Key takeaway
An expert overview of heart rate variability (HRV) concludes that 24-hour, 5-minute and ultra-short readings measure different things, so norms for one cannot be applied to another; pooled 5-minute norms from 21,438 healthy adults averaged 50 ms for SDNN and 42 ms for RMSSD. It is a narrative review, not a trial, and it tests no consumer wearable.
Study design
Methods & interpretation
Reading basis
Full text
Reading focus
Design & applicability
The research question
Heart rate variability is the beat-to-beat change in the time between heartbeats, and it is widely read as a window on how flexibly the nervous system steers the heart. Numbers such as SDNN or RMSSD are quoted from recordings of very different lengths, breathing conditions and populations, and the paper argues they are often compared as if they were the same thing. The authors set out to explain what each common time-domain, frequency-domain and non-linear metric reflects, how 24-hour, short-term (about 5 minutes) and ultra-short-term (under 5 minutes) recordings differ, and which published normal values exist for clinical, healthy and performance groups. They also aim to show how context such as recording length, age, sex and breathing changes baseline values, and how HRV can be used to assess clinical and performance interventions.
Who and how
This is a narrative overview, not a systematic review or a trial. The authors first explain the physiology behind HRV, meaning the changes in the interval between consecutive heartbeats (interbeat intervals), and then walk through the common metrics in three families: time-domain (how much variability there is, such as SDNN, RMSSD and pNN50), frequency-domain (how much signal energy sits in the ultra-low, very-low, low and high frequency bands defined by a 1996 task force) and non-linear (how unpredictable the interval series is, such as the Poincaré plot measures SD1 and SD2). For each metric they state the minimum recording length and what it is thought to reflect.
The second half surveys published normal values, tabulated by recording length. For ultra-short recordings under 5 minutes it covers five studies (from 24 to 3,387 participants, using ECG or photoplethysmography, a light-based pulse sensor). For short-term recordings of about 5 minutes it covers athletes, children and a review of 44 studies in 21,438 healthy adults. For 24-hour recordings it covers six studies of adults, with up to 2,079 participants. The text describes no formal search, study selection or quality rating. The authors note that most ultra-short-term studies relied on correlation and recommend the more rigorous Bland-Altman limits-of-agreement method, and they close with how norms can guide assessment before, during and after HRV biofeedback (paced-breathing training).
What it found
- 1Recording length changes what HRV means. A 24-hour recording is the clinical gold standard: SDNN below 50 ms was classed as unhealthy, 50–100 ms as compromised health and above 100 ms as healthy, and heart attack survivors with SDNN over 100 ms had a 5.3 times lower risk of mortality than those under 50 ms over a 31-month mean follow-up. In contrast, 5-minute SDNN does not predict future heart attack risk.
- 2RMSSD, the main time-domain marker of vagally mediated (rest-and-digest) change, holds up better in short recordings than SDNN. It is conventionally taken over 5 minutes, with 10, 30 and 60 seconds proposed. In 3,387 adults, 120-second RMSSD and SDNN agreed almost perfectly with 240–300-second values (r = 0.986 for RMSSD, 0.956 for SDNN), RMSSD agreed better at every length, and in 70 volunteers 10-second and 1-minute RMSSD tracked 5-minute RMSSD while SDNN did not. The authors judge that 1 minute may be enough for heart rate, SDNN and RMSSD in healthy people if artifacts are carefully removed.
- 3Frequency bands are easy to over-read. Changing breathing rate within 9–24 breaths/min changes high-frequency (HF) power without changing mean heart rate, so HF power and respiratory sinus arrhythmia reflect vagal modulation, not vagal tone, and breathing below 8.5 breaths/min pushes vagal oscillations into the low-frequency (LF) band. The LF/HF ratio is also a weak stand-in for sympathetic versus parasympathetic balance: half of the variability in the LF band comes from the parasympathetic system, and 24-hour and 5-minute LF/HF values correlate poorly.
- 4Typical resting values come with wide ranges, and they fall with age. In the review of 44 studies (21,438 healthy adults), 5-minute SDNN averaged 50 ms (SD 16, range 32–93) and RMSSD 42 ms (SD 15, range 19–75); paced breathing raised every index except LF power, and three large groups aged 40 or older may explain the comparatively low values. In 1,743 people aged 40–100, SDNN declined linearly while RMSSD and pNN50 fell from 40 to 60 and rose again after 70. In a meta-analysis of 296,247 healthy participants, women had a higher mean heart rate, lower SDNN and greater HF power than men.
