跳到正文
心血管健康研究论文3 分钟阅读

腕戴设备测得的静息心率夜间更低,03:00至07:00最低

MoveVitals 编辑部 · 研究发表 · 解读更新

原文:Measure by measure: Resting heart rate across the 24-hour cycle. · PLOS digital health · 2023 · 论文原文 ↗

先看重点

433名健康人佩戴腕式设备最长3个月,静息心率平均值白天为54.5次/分、夜间为50.5次/分,在03:00至07:00最低;多数人在静止4分钟后心率趋于稳定。样本是健康志愿者,研究由Google资助。

证据类型

研究论文

解读依据

公开摘要

阅读重点

方法与适用范围

研究在问什么

静息心率是疾病和死亡风险的重要指标,但目前没有公认的定义和测量规则,而腕部传感器已能在大量人群中连续记录心率,这一点就显得更重要。研究者提出静息心率的工作定义,并给出一种利用腕部光电容积脉搏波(PPG)在24小时周期内准确测量它的方法。

研究了谁,如何研究

观察性设备研究。433名健康人佩戴腕式设备,用光电容积脉搏波(PPG)测量活动和心率,最长3个月。记录静止时的心率,并确定心率稳定所需的静止时长。将每个24小时周期内的最低心率视为真正的静息心率,观察其出现在一天中的哪个时段,同时评估静止时心率在一天内的变化。样本还按每日活动水平(MET四分位)分成亚组分析。摘要未给出参与者的年龄、性别和设备品牌。

主要发现

以下为作者报告的结果。数字须连同人群和不确定性一起阅读。

  1. 1
    获得了足够数据的天数为19,242天、夜晚为18,520个。
  2. 2
    多数人静止4分钟后心率趋于稳定。
  3. 3
    静息心率平均值(标准差)白天为54.5(8.0)次/分,夜间为50.5(7.6)次/分;作者称夜间显著更低,但摘要没有给出P值。
  4. 4
    静息心率在活动量最少的人群(MET最低四分位)中最高。
  5. 5
    静止时的心率呈现昼夜节律,多数人的最低值出现在03:00至07:00。

局限与不确定性

  1. 1
    研究由Google资助。摘要没有说明设备型号,也没有与心电图比较,腕部传感器的准确性是被当作已知前提的。
  2. 2
    433名参与者都是健康人,摘要未报告他们的年龄、性别和健康状况,所以白天54.5次/分、夜间50.5次/分不能当作患者或其他人群的常模。
  3. 3
    作者把每个24小时周期内的最低心率定义为真正的静息心率;静止4分钟对多数人适用,但并非所有人。摘要没有说明夜间最低值有多少反映的是睡眠而不是普通休息。
  4. 4
    摘要未报告任何健康结局,无法说明哪种定义最能预测风险。本文解读仅基于摘要。

对日常健康的启示

手表给出的静息心率取决于测量的时间和方式:夜间数值低于白天,最低值出现在03:00至07:00。手动测一次的话,先静坐至少4分钟。这些平均值描述的是一组健康人,并不是你的目标值;如果出现异常或持续的变化,值得告诉医生。

如何联系自己的数据

先弄清你的设备如何定义静息心率(夜间最低值、白天静息最低值,还是平均值),并且只比较同类数据:同一设备、同一定义、同一时间段。这项研究中白天和夜间的数值不同(白天54.5,夜间50.5),所以不要混在一起比较。看数周内的趋势,另外注意活动量最少的人群静息心率最高。

如何理解这类证据

索引未明确确定具体研究设计,应先读方法;核对人群、对照、结局和不确定性,再判断能否作因果解释。

作者的结构化摘要 English

以下英文摘要按记录的开放许可转载,属于作者原始材料,不是 MoveVitals 的解读。上方已提供研究解读,分别说明作者结果与本站解释;重要结论可直接核对原文。

Background

Photoplethysmography (PPG) sensors, typically found in wrist-worn devices, can continuously monitor heart rate (HR) in large populations in real-world settings. Resting heart rate (RHR) is an important biomarker of morbidities and mortality, but no universally accepted definition nor measurement criteria exist. In this study, we provide a working definition of RHR and describe a method for accurate measurement of this biomarker, recorded using PPG derived from wristband measurement across the 24-hour cycle.

