À retenir
Across about 3.8 million nights from 192,500 female Galaxy Smartwatch users aged 20-65, time awake after sleep onset (WASO) was +11 minutes (+32%) higher at 60-64 years than at 20-24, with smaller differences in total sleep time (17 minutes or less). Users were watch owners tracked for one month, so the results may not represent all women.
Study design
Article de recherche
Reading basis
Published abstract
Reading focus
Design & applicability
Cette explication éditoriale existe en anglais, chinois simplifié et chinois traditionnel. Cette interface affiche la lecture en anglais.
Question de recherche
Sleep is known to change with age and around menopause, but large objective studies of women's sleep across the adult lifespan are scarce. The authors set out to measure how age relates to objectively measured sleep in women, using smartwatch data from five countries and a comparison group of men.
Population et méthode
Analysis of about 3.8 million nights from 192,500 female Galaxy Smartwatch users aged 20-65 in the United States, South Korea, Germany, France and the United Kingdom, each with at least seven nights of sleep data during March 2024. Linear mixed models examined age in relation to total sleep period duration (TSPD), total sleep time (TST) and wakefulness after sleep onset (WASO, log-transformed), adjusting for repeated measures per user, country, body mass index, weekday or weekend night and daily activity time. Ages 20-24 were the reference group. Separate models were run for men.
Résultats
The authors’ reported results. Read each estimate with its population and uncertainty.
- 1In women, WASO rose notably at midlife compared with ages 20-24: +5 minutes (+15%) at 50-54, +9 minutes (+25%) at 55-59 and +11 minutes (+32%) at 60-64.
- 2In men the corresponding increases were smaller: +3 minutes (+9%), +6 minutes (+16%) and +9 minutes (+27%).
- 3Differences in TSPD and TST were small: at most 5 minutes shorter for TSPD and at most 17 minutes shorter for TST than the reference group.
- 4The age patterns for TST and WASO were similar across the Western countries. In South Korea, TSPD and TST were shorter at all ages and WASO increases were visible from early adulthood.
Limites et incertitude
- 1Participants were Galaxy Smartwatch owners who wore the watch for at least seven nights in one month (March 2024), a self-selected group that may differ from women generally.
- 2Smartwatch sleep measures are estimates, not the polysomnography gold standard, and the abstract does not report how accurately the watch detects wakefulness.
- 3The comparison is across ages at one time point, not women followed over their lives, and the abstract does not record menopausal status or sleep complaints; this reading is based on the abstract only.
Mise en perspective
A slightly longer time awake in the night after age 50 appears common among women wearing smartwatches, while total sleep time differed little. The authors suggest earlier identification of sleep problems in this life stage as part of health counseling. If sleep concerns you, discuss it with your clinician instead of relying on watch numbers.
Vos données
WASO from a wrist device is a rough estimate, so watch your own trend over weeks on the same device rather than a single night. Differences of a few minutes are within what everyday variation and device error could produce.
Comprendre ce type de preuve
The index does not establish a precise design. Read the methods before making causal claims; check population, comparator, outcomes and uncertainty in the source.
Résumé structuré des auteurs English
Le résumé original en anglais est reproduit avec attribution sous la licence ouverte indiquée. Il s’agit d’une source, pas d’une interprétation MoveVitals. L’analyse préparée figure ci-dessus ; vérifiez les conclusions importantes dans la source.
Study objectives
To evaluate associations between age and objectively measured sleep in women.
Materials and methods
We analyzed ~3.8 million nights' data from 192 500 female Galaxy Smartwatch users aged 20-65 years (United States, South Korea, Germany, France, and the United Kingdom) with at least seven nights' sleep data during March 2024. We evaluated associations between age and total sleep period duration (TSPD), total sleep time (TST), and wakefulness after sleep onset (WASO; log-transformed) using linear mixed models, adjusting for repeated user measures, country, body mass index, weekday/weekend night, and daily activity time. Reference group was age 20-24 years. Separate models were run for a comparison group of men.
