Skip to content
Cardiovascular healthResearch article3 min read

Brazilian VO2max reference values from 18,189 treadmill tests, by age and sex

MoveVitals Editorial Collective · Study published · Reading updated

Original paper:Cardiorespiratory fitness data from 18,189 participants who underwent treadmill cardiopulmonary exercise testing in a Brazilian population. · PloS one · 2019 · Original paper ↗

Key takeaway

In 18,189 Brazilians without structural heart disease who did treadmill cardiopulmonary exercise tests, the 50th-percentile VO2max fell from 44.7 (men) and 36.3 (women) mL/kg/min at ages 20-29 to 28.4 and 22.3 at ages 60-69. The data come from one laboratory's records, and the abstract does not say why people were tested or how representative they are.

Study design

Research article

Reading basis

Published abstract

Reading focus

Design & applicability

The research question

Cardiorespiratory fitness is linked to lower risk of cardiovascular disease, death from any cause and cancer mortality, yet it is often estimated from formulas rather than measured. Reference values built from direct testing help people judge their own fitness. The authors set out to create such standards from treadmill cardiopulmonary exercise tests in a Brazilian population and compare them with existing data.

Who and how

Database study built from cardiopulmonary exercise testing reports at the Fleury laboratory. The final cohort was 18,189 individuals considered free of structural heart disease. Percentiles of maximal oxygen uptake (VO2max, in mL/kg/min) were determined for men and women across six age groups spanning 7 to 84 years, and compared with existing reference data from Norway and the United States. The abstract does not describe the treadmill protocol or why people were tested.

What it found

The authors’ reported results. Read each estimate with its population and uncertainty.

  1. 1
    Maximal oxygen uptake differed significantly between sexes and across age groups; the abstract gives no test statistics.
  2. 2
    Median (50th percentile) values for men fell from 44.7 mL/kg/min at ages 20-29 to 28.4 mL/kg/min at ages 60-69. For women they fell from 36.3 to 22.3 mL/kg/min over the same ages.
  3. 3
    In every age group, both Norwegian men and women had greater cardiorespiratory fitness than the cohorts from the United States and Brazil.

Limits & uncertainty

  1. 1
    People were tested at one laboratory for reasons the abstract does not give, so the percentiles may not match the general Brazilian population.
  2. 2
    The abstract states percentiles only for ages 20-29 and 60-69; values for the youngest and oldest groups and the number of people in each group are not reported there.
  3. 3
    The comparison with Norwegian and US data crosses different populations, and the abstract does not describe how those cohorts were tested, so the differences may not be only about fitness.
  4. 4
    Percentiles by age group compare different people at each age; they do not follow the same individuals as they age. This reading is based on the abstract only.

What to take from it

These percentiles show where a treadmill-measured VO2max sits for a given age and sex in a large Brazilian sample, and that fitness falls with age in both sexes. A watch estimate is not a lab test, so use these values only as a rough guide. What to do about low fitness or symptoms is a question for your clinician.

Reading your own data

If your watch or app gives a VO2max estimate, you can see roughly where it sits against these age and sex medians, but wearable estimates come from heart rate and pace models and can differ from treadmill testing. Compare with yourself first: use the same device, similar workouts and conditions, and watch the trend over weeks rather than one value. Brazilian lab percentiles may not match your own population.

How to read this evidence

The index does not establish a precise design. Read the methods before making causal claims; check population, comparator, outcomes and uncertainty in the source.

Authors’ structured abstract English

The attributed English abstract is reproduced under the recorded open licence. It is source material, not a MoveVitals interpretation. The prepared analysis above separates the authors’ findings from our interpretation.

Purpose

Cardiorespiratory fitness is inversely associated with a high risk of cardiovascular disease, all-cause mortality, and mortality attributable to various cancers. It is often estimated indirectly using mathematical formulas for estimating oxygen uptake. Cardiopulmonary exercise testing, especially oxygen uptake, represents the "gold standard" for assessing exercise capacity. The purpose of this report was to develop reference standards for exercise capacity by establishing cardiorespiratory fitness values derived from cardiopulmonary exercise testing in a Brazilian population. We focused on oxygen uptake standards and compared the maximal oxygen uptake [mLO2·kg-1·min-1] values with those in the existing literature.

