Key takeaway
A scoping review of 10 studies of health care professionals found no physiological measure reliably associated with burnout or anxiety, though step count and time in bed were linked to depressive symptoms, and heart rate and heart rate variability to acute stress. The studies were few, short and small, so wearables for burnout prediction remain unproven.
Study design
Evidence review
Reading basis
Published abstract
Reading focus
Design & applicability
The research question
Burnout affects up to 60% of US medical students, residents, physicians and registered nurses, and an early warning from a wearable could help. The authors set out to identify physiological biomarkers of burnout that wearables can pick up, and to map the gaps in how wearables are used to predict burnout among health care professionals.
Who and how
Scoping review. The authors searched 11 databases, including MEDLINE, Embase, PsycInfo, the Cochrane Central Register of Controlled Trials, Web of Science, Scopus and CINAHL, on June 7, 2022, with no date limits. They included studies of anxiety, burnout, stress and depression in medical students, residents, physicians and nurses wearing a wearable device, and assessed bias with the Newcastle Ottawa Quality Assessment Form for Cohort Studies. The search yielded 505 papers, of which 10 (1.95%) were included.
What it found
The authors’ reported results. Read each estimate with its population and uncertainty.
- 1Of 10 included studies, most (n=9) used wrist-worn biosensors and most (n=8) were observational cohort studies, with a low risk of bias.
- 2No physiological measure was reliably associated with burnout or anxiety.
- 3Step count and time in bed were associated with depressive symptoms, and heart rate and heart rate variability were associated with acute stress.
- 4Studies rarely had long-term observation (for example 12 months or more) or large samples, and seldom combined wearable data with system-level information such as patient acuity. Reporting of device adherence and sampling frequency was often insufficient.
Limits & uncertainty
- 1Only 10 studies met the criteria, mostly observational and with small samples, so the review cannot say whether wearables predict burnout.
- 2The abstract does not report effect sizes, and different studies likely used different devices and measures, which the authors flag as a data-standardization problem.
- 3Poor reporting of device adherence and sampling frequency makes it hard to judge how much data the wearables actually captured.
- 4This reading is based on the abstract only.
What to take from it
Today's wearables can show how stress, sleep and activity are changing for you, but there is no validated wearable score that detects burnout. If work stress is affecting your mood, sleep or functioning, talking with a clinician or your employer's support service matters more than any device reading.
Reading your own data
The signals that tied to mental state here are the ones many wearables record: steps, time in bed, heart rate and HRV. Compare your own numbers on the same device across weeks, watching for sustained shifts such as less movement or more time in bed, and treat them as a prompt to check in with yourself, not a burnout diagnosis.
How to read this evidence
Check which designs were included, how searches and bias assessment were conducted, and the last search date. Publication date alone does not make the underlying evidence current.
Authors’ structured abstract English
The attributed English abstract is reproduced under the recorded open licence. It is source material, not a MoveVitals interpretation. The prepared analysis above separates the authors’ findings from our interpretation.
Background
The occupational burnout epidemic is a growing issue, and in the United States, up to 60% of medical students, residents, physicians, and registered nurses experience symptoms. Wearable technologies may provide an opportunity to predict the onset of burnout and other forms of distress using physiological markers.
Objective
This study aims to identify physiological biomarkers of burnout, and establish what gaps are currently present in the use of wearable technologies for burnout prediction among health care professionals (HCPs).
Methods
A comprehensive search of several databases was performed on June 7, 2022. No date limits were set for the search. The databases were Ovid: MEDLINE(R), Embase, Healthstar, APA PsycInfo, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, Web of Science Core Collection via Clarivate Analytics, Scopus via Elsevier, EBSCOhost: Academic Search Premier, CINAHL with Full Text, and Business Source Premier. Studies observing anxiety, burnout, stress, and depression using a wearable device worn by an HCP were included, with HCP defined as medical students, residents, physicians, and nurses. Bias was assessed using the Newcastle Ottawa Quality Assessment Form for Cohort Studies.
