Skip to content
Wearables & measurementValidation study/review3 min read

The IPAQ questionnaire was a poor measure of sitting and activity in older adults

MoveVitals Editorial Collective · Study published · Reading updated

Original paper:Reliability and validity of the international physical activity questionnaire compared to calibrated accelerometer cut-off points in the quantification of sedentary behaviour and physical activity in older adults. · PloS one · 2018 · Original paper ↗

Key takeaway

In 89 older adults (average age 73.7 years), the International Physical Activity Questionnaire (IPAQ) showed weak reliability and poor validity for sitting time and moderate-vigorous activity against a thigh-worn accelerometer, and classified behaviour correctly only 2% of the time. The sample was small, so the finding is a caution about questionnaires rather than a precise error estimate.

Study design

Validation study/review

Reading basis

Published abstract

Reading focus

Reference & error

The research question

Questionnaires are a cheap way to estimate how much older people sit and move, but they depend on memory. The authors tested how repeatable the IPAQ is, and how well it agrees with an accelerometer, for sedentary behaviour and moderate-vigorous physical activity, and whether men and women differ.

Who and how

Validation study of 89 participants (73.7 ± 6.3 years, 54% female). Each completed the IPAQ, wore a thigh-mounted triaxial accelerometer (GeneActiv Original) for seven consecutive days, and then completed the IPAQ a second time. Reliability compared the two questionnaires; validity compared the IPAQ with accelerometer cut-off points for total sedentary behaviour, 10-minute moderate-vigorous activity (bouts of at least 10 continuous minutes) and sporadic moderate-vigorous activity (bouts under 10 minutes). Sex differences were examined. The abstract does not report the correlation values.

What it found

The authors’ reported results. Read each estimate with its population and uncertainty.

  1. 1
    The IPAQ showed weak reliability for total sitting time (hours per week) and for 10-minute moderate-vigorous activity.
  2. 2
    Concurrent validity against the accelerometer was poor for total sitting time and 10-minute moderate-vigorous activity, but not for sporadic moderate-vigorous activity.
  3. 3
    The IPAQ classified participants' physical behaviour correctly only 2% of the time.
  4. 4
    Sex differences appeared only for the correlation slope of IPAQ 10-minute moderate-vigorous activity reliability.

Limits & uncertainty

  1. 1
    With 89 participants, estimates of agreement are imprecise and subgroup comparisons by sex have little power.
  2. 2
    The accelerometer is itself an estimate, and its cut-off points define what counts as sedentary or moderate-vigorous.
  3. 3
    The abstract gives no correlation coefficients or confidence intervals, so the size of the disagreement is unclear.
  4. 4
    This reading is based on the abstract only.

What to take from it

If you or a relative are asked to recall weekly sitting and exercise time, expect large errors. The authors concluded that the IPAQ is not suitable for assessing older adults' habitual physical behaviour. A worn sensor is likely to give a more reliable picture than memory.

Reading your own data

For an older adult, sensor-based daily steps or active minutes from the same wrist or thigh device are a better basis for trends than estimating from memory. Compare weeks using the same device and wear pattern.

How to read this evidence

Agreement is specific to the device, firmware, reference, population and setting. Correlation is not agreement, and validating a metric is not proof of diagnostic or treatment benefit.

Authors’ structured abstract English

The attributed English abstract is reproduced under the recorded open licence. It is source material, not a MoveVitals interpretation. The prepared analysis above separates the authors’ findings from our interpretation.

Background

The aim was to determine the reliability and validity of IPAQ measured sedentary behaviour (SB) and moderate-vigorous physical activity (MVPA) in older persons whilst examining any sex differences in reliability and validity results.

Method

89 participants (73.7 ± 6.3 years, 54% female) completed the IPAQ. Participants were fitted with a thigh mounted triaxial accelerometer (GeneActiv Original) for seven consecutive days and subsequently completed a second IPAQ.