Results
In women WASO increased notably at midlife; average increases of +5 mins (+15%) for 50-54 years, +9 minutes (+25%) for 55-59 years, and +11 minutes (+32%) for 60-64 years vs. reference group (corresponding increases in men were +3 minutes [+9%], +6 minutes [+16%], and +9 minutes [+27%]). Compared with the reference group, age differences in TSPD and TST were ≤5 minutes less and ≤17 minutes less, respectively. Effects of age on TST and WASO were similar across Western countries; in South Korea, TSPD and TST were shorter across all ages, while increases in WASO were apparent from early adulthood.
Conclusions
A pronounced increase in WASO was seen in women at midlife. Women in this stage of life could benefit from early identification and tailored interventions to improve their sleep as part of overall health counseling.
Sources et attribution
Sleep pattern differences in women at midlife: a large-scale multi-country smartwatch study (SONAR).
Soares CN, Dinkel-Keuthage C, Baker FC, Kim M, Lee J, Dorey J, Frenz AK, Lee D, Caetano C, Moeller C, Schoof N, Kramer F, Bolinger E, Graziano Custodio M, Choi R, Kanady J, Maki PM.
Sleep · 2026-10-01
DOI: 10.1093/sleep/zsag197 ↗PubMed · 42518248 ↗Europe PMC · Licence indiquée: cc by ↗Abstract © the original authors, reproduced under the recorded open licence. Translations support reading; use the English record to check terminology and numerical results. Our methodological interpretation is separate from the authors’ conclusions.
Interprétation éditoriale MoveVitals · contenu éducatif · aucune évaluation clinique individuelle enregistrée
Sources vérifiées 2026-11-01
Guides pratiques
À lire ensemble
Activity–stroke and heart attack curves differ by accelerometer processing method
Among 90,237 UK Biobank adults free of cardiovascular disease at baseline, followed until December 2022 for 1,298 strokes and 2,031 myocardial infarctions, the shape of the link between moderate-vigorous physical activity (MVPA) and each outcome depended on how the accelerometer data were processed. For stroke, hazard fell in a straight line only with the machine-learning metric; for myocardial infarction, two metrics gave a curved decline and activity counts a straight one. The abstract gives no hazard ratios, so it shows that methods disagree, not which one is right, and the findings are observational associations.
Preventive Medicine
Smartwatch data as forensic evidence: heart rate is best validated, the rest uneven
A systematic review and meta-analysis of studies on smartwatches from four major brands, framed around digital forensics, found that heart rate was both the most studied and the most accurate measure. Step count, distance, energy expenditure, activity classification and sleep were less consistently validated, and results varied by brand, protocol and reporting. The abstract gives no pooled numbers, and most studies were run in healthy people in laboratories, so it cannot say how a particular watch performs for a particular person in daily life.
Forensic Science International
Activity trackers: about 1,800 more steps a day, but small effects on other outcomes
An umbrella review of 39 systematic reviews and meta-analyses, covering 163,992 participants, found that activity trackers were associated with more physical activity (SMD 0.3–0.6), equating to about 1,800 extra steps and 40 minutes more walking per day, and with a bodyweight reduction of about 1 kg. Effects on blood pressure, cholesterol, glycosylated haemoglobin, quality of life and pain were typically small and often non-significant. The abstract does not say what else came with the trackers in these programs or how much the reviews overlap, so the gains cannot be credited to the device alone.
The Lancet Digital Health
Seven sleep trackers: good at spotting sleep, weak on wake and sleep stages
In a sleep laboratory, 34 healthy young adults wore a subset of seven consumer sleep trackers for three nights. Against polysomnography every device detected sleep very well (sensitivity 0.93 or higher) but caught wake poorly (specificity 0.18–0.54), and five of the seven matched or beat research actigraphy (specificity 0.39). Sleep-stage estimates were inconsistent, and the participants were healthy adults aged 18 to 35 in a fixed 8-hour bed window, with each device tested in only 11 to 20 of them, so the results say little about people with sleep problems.
Sleep