Aller au contenu
Capteurs et mesuresÉtude transversale3 min read

Why chronic disease patients in China use wearables: usefulness, ease, social influence

Collectif éditorial MoveVitals · Study published · Reading updated

Original paper:Bridging UTAUT and HBM: determinants of wearable device adoption among chronic disease patients. · Frontiers in public health · 2026 · Article original ↗

À retenir

In a survey of 432 Chinese patients with chronic diseases, expected usefulness, ease of use, social influence and facilitating conditions each positively predicted intention to use wearables, which in turn predicted actual use. This is a self-reported cross-sectional survey, so it shows associations in a model, not what would change behavior.

Study design

Étude transversale

Reading basis

Published abstract

Reading focus

Association & confounding

Cette explication éditoriale existe en anglais, chinois simplifié et chinois traditionnel. Cette interface affiche la lecture en anglais.

Question de recherche

Wearables could help patients manage chronic diseases, but it is not clear what makes patients adopt them. The authors combined two behavior frameworks, UTAUT (technology acceptance) and the Health Belief Model (HBM), to find which factors shape intention and use.

Population et méthode

Cross-sectional survey of Chinese patients with chronic diseases, yielding 432 valid responses. Partial least squares structural equation