Where a wrist or arm heart rate sensor sits changes its accuracy, especially in burpees

MoveVitals Editorial Collective · Study published · Reading updated

Original paper:Impact of Anatomical Placement on the Accuracy of Wearable Heart Rate Monitors During Rest and Various Exercise Intensities. · Sensors (Basel, Switzerland) · 2025 · Original paper ↗

Key takeaway

In 28 healthy young adults, optical heart rate monitors agreed closely with a chest strap at rest (CCC > 0.99), but agreement fell during burpees (CCC < 0.50), and three identical Whoop 4.0 units worn at different spots performed differently. The test used a small group of healthy people and a short exercise protocol, so it may not match everyday wear.

Study design

Validation study/review

Reading basis

Published abstract

Reading focus

Reference & error

The research question

Optical (photoplethysmography, PPG) heart rate sensors are sold for the wrist, forearm and upper arm, but it is unclear how much the body site matters once movement increases. The authors compared several arm-worn monitors with a chest strap across rest and different exercise intensities, and used three identical Whoop units to isolate the effect of placement alone.

Who and how

Validation study of 28 healthy adults (14 males, 14 females; aged 23.8 ± 1.1 years). Each wore six monitors: a Polar H10 chest strap (reference), a Polar Verity Sense on the forearm, a Garmin Forerunner on the wrist, and three identical Whoop 4.0 devices on the left wrist, forearm and upper arm. Participants did rest, warm-up, high-intensity burpees and graded treadmill exercise (Modified Bruce protocol). Agreement was assessed with mean absolute percentage error (MAPE), Bland-Altman analysis, concordance correlation coefficient (CCC) and Deming regression. The abstract does not report the actual error values.

What it found

The authors’ reported results. Read each estimate with its population and uncertainty.

  1. 1
    Accuracy was highest at rest and gradually declined as movement intensity rose. At rest every device showed minimal bias and high agreement with the chest strap (CCC > 0.99); the Verity Sense had the lowest MAPE.
  2. 2
    During warm-up, the upper-arm Whoop and the Verity Sense did better than the wrist-worn units and the Garmin, while the forearm Whoop showed proportional and systematic bias.
  3. 3
    Burpees gave the lowest accuracy for all devices (CCC < 0.50), although the upper-arm Whoop did better than the other placements.
  4. 4
    During the Modified Bruce treadmill protocol, the Verity Sense and the upper-arm Whoop agreed best with the chest strap. With identical Whoop hardware, the upper arm outperformed the forearm and wrist.

Limits & uncertainty

  1. 1
    Only 28 healthy adults with a mean age of 23.8 years took part, so results may not carry over to older people, people with heart conditions or different skin tones and wrist sizes.
  2. 2
    The exercise was short and lab-based (rest, warm-up, burpees, treadmill), not free-living training or sleep.
  3. 3
    Only three device brands/models were tested, and the abstract gives no numeric error values, so how large the placement difference is in beats per minute cannot be judged here.
  4. 4
    This reading is based on the abstract only.

What to take from it

If you want better optical heart rate during hard or jerky workouts, a snug position higher on the arm may help, but a chest strap remains the safer reference for interval or full-body sessions. Do not assume your own device matches these results; it was one small, young sample.

Reading your own data

Resting and steady-state heart rate from a wrist or arm sensor is generally reliable, so trends over days are meaningful. For burpee-style intervals, treat the reading as approximate and, if the number matters, compare the same device and placement against a chest strap on your own workouts.

How to read this evidence

Agreement is specific to the device, firmware, reference, population and setting. Correlation is not agreement, and validating a metric is not proof of diagnostic or treatment benefit.

Authors’ structured abstract English

The attributed English abstract is reproduced under the recorded open licence. It is source material, not a MoveVitals interpretation. The prepared analysis above separates the authors’ findings from our interpretation.

Purpose

This study evaluated the accuracy of arm-based photoplethysmography (PPG) wearable heart rate (HR) monitors in comparison to a validated chest strap reference across various activity levels.

Methods

Twenty-eight healthy adults (14 males, 14 females; aged 23.8 ± 1.1 years) wore six HR monitors: Polar H10 chest strap, Polar Verity Sense on the forearm, Garmin Forerunner on the wrist, and three identical Whoop 4.0 devices placed on the left wrist, forearm, and upper arm. Participants completed rest, warm-up, high-intensity burpees, and graded treadmill exercise. HR data were analyzed using mean absolute percentage error (MAPE), Bland-Altman analysis, concordance correlation coefficient (CCC), and Deming regression.