Methods

433 healthy subjects wore a wrist device that measured activity and HR for up to 3 months. HR during inactivity was recorded and the duration of inactivity needed for HR to stabilise was ascertained. We identified the lowest HR during each 24-hour cycle (true RHR) and examined the time of day or night this occurred. The variation of HR during inactivity through the 24-hour cycle was also assessed. The sample was also subdivided according to daily activity levels for subset analysis.

Findings

Adequate data was obtained for 19,242 days and 18,520 nights. HR stabilised in most subjects after 4 minutes of inactivity. Mean (SD) RHR for the sample was 54.5 (8.0) bpm (day) and 50.5 (7.6) bpm (night). RHR values were highest in the least active group (lowest MET quartile). A circadian variation of HR during inactivity was confirmed, with the lowest values being between 0300 and 0700 hours for most subjects.

Interpretation

RHR measured using a PPG-based wrist-worn device is significantly lower at night than in the day, and a circadian rhythm of HR during inactivity was confirmed. Since RHR is such an important health metric, clarity on the definition and measurement methodology used is important. For most subjects, a minimum rest time of 4 minutes provides a reliable measurement of HR during inactivity and true RHR in a 24-hour cycle is best measured between 0300 and 0700 hours. Funding: This study was funded by Google.

来源与署名

Measure by measure: Resting heart rate across the 24-hour cycle.

Speed C, Arneil T, Harle R, Wilson A, Karthikesalingam A, McConnell M, Phillips J.

PLOS digital health · 2023-04-28

DOI: 10.1371/journal.pdig.0000236 ↗PubMed · 37115739 ↗Europe PMC · 记录的开放许可: cc by ↗

摘要版权归原作者,依据来源记录的开放许可转载。中文译文辅助阅读,英文摘要用于核对术语与具体数值;本站的方法学解释与作者结论分别呈现。

MoveVitals 编辑解读 · 健康教育内容 · 未记录个人临床审阅

来源核验日期 2026-11-01

实用健康指南

放在一起读

·观察研究荟萃分析

昼夜活动节律紊乱与更高的死亡风险相关(109,365人)

在7项观察性研究、共109,365名参与者中,昼夜活动对比较弱(相对振幅较低)与更高的心血管死亡风险(风险比[HR]1.50,95%置信区间1.13至1.98)和全因死亡风险(HR 1.46,95%置信区间1.27至1.68)相关。证据基础小,又是观察性的,不能说明改善节律就能降低风险,疾病本身也可能扰乱节律。

Journal of the American Heart Association

重点论文精讲阅读论文 →
·随机试验荟萃分析

五类运动都降低了静息血压,等长训练降幅最大

汇总270项随机试验、共15,827名参与者的结果,有氧、抗阻、联合、间歇和等长训练与无干预对照组相比都降低了静息血压(各P<0.001),其中等长训练降幅最大:收缩压下降8.24 mm Hg,舒张压下降4.00 mm Hg。各方式之间的排序部分来自间接比较,各试验也不尽相同,所以排序不是个人的运动处方。

British Journal of Sports Medicine

重点论文精讲阅读论文 →
·随机对照试验

盐替代品使中国农村高危人群的卒中、主要心血管事件和死亡率下降

在中国农村600个村庄、20,995名有卒中史或年龄在60岁及以上且有高血压的人中,使用盐替代品(氯化钠75%、氯化钾25%)的卒中发生率低于普通盐:平均随访4.74年,每1000人年29.14次对33.65次(率比0.86,95%置信区间0.77至0.96;P=0.006)。死亡也更低(率比0.88),严重高钾血症事件没有显著增多,但试验为开放标签设计,且在中国农村开展。

The New England Journal of Medicine

重点论文精讲阅读论文 →
·测量验证研究/综述

智能手表脉搏不规则提醒较少见,做贴片检查者34%确有房颤

在419,297名没有已知心房颤动(房颤)的苹果手表用户中,0.52%收到脉搏不规则提醒;返还可用心电贴片的450人中,34%确认有房颤(97.5%置信区间29至39)。提醒发出时恰有贴片记录的,通知的阳性预测值为0.84(95%置信区间0.76至0.92),但收到提醒者中仅20.8%返还了贴片,没有收到提醒的人未被监测,所以手表没有提醒并不能排除房颤。

The New England Journal of Medicine

重点论文精讲阅读论文 →
心血管健康 →