MoveVitals 编辑部 · 研究发表 · 解读更新

原文:Wireless Home Blood Pressure Monitoring With Health Coaching for Hypertension Management at a Federally Qualified Health Center: Pilot Randomized Controlled Feasibility and Acceptability Study. · JMIR formative research · 2026 · 论文原文 ↗

先看重点

在联邦合格健康中心进行的6个月试点中,纳入分析的无线组86%(63/73)上传了多次读数,60名问卷应答者中95%(n=57)认为设备易于使用。血压结果仅为探索性且未设计足够把握度,各组分配人数也未保留,因此无法判断疗效。

证据类型

随机对照试验

解读依据

公开摘要

阅读重点

对照与不确定性

研究在问什么

仅约一半高血压成人血压得到控制,低收入和少数族裔人群差距更大。无线家庭监测可能有帮助,但在以西班牙裔为主的医疗资源不足人群中证据很少。作者主要检验无线监测在这一人群中是否可行、能否被接受。

研究了谁,如何研究

随机对照试点试验,共6个月,嵌套于圣迭戈“无心脏病与卒中区”项目,涉及3个联邦合格健康中心网络。纳入18岁及以上血压未控制或新诊断的高血压患者(血压不低于140/90 mm Hg),按1:1简单随机分配至无线监测组(蓝牙血压计和蜂窝网络集线器,健康教练每周查看上传的汇总)或普通家庭监测组(纸质记录)。两组均接受标准化健康指导。可行性为预期210次读数中被上传的比例,可接受性为无线组治疗后的满意度问卷。血压比较为探索性分析,仅限测量次数超过2次的参与者。

主要发现

以下为作者报告的结果。数字须连同人群和不确定性一起阅读。

  1. 1
    316名入组者中290名(92%)符合条件,200名(63%)纳入分析:无线组73名,常规组127名。平均年龄61岁(标准差9.1),女性占57%(115/200),51%(n=102)为西班牙裔。
  2. 2
    无线组86%(63/73)上传了多次读数(平均160.6,标准差129.1),占上传者预期读数的76.2%(160/210),占全部73人的66%;常规组仅5%(7/127)交回纸质记录。
  3. 3
    60名应答者(应答率82.2%)中,95%(n=57)同意或非常同意设备易于设置和使用。
  4. 4
    两组6个月时组内血压均显著下降(P <.001)。收缩压<140 mm Hg者无线组为63%(46/73),常规组为74%(94/127)(P =.08;校正比值比,常规组对无线组,1.6,95%置信区间0.78-3.4;P =.19),这不能证明两种方式等效。

局限与不确定性

  1. 1
    仅200名随机入组者被分析,各组分配人数未保留,因此无法估计全部随机入组者的可行性。
  2. 2
    分析限于测量次数超过2次的参与者,且常规组(127名)远多于无线组(73名),可能使比较产生偏倚。
  3. 3
    可接受性仅来自无线组60名应答者的问卷,没有对照组。
  4. 4
    作者说明血压比较未设计足够把握度;本解读仅基于摘要。

对日常健康的启示

在社区医疗中心,无线血压计对不少人是可行的,多数应答者觉得易用。但研究没有说明它降压效果是否优于或不如纸质记录。血压治疗的调整应由你和医生决定。

如何联系自己的数据

如果你使用蓝牙血压计,自动同步的定期读数正是这项试点所检验的数据。请使用同一台血压计、同样的姿势和时间,向医生展示每周平均值和趋势,而不是单次读数。

如何理解这类证据

随机分组有助于因果推断,仍须检查分配、盲法、失访、随访时间和具体对照;标为随机试验不自动意味着高确定性。

作者的结构化摘要 English

以下英文摘要按记录的开放许可转载,属于作者原始材料,不是 MoveVitals 的解读。上方已提供研究解读,分别说明作者结果与本站解释;重要结论可直接核对原文。

Background

Only approximately half of adults with hypertension, a leading cardiovascular risk factor, achieve blood pressure (BP) control, with persistent disparities among low-income and minority populations. Wireless home BP monitoring (HBPM) with remote patient monitoring can improve BP control, but evidence is limited in medically underserved, predominantly Hispanic populations served by federally qualified health centers (FQHCs).

Objective

The primary objective was to evaluate the feasibility and acceptability of wireless HBPM among predominantly Hispanic adults with hypertension receiving FQHC care. Comparing BP outcomes between wireless and conventional HBPM was a secondary exploratory objective.

Methods

We conducted a 6-month, 2-arm randomized controlled pilot feasibility and acceptability trial nested within the San Diego: Heart Attack and Stroke Free Zone program. Adults aged ≥18 years with uncontrolled or newly diagnosed hypertension (BP ≥140/90 mm Hg) were enrolled across 3 FQHC networks and randomized 1:1 by unrestricted simple randomization to wireless HBPM (Bluetooth cuff and cellular hub; weekly transmitted summaries reviewed by health coaches) or standard HBPM (home monitor with paper log). Both arms received standardized health coaching. The primary outcomes were feasibility (proportion of 210 expected BP readings transmitted) and acceptability (postintervention satisfaction survey in the wireless arm). Exploratory analyses compared BP outcomes between arms among participants with >2 BP measurements.