Results

IPAQ showed weak reliability qualities for Total SB (h·week-1) and 10 minute MVPA (accumulated in bouts ≥ 10 continuous minutes, h·week-1). IPAQ had poor concurrent validity qualities for Total SB, 10 minute MVPA, but not Sporadic MVPA (accumulated in bouts < 10 continuous minutes, h·week-1). IPAQ only categorised participant physical behaviour classification correctly 2% of the time. Sex differences were only present for the correlation slope of IPAQ 10 minute MVPA reliability measures.

Conclusion

Our data suggests that the IPAQ is not suitable for assessing older adults habitual physical behaviour.

Sources & attribution

Reliability and validity of the international physical activity questionnaire compared to calibrated accelerometer cut-off points in the quantification of sedentary behaviour and physical activity in older adults.

Ryan DJ, Wullems JA, Stebbings GK, Morse CI, Stewart CE, Onambele-Pearson GL.

PloS one · 2018-04-19

DOI: 10.1371/journal.pone.0195712 ↗PubMed · 29672534 ↗Europe PMC · Recorded licence: cc by ↗

Abstract © the original authors, reproduced under the recorded open licence. Translations support reading; use the English record to check terminology and numerical results. Our methodological interpretation is separate from the authors’ conclusions.

MoveVitals editorial interpretation · educational content · no individual clinical review recorded

Sources checked 2026-11-01

Practical guides

Read in context

·Cohort study

Activity–stroke and heart attack curves differ by accelerometer processing method

Among 90,237 UK Biobank adults free of cardiovascular disease at baseline, followed until December 2022 for 1,298 strokes and 2,031 myocardial infarctions, the shape of the link between moderate-vigorous physical activity (MVPA) and each outcome depended on how the accelerometer data were processed. For stroke, hazard fell in a straight line only with the machine-learning metric; for myocardial infarction, two metrics gave a curved decline and activity counts a straight one. The abstract gives no hazard ratios, so it shows that methods disagree, not which one is right, and the findings are observational associations.

Preventive Medicine

In-depth explainersRead study →
·Validation study/review

Smartwatch data as forensic evidence: heart rate is best validated, the rest uneven

A systematic review and meta-analysis of studies on smartwatches from four major brands, framed around digital forensics, found that heart rate was both the most studied and the most accurate measure. Step count, distance, energy expenditure, activity classification and sleep were less consistently validated, and results varied by brand, protocol and reporting. The abstract gives no pooled numbers, and most studies were run in healthy people in laboratories, so it cannot say how a particular watch performs for a particular person in daily life.

Forensic Science International

In-depth explainersRead study →
·Overview of reviews

Activity trackers: about 1,800 more steps a day, but small effects on other outcomes

An umbrella review of 39 systematic reviews and meta-analyses, covering 163,992 participants, found that activity trackers were associated with more physical activity (SMD 0.3–0.6), equating to about 1,800 extra steps and 40 minutes more walking per day, and with a bodyweight reduction of about 1 kg. Effects on blood pressure, cholesterol, glycosylated haemoglobin, quality of life and pain were typically small and often non-significant. The abstract does not say what else came with the trackers in these programs or how much the reviews overlap, so the gains cannot be credited to the device alone.

The Lancet Digital Health

In-depth explainersRead study →
·Validation study/review

Seven sleep trackers: good at spotting sleep, weak on wake and sleep stages

In a sleep laboratory, 34 healthy young adults wore a subset of seven consumer sleep trackers for three nights. Against polysomnography every device detected sleep very well (sensitivity 0.93 or higher) but caught wake poorly (specificity 0.18–0.54), and five of the seven matched or beat research actigraphy (specificity 0.39). Sleep-stage estimates were inconsistent, and the participants were healthy adults aged 18 to 35 in a fixed 8-hour bed window, with each device tested in only 11 to 20 of them, so the results say little about people with sleep problems.

Sleep

In-depth explainersRead study →
Wearables & measurement →