separates the authors’ findings from our interpretation.

Background

A number of published literature has reported that, physiologically, heart rate variability (HRV) in patients with postural orthostatic tachycardia syndrome (POTS) to be greatly confounded by age, sex, race, physical fitness, and circadian rhythm. The purpose of this study was to compare between POTS patients versus healthy participants, in terms of heart rate (HR) and HRV after Head-Up tilt test (HUTT), by systematic review and meta-analysis of available published literature.

Methods

MEDLINE (using PubMed interphase), EMBASE and SCOPUS were systematically searched for observational studies comparing POTS patients versus healthy patients, in terms of HR and HRV. HRV was grouped into Time and frequency domain outcome measurements. The time domain was measured as mean RR- interval and mean the square root of the mean of squares of successive R-R waves (rMSSD) in milliseconds. The frequency domain was measured as mean values of Low frequency power (LF), High frequency power (HF), LF/HF-ratio, LF-normalized units (LF(n.u)) and HF-normalized units (HF(n.u)). Demographic data, comorbidities, and mean values of HR, RR- interval, rMSSD, LF, HF, LF/HF-ratio, LF-(n.u) and H.F-n.u were extracted from each group and compared, by their mean differences as an overall outcome measure. Computer software, RevMan 5.3 was utilized, at a 95% significance level.

Results

Twenty (20) eligible studies were found to report 717 POTS and 641 healthy participants. POTS group had a higher mean HR (p < 0.05), lower mean RR-Interval (p < 0.05), lower rMSSD (p < 0.05) than healthy participants. Furthermore, POTS group had lower mean HF(p > 0.05), lower mean LF(p > 0.05), and lower mean HF(n.u) (p > 0.05), higher LF/HF-Ratio (p > 0.05) and higher LF(n.u) (p > 0.05) as compared to healthy participants.

Conclusion

POTS patients have a higher HR than healthy patients after HUTT and lower HRV in terms of time domain measure but not in terms of frequency domain measure. HR and time domain analyses of HRV are more reliable than frequency domain analysis in differentiating POTS patients from the healthy participants. We call upon sensitivity and specificity studies.

Sources & attribution

Heart rate and heart rate variability comparison between postural orthostatic tachycardia syndrome versus healthy participants; a systematic review and meta-analysis.

Swai J, Hu Z, Zhao X, Rugambwa T, Ming G.

BMC cardiovascular disorders · 2019-12-30

DOI: 10.1186/s12872-019-01298-y ↗PubMed · 31888497 ↗Europe PMC · Recorded licence: cc by ↗

Abstract © the original authors, reproduced under the recorded open licence. Translations support reading; use the English record to check terminology and numerical results. Our methodological interpretation is separate from the authors’ conclusions.

MoveVitals editorial interpretation · educational content · no individual clinical review recorded

Sources checked 2026-11-01

Practical guides

Read in context

·Research article

Short-term HRV was higher during slow breathing in 962 military men, injured or not

In 962 military men (median age 37.6 years), every short-term heart rate variability (HRV) measure was higher during slow breathing at six breaths a minute than during spontaneous breathing, injured or not; in fast resting breathers RMSSD rose from 15.57 to 21.89 ms. It was one session in a fixed order, so it shows an immediate effect, not lasting benefit.

European Journal of Applied Physiology

In-depth explainersRead study →
·Trial meta-analysis

Cold-water immersion: no strength gain, briefly weaker jumps, soreness relief uncertain

Across 22 randomised trials (375 participants, mostly men), one cold-water immersion after exercise did not change maximal isometric strength (g 0.08, 95% CI −0.11 to 0.26) and was followed by weaker jumping straight afterwards (g −0.68), gone by 24–48 hours. Lower soreness and creatine kinase looked favourable but weakened in sensitivity checks, and certainty was low to very low.

PeerJ

In-depth explainersRead study →
·Evidence review

Cold-water immersion after hard exercise: less soreness, better power, no strength gain

In a meta-analysis of 52 randomised trials, cold-water immersion after high-intensity exercise was followed 24 hours later by lower soreness (SMD −0.89), higher perceived recovery (0.66) and better muscular power (0.22), with no effect on strength. Participants could not be blinded, most were men, and many pooled results rest on few studies with high heterogeneity.

Sports Medicine

In-depth explainersRead study →
·Methods & interpretation

Acute:chronic workload ratio: no evidence it can reduce injury risk, authors argue

The authors argue there is no evidence for using the acute:chronic workload ratio (ACWR) in training-load management or to reduce injury risk: no study has properly estimated a causal effect, and the ratio is statistically inaccurate and ambiguous. This is a methodological critique, not a new data analysis, so it does not show that training load is unrelated to injury.

International Journal of Sports Physiology and Performance

In-depth explainersRead study →
Recovery & autonomic health →