Results

Accuracy was highest at rest and gradually decreased as movement intensity increased. During rest, all devices showed minimal bias and high agreement (CCC > 0.99), with Verity Sense recording the lowest MAPE. In warm-up, Whoop-upper arm and Verity Sense outperformed wrist and Garmin positions, while the Whoop-forearm showed proportional and systematic bias. Burpees resulted in the lowest accuracy across devices (CCC < 0.50), but Whoop-upper arm performed better than other placements. During the Modified Bruce protocol, Verity Sense and Whoop-upper arm had the strongest agreement with the chest strap. Placement of identical Whoop units affected accuracy, with the upper arm outperforming forearm and wrist positions.

Conclusions

PPG wearables provided accurate HR monitoring at rest, during warm-up, and during steady-state graded exercise, particularly when positioned proximally (forearm or upper arm). Accuracy declined during short, high-intensity, full-body activities due to motion artifacts. Both the forearm-mounted Verity Sense and the upper-arm Whoop demonstrated the closest agreement with the chest-strap reference. The intra-device comparison of identical Whoop units confirmed that anatomical placement alone significantly affects accuracy.

Sources & attribution

Impact of Anatomical Placement on the Accuracy of Wearable Heart Rate Monitors During Rest and Various Exercise Intensities.

Moghaddam M, Collins JP, Gardner CE, Rabel MC.

Sensors (Basel, Switzerland) · 2025-12-26

DOI: 10.3390/s26010176 ↗PubMed · 41516615 ↗Europe PMC · Recorded licence: cc by ↗

Abstract © the original authors, reproduced under the recorded open licence. Translations support reading; use the English record to check terminology and numerical results. Our methodological interpretation is separate from the authors’ conclusions.

MoveVitals editorial interpretation · educational content · no individual clinical review recorded

Sources checked 2026-11-01

Practical guides

Read in context

·Cohort study

Activity–stroke and heart attack curves differ by accelerometer processing method

Among 90,237 UK Biobank adults free of cardiovascular disease at baseline, followed until December 2022 for 1,298 strokes and 2,031 myocardial infarctions, the shape of the link between moderate-vigorous physical activity (MVPA) and each outcome depended on how the accelerometer data were processed. For stroke, hazard fell in a straight line only with the machine-learning metric; for myocardial infarction, two metrics gave a curved decline and activity counts a straight one. The abstract gives no hazard ratios, so it shows that methods disagree, not which one is right, and the findings are observational associations.

Preventive Medicine

In-depth explainersRead study →
·Validation study/review

Smartwatch data as forensic evidence: heart rate is best validated, the rest uneven

A systematic review and meta-analysis of studies on smartwatches from four major brands, framed around digital forensics, found that heart rate was both the most studied and the most accurate measure. Step count, distance, energy expenditure, activity classification and sleep were less consistently validated, and results varied by brand, protocol and reporting. The abstract gives no pooled numbers, and most studies were run in healthy people in laboratories, so it cannot say how a particular watch performs for a particular person in daily life.

Forensic Science International

In-depth explainersRead study →
·Overview of reviews

Activity trackers: about 1,800 more steps a day, but small effects on other outcomes

An umbrella review of 39 systematic reviews and meta-analyses, covering 163,992 participants, found that activity trackers were associated with more physical activity (SMD 0.3–0.6), equating to about 1,800 extra steps and 40 minutes more walking per day, and with a bodyweight reduction of about 1 kg. Effects on blood pressure, cholesterol, glycosylated haemoglobin, quality of life and pain were typically small and often non-significant. The abstract does not say what else came with the trackers in these programs or how much the reviews overlap, so the gains cannot be credited to the device alone.

The Lancet Digital Health

In-depth explainersRead study →
·Validation study/review

Seven sleep trackers: good at spotting sleep, weak on wake and sleep stages

In a sleep laboratory, 34 healthy young adults wore a subset of seven consumer sleep trackers for three nights. Against polysomnography every device detected sleep very well (sensitivity 0.93 or higher) but caught wake poorly (specificity 0.18–0.54), and five of the seven matched or beat research actigraphy (specificity 0.39). Sleep-stage estimates were inconsistent, and the participants were healthy adults aged 18 to 35 in a fixed 8-hour bed window, with each device tested in only 11 to 20 of them, so the results say little about people with sleep problems.

Sleep

In-depth explainersRead study →
Wearables & measurement →