Results

Of 316 recruited participants, 290 (92%) were eligible, and 200 (63%) were analyzed (wireless: n=73, 23%; and standard: n=127, 40%); arm-level allocation counts were not retained. The mean age was 61 years (SD 9.1), 57% (115/200) were women, and 51% (n=102) self-identified as Hispanic, with no significant baseline differences between arms. Among analyzed wireless-arm participants, 86% (63/73) transmitted multiple readings (mean 160.6, SD 129.1) over 6 months, corresponding to 76.2% (160/210) of expected readings among transmitting participants and 66% across all 73; only 5% (7/127) of standard-arm participants returned paper logs. Of 60 respondents (82.2% response rate), 95% (n=57) agreed or strongly agreed that the device was easy to set up and use. Both arms showed significant within-arm BP reductions at 6 months ( P <.001). At 6 months, 63% (46/73) of the wireless arm and 74% (94/127) of the standard arm achieved systolic BP <140 mm Hg ( P =.08; adjusted odds ratio, standard vs wireless, 1.6, 95% CI 0.78-3.4; P =.19). These exploratory comparisons were not powered and do not constitute evidence of equivalence.

Conclusions

Among analyzed participants, wireless HBPM was feasible, and survey respondents reported high acceptability in a medically underserved, predominantly Hispanic FQHC population. Feasibility among all randomized participants could not be estimated because arm-level allocation counts were not retained. The absence of a between-arm difference in BP control is not evidence of equivalence because this pilot was not powered to compare clinical effectiveness; the BP findings are hypothesis generating.

来源与署名

Wireless Home Blood Pressure Monitoring With Health Coaching for Hypertension Management at a Federally Qualified Health Center: Pilot Randomized Controlled Feasibility and Acceptability Study.

Magalit N, Moran R, Narezkina A, Patrick K, DeMaria A.

JMIR formative research · 2026-10-22

DOI: 10.2196/100115 ↗PubMed · 42912953 ↗Europe PMC · 记录的开放许可: cc by ↗

摘要版权归原作者,依据来源记录的开放许可转载。中文译文辅助阅读,英文摘要用于核对术语与具体数值;本站的方法学解释与作者结论分别呈现。

MoveVitals 编辑解读 · 健康教育内容 · 未记录个人临床审阅

来源核验日期 2026-11-01

实用健康指南

放在一起读

·观察研究荟萃分析

昼夜活动节律紊乱与更高的死亡风险相关(109,365人)

在7项观察性研究、共109,365名参与者中,昼夜活动对比较弱(相对振幅较低)与更高的心血管死亡风险(风险比[HR]1.50,95%置信区间1.13至1.98)和全因死亡风险(HR 1.46,95%置信区间1.27至1.68)相关。证据基础小,又是观察性的,不能说明改善节律就能降低风险,疾病本身也可能扰乱节律。

Journal of the American Heart Association

重点论文精讲阅读论文 →
·随机试验荟萃分析

五类运动都降低了静息血压,等长训练降幅最大

汇总270项随机试验、共15,827名参与者的结果,有氧、抗阻、联合、间歇和等长训练与无干预对照组相比都降低了静息血压(各P<0.001),其中等长训练降幅最大:收缩压下降8.24 mm Hg,舒张压下降4.00 mm Hg。各方式之间的排序部分来自间接比较,各试验也不尽相同,所以排序不是个人的运动处方。

British Journal of Sports Medicine

重点论文精讲阅读论文 →
·随机对照试验

盐替代品使中国农村高危人群的卒中、主要心血管事件和死亡率下降

在中国农村600个村庄、20,995名有卒中史或年龄在60岁及以上且有高血压的人中,使用盐替代品(氯化钠75%、氯化钾25%)的卒中发生率低于普通盐:平均随访4.74年,每1000人年29.14次对33.65次(率比0.86,95%置信区间0.77至0.96;P=0.006)。死亡也更低(率比0.88),严重高钾血症事件没有显著增多,但试验为开放标签设计,且在中国农村开展。

The New England Journal of Medicine

重点论文精讲阅读论文 →
·测量验证研究/综述

智能手表脉搏不规则提醒较少见,做贴片检查者34%确有房颤

在419,297名没有已知心房颤动(房颤)的苹果手表用户中,0.52%收到脉搏不规则提醒;返还可用心电贴片的450人中,34%确认有房颤(97.5%置信区间29至39)。提醒发出时恰有贴片记录的,通知的阳性预测值为0.84(95%置信区间0.76至0.92),但收到提醒者中仅20.8%返还了贴片,没有收到提醒的人未被监测,所以手表没有提醒并不能排除房颤。

The New England Journal of Medicine

重点论文精讲阅读论文 →
心血管健康 →