Methods

A database was constructed using reports from cardiopulmonary exercise testing performed at Fleury laboratory. The final cohort included 18,189 individuals considered to be free of structural heart disease. Percentiles of maximal oxygen uptake for men and women were determined for six age groups between 7 and 84 years. We compared the values with existing reference data from patients from Norway and the United States.

Results

There were significant differences in maximal oxygen uptake between sexes and across the age groups. In our cohort, the 50th percentile maximal oxygen uptake values for men and women decreased from 44.7 and 36.3 mLO2·kg-1·min-1 to 28.4 and 22.3 mLO2·kg-1·min-1 for patients aged 20-29 years to patients aged 60-69 years, respectively. For each age group, both Norwegian men and women had greater cardiorespiratory fitness than cohorts in the United States and Brazil.

Conclusion

To our knowledge, our analysis represents the largest reference data for cardiorespiratory fitness based on treadmill cardiopulmonary exercise testing. Our findings provide reference values of maximal oxygen uptake measurements from treadmill tests in Brazilian populations that are more accurate than previous standard values based on workload-derived estimations. This data may also add information to the global data used for the interpretation of cardiorespiratory fitness.

Sources & attribution

Cardiorespiratory fitness data from 18,189 participants who underwent treadmill cardiopulmonary exercise testing in a Brazilian population.

Rossi Neto JM, Tebexreni AS, Alves ANF, Smanio PEP, de Abreu FB, Thomazi MC, Nishio PA, Cuninghant IA.

PloS one · 2019-01-09

DOI: 10.1371/journal.pone.0209897 ↗PubMed · 30625200 ↗Europe PMC · Recorded licence: cc by ↗

Abstract © the original authors, reproduced under the recorded open licence. Translations support reading; use the English record to check terminology and numerical results. Our methodological interpretation is separate from the authors’ conclusions.

MoveVitals editorial interpretation · educational content · no individual clinical review recorded

Sources checked 2026-11-01

Practical guides

Read in context

·Observational meta-analysis

Disrupted daily rest-activity rhythm is linked to higher mortality in 109,365 people

Across seven observational studies with 109,365 participants, a weaker day-night activity contrast (lower relative amplitude) was associated with higher cardiovascular mortality (hazard ratio [HR] 1.50, 95% CI 1.13 to 1.98) and all-cause mortality (HR 1.46, 95% CI 1.27 to 1.68). The evidence base is small and observational, so it cannot show that improving the rhythm lowers risk, and illness may itself disturb the rhythm.

Journal of the American Heart Association

In-depth explainersRead study →
·Trial meta-analysis

Five exercise types lowered resting blood pressure, isometric training the most

Pooling 270 randomised trials with 15,827 participants, aerobic, resistance, combined, interval and isometric training all lowered resting blood pressure compared with non-intervention controls (P<0.001 for each), with the largest fall for isometric training: 8.24 mm Hg systolic and 4.00 mm Hg diastolic. The ranking between modes is partly indirect and the trials differ, so it is not a personal prescription.

British Journal of Sports Medicine

In-depth explainersRead study →
·Randomised trial

A salt substitute lowered stroke, major cardiovascular events and death in rural China

In 20,995 people in 600 rural Chinese villages who had a history of stroke or were 60 or older with high blood pressure, a salt substitute (75% sodium chloride, 25% potassium chloride) lowered the stroke rate versus regular salt over a mean 4.74 years: 29.14 versus 33.65 events per 1000 person-years (rate ratio 0.86, 95% CI 0.77 to 0.96; P = 0.006). Death was also lower (rate ratio 0.88) and serious hyperkalemia events were not significantly higher, but the trial was open-label and set in rural China.

The New England Journal of Medicine

In-depth explainersRead study →
·Validation study/review

Apple Watch irregular-pulse alerts were rare; 34% of those tested had atrial fibrillation

Among 419,297 Apple Watch users with no known atrial fibrillation (AF), 0.52% received an irregular-pulse alert, and 34% of the 450 who returned a usable ECG patch had AF (97.5% CI 29 to 39). Alerts that coincided with patch recording matched AF with a positive predictive value of 0.84 (95% CI 0.76 to 0.92), but only 20.8% of alerted people returned a patch and nobody without an alert was monitored, so a quiet watch does not rule AF out.

The New England Journal of Medicine

In-depth explainersRead study →
Cardiovascular health →