Results
The initial search yielded 505 papers, from which 10 (1.95%) studies were included in this review. The majority (n=9) used wrist-worn biosensors and described observational cohort studies (n=8), with a low risk of bias. While no physiological measures were reliably associated with burnout or anxiety, step count and time in bed were associated with depressive symptoms, and heart rate and heart rate variability were associated with acute stress. Studies were limited with long-term observations (eg, ≥12 months) and large sample sizes, with limited integration of wearable data with system-level information (eg, acuity) to predict burnout. Reporting standards were also insufficient, particularly in device adherence and sampling frequency used for physiological measurements.
Conclusions
With wearables offering promise for digital health assessments of human functioning, it is possible to see wearables as a frontier for predicting burnout. Future digital health studies exploring the utility of wearable technologies for burnout prediction should address the limitations of data standardization and strategies to improve adherence and inclusivity in study participation.
Sources & attribution
Wearable Technologies for Detecting Burnout and Well-Being in Health Care Professionals: Scoping Review.
Barac M, Scaletty S, Hassett LC, Stillwell A, Croarkin PE, Chauhan M, Chesak S, Bobo WV, Athreya AP, Dyrbye LN.
Journal of medical Internet research · 2024-06-25
DOI: 10.2196/50253 ↗PubMed · 38916948 ↗Europe PMC · Recorded licence: cc by ↗Abstract © the original authors, reproduced under the recorded open licence. Translations support reading; use the English record to check terminology and numerical results. Our methodological interpretation is separate from the authors’ conclusions.
MoveVitals editorial interpretation · educational content · no individual clinical review recorded
Sources checked 2026-11-01
Practical guides
Read in context
Activity–stroke and heart attack curves differ by accelerometer processing method
Among 90,237 UK Biobank adults free of cardiovascular disease at baseline, followed until December 2022 for 1,298 strokes and 2,031 myocardial infarctions, the shape of the link between moderate-vigorous physical activity (MVPA) and each outcome depended on how the accelerometer data were processed. For stroke, hazard fell in a straight line only with the machine-learning metric; for myocardial infarction, two metrics gave a curved decline and activity counts a straight one. The abstract gives no hazard ratios, so it shows that methods disagree, not which one is right, and the findings are observational associations.
Preventive Medicine
Smartwatch data as forensic evidence: heart rate is best validated, the rest uneven
A systematic review and meta-analysis of studies on smartwatches from four major brands, framed around digital forensics, found that heart rate was both the most studied and the most accurate measure. Step count, distance, energy expenditure, activity classification and sleep were less consistently validated, and results varied by brand, protocol and reporting. The abstract gives no pooled numbers, and most studies were run in healthy people in laboratories, so it cannot say how a particular watch performs for a particular person in daily life.
Forensic Science International
Activity trackers: about 1,800 more steps a day, but small effects on other outcomes
An umbrella review of 39 systematic reviews and meta-analyses, covering 163,992 participants, found that activity trackers were associated with more physical activity (SMD 0.3–0.6), equating to about 1,800 extra steps and 40 minutes more walking per day, and with a bodyweight reduction of about 1 kg. Effects on blood pressure, cholesterol, glycosylated haemoglobin, quality of life and pain were typically small and often non-significant. The abstract does not say what else came with the trackers in these programs or how much the reviews overlap, so the gains cannot be credited to the device alone.
The Lancet Digital Health
Seven sleep trackers: good at spotting sleep, weak on wake and sleep stages
In a sleep laboratory, 34 healthy young adults wore a subset of seven consumer sleep trackers for three nights. Against polysomnography every device detected sleep very well (sensitivity 0.93 or higher) but caught wake poorly (specificity 0.18–0.54), and five of the seven matched or beat research actigraphy (specificity 0.39). Sleep-stage estimates were inconsistent, and the participants were healthy adults aged 18 to 35 in a fixed 8-hour bed window, with each device tested in only 11 to 20 of them, so the results say little about people with sleep problems.
Sleep