- 5Measurement quality can matter as much as physiology. One study found ECG and PPG differed by less than 6% for most HRV measures but by 29.9% for pNN50; 500 Hz sampling may be needed when breathing-related variation is low, whereas 125 or 200 Hz may suffice when it is normal; and a single uncorrected artifact can outweigh the 0.5–1.0 Ln effect sizes typical of research. Higher is not always better: atrial fibrillation and other conduction abnormalities can raise HRV, and such elevated values are strongly linked to higher mortality risk, particularly in older people.
Limits & uncertainty
- 1The authors note that many of the ultra-short-term studies had serious methodological limitations: only one stated what correlation counted as acceptable agreement (for example r = 0.9), and correlation does not guarantee agreement, so how closely a 1-minute value tracks a 5-minute value is often unknown.
- 2The authors also note that norms are not interchangeable across ECG versus PPG, age, health status, breathing, body position, frequency-band cut-offs and spectral method, and that standardised ultra-short protocols and norms for healthy non-athletes, performance and clinical groups are still missing. They urge professionals to add values from their own populations.
- 3Our observation: the overview is narrative, with no systematic search or quality rating, and several cited norm samples are small or narrow, for example 24 healthy students, 38 undergraduates or 145 elite track-and-field athletes. The 24-hour SDNN bands are described for patients, and the mortality figure comes from heart attack survivors, not from healthy or athletic people.
- 4Our observation: the paper is from 2017 and draws on laboratory and clinical recordings. It does not test consumer wrist or ring devices, overnight HRV averages or the proprietary scores they report, and a few counts differ between the text and its tables, such as the size of the 24-hour Task Force reference sample.
What to take from it
For personal tracking, the safest use is your own baseline: measure HRV the same way every time (same device, time of day, posture, and either normal or paced breathing) and watch how your numbers move against your own typical range. Published averages such as an SDNN of 50 ms or an RMSSD of 42 ms describe groups measured in particular ways and are not targets or pass marks, and the 50 ms and 100 ms SDNN bands apply to 24-hour clinical recordings.
Do not conclude that a higher number is always better, that one low reading means disease, or that an LF/HF value tells you how stressed you are. Unusually high or erratic values can come from an irregular heart rhythm or a poor signal, and any heart or rhythm concern belongs with a clinician. This is an expert synthesis of published work rather than new data, so treat the norms as rough context.
Reading your own data
Pick one metric and one method, and log SDNN and RMSSD separately with their source and recording length, because the same name from a different recording length is a different number. Do not compare a 1-minute morning reading, a 5-minute reading and an overnight or 24-hour average with each other or with published norms. Pitfalls: a faster resting heart rate lowers HRV on its own, deep or paced breathing can raise RMSSD and HF without any change in vagal tone, and poor sensor contact or movement adds artifacts. Compare weeks, not single days.
How to read this evidence
A methods paper explains assumptions and interpretation; it does not by itself establish an intervention benefit or a personal clinical threshold.
Sources & attribution
An Overview of Heart Rate Variability Metrics and Norms
Frontiers in Public Health · 2017-09-28
DOI: 10.3389/fpubh.2017.00258 ↗PubMed · 29034226 ↗MoveVitals editorial interpretation · educational content · no individual clinical review recorded
Sources checked 2026-11-01
Practical guides
Read in context
Short-term HRV was higher during slow breathing in 962 military men, injured or not
In 962 military men (median age 37.6 years), every short-term heart rate variability (HRV) measure was higher during slow breathing at six breaths a minute than during spontaneous breathing, injured or not; in fast resting breathers RMSSD rose from 15.57 to 21.89 ms. It was one session in a fixed order, so it shows an immediate effect, not lasting benefit.
European Journal of Applied Physiology
Cold-water immersion: no strength gain, briefly weaker jumps, soreness relief uncertain
Across 22 randomised trials (375 participants, mostly men), one cold-water immersion after exercise did not change maximal isometric strength (g 0.08, 95% CI −0.11 to 0.26) and was followed by weaker jumping straight afterwards (g −0.68), gone by 24–48 hours. Lower soreness and creatine kinase looked favourable but weakened in sensitivity checks, and certainty was low to very low.
PeerJ
Cold-water immersion after hard exercise: less soreness, better power, no strength gain
In a meta-analysis of 52 randomised trials, cold-water immersion after high-intensity exercise was followed 24 hours later by lower soreness (SMD −0.89), higher perceived recovery (0.66) and better muscular power (0.22), with no effect on strength. Participants could not be blinded, most were men, and many pooled results rest on few studies with high heterogeneity.
Sports Medicine
Acute:chronic workload ratio: no evidence it can reduce injury risk, authors argue
The authors argue there is no evidence for using the acute:chronic workload ratio (ACWR) in training-load management or to reduce injury risk: no study has properly estimated a causal effect, and the ratio is statistically inaccurate and ambiguous. This is a methodological critique, not a new data analysis, so it does not show that training load is unrelated to injury.
International Journal of Sports Physiology and Performance

