Key takeaway
This review of 158 publications on nine commercial wearable brands found that Fitbit, Apple Watch and Samsung appeared to measure steps accurately in laboratory settings, heart rate accuracy varied by brand, and no brand was accurate for energy expenditure. Most evidence was lab-based and concentrated on Fitbit, and device models change quickly.
Study design
Evidence review
Reading basis
Published abstract
Reading focus
Design & applicability
The research question
Millions of people trust wearables for steps, heart rate and calories, yet accuracy differs by brand and model. The authors reviewed the evidence on how valid and how reliable commercial wearables are for step count, heart rate and energy expenditure.
Who and how
Systematic review. The authors searched PubMed, Embase and SPORTDiscus for English-language articles up to May 2019 and excluded studies that did not name the device or did not test validity or reliability. General and special populations were both included. Validity meant criterion validity (against other measures) and construct validity; reliability meant intradevice and interdevice reliability. The abstract does not report a pooled statistic.
What it found
The authors’ reported results. Read each estimate with its population and uncertainty.
- 1158 publications on nine commercial wearable brands were included, and Fitbit was by far the most studied.
- 2In laboratory settings, Fitbit, Apple Watch and Samsung appeared to measure steps accurately.
- 3Heart rate accuracy was more variable: Apple Watch and Garmin were the most accurate, while Fitbit tended toward underestimation.
- 4For energy expenditure, no brand was accurate. The authors conclude that steps and heart rate are accurate in the lab, with differences by manufacturer and device type.
Limits & uncertainty
- 1Evidence is mostly laboratory-based, so accuracy during real daily life may be lower; the abstract does not report field results.
- 2Fitbit dominates the literature, so conclusions about other brands rest on fewer studies.
- 3Devices are redesigned constantly, so findings about earlier models may not apply to the one you wear. The abstract gives no pooled error figures. This reading is based on the abstract only.
What to take from it
Step counts from the main brands are a reasonable basis for tracking your own activity in a lab-like setting, and heart rate is better on some brands than others. Treat calorie burn numbers as rough guesses rather than precise targets.
Reading your own data
This is directly about the steps, heart rate and calorie numbers your watch or band shows. Stick with one device and compare your own trends over weeks rather than across brands, and do not use calorie estimates to set exact food targets.
How to read this evidence
Check which designs were included, how searches and bias assessment were conducted, and the last search date. Publication date alone does not make the underlying evidence current.
Authors’ structured abstract English
The attributed English abstract is reproduced under the recorded open licence. It is source material, not a MoveVitals interpretation. The prepared analysis above separates the authors’ findings from our interpretation.
Background
Consumer-wearable activity trackers are small electronic devices that record fitness and health-related measures.
Objective
The purpose of this systematic review was to examine the validity and reliability of commercial wearables in measuring step count, heart rate, and energy expenditure.
Methods
We identified devices to be included in the review. Database searches were conducted in PubMed, Embase, and SPORTDiscus, and only articles published in the English language up to May 2019 were considered. Studies were excluded if they did not identify the device used and if they did not examine the validity or reliability of the device. Studies involving the general population and all special populations were included. We operationalized validity as criterion validity (as compared with other measures) and construct validity (degree to which the device is measuring what it claims). Reliability measures focused on intradevice and interdevice reliability.
Results
We included 158 publications examining nine different commercial wearable device brands. Fitbit was by far the most studied brand. In laboratory-based settings, Fitbit, Apple Watch, and Samsung appeared to measure steps accurately. Heart rate measurement was more variable, with Apple Watch and Garmin being the most accurate and Fitbit tending toward underestimation. For energy expenditure, no brand was accurate. We also examined validity between devices within a specific brand.
Conclusions
Commercial wearable devices are accurate for measuring steps and heart rate in laboratory-based settings, but this varies by the manufacturer and device type. Devices are constantly being upgraded and redesigned to new models, suggesting the need for more current reviews and research.
Sources & attribution
Reliability and Validity of Commercially Available Wearable Devices for Measuring Steps, Energy Expenditure, and Heart Rate: Systematic Review.
Fuller D, Colwell E, Low J, Orychock K, Tobin MA, Simango B, Buote R, Van Heerden D, Luan H, Cullen K, Slade L, Taylor NGA.
JMIR mHealth and uHealth · 2020-09-08
DOI: 10.2196/18694 ↗PubMed · 32897239 ↗Europe PMC · Recorded licence: cc by ↗Abstract © the original authors, reproduced under the recorded open licence. Translations support reading; use the English record to check terminology and numerical results. Our methodological interpretation is separate from the authors’ conclusions.
MoveVitals editorial interpretation · educational content · no individual clinical review recorded
Sources checked 2026-11-01
Practical guides
Read in context
Activity–stroke and heart attack curves differ by accelerometer processing method
Among 90,237 UK Biobank adults free of cardiovascular disease at baseline, followed until December 2022 for 1,298 strokes and 2,031 myocardial infarctions, the shape of the link between moderate-vigorous physical activity (MVPA) and each outcome depended on how the accelerometer data were processed. For stroke, hazard fell in a straight line only with the machine-learning metric; for myocardial infarction, two metrics gave a curved decline and activity counts a straight one. The abstract gives no hazard ratios, so it shows that methods disagree, not which one is right, and the findings are observational associations.
Preventive Medicine
Smartwatch data as forensic evidence: heart rate is best validated, the rest uneven
A systematic review and meta-analysis of studies on smartwatches from four major brands, framed around digital forensics, found that heart rate was both the most studied and the most accurate measure. Step count, distance, energy expenditure, activity classification and sleep were less consistently validated, and results varied by brand, protocol and reporting. The abstract gives no pooled numbers, and most studies were run in healthy people in laboratories, so it cannot say how a particular watch performs for a particular person in daily life.
Forensic Science International
Activity trackers: about 1,800 more steps a day, but small effects on other outcomes
An umbrella review of 39 systematic reviews and meta-analyses, covering 163,992 participants, found that activity trackers were associated with more physical activity (SMD 0.3–0.6), equating to about 1,800 extra steps and 40 minutes more walking per day, and with a bodyweight reduction of about 1 kg. Effects on blood pressure, cholesterol, glycosylated haemoglobin, quality of life and pain were typically small and often non-significant. The abstract does not say what else came with the trackers in these programs or how much the reviews overlap, so the gains cannot be credited to the device alone.
The Lancet Digital Health
Seven sleep trackers: good at spotting sleep, weak on wake and sleep stages
In a sleep laboratory, 34 healthy young adults wore a subset of seven consumer sleep trackers for three nights. Against polysomnography every device detected sleep very well (sensitivity 0.93 or higher) but caught wake poorly (specificity 0.18–0.54), and five of the seven matched or beat research actigraphy (specificity 0.39). Sleep-stage estimates were inconsistent, and the participants were healthy adults aged 18 to 35 in a fixed 8-hour bed window, with each device tested in only 11 to 20 of them, so the results say little about people with sleep problems.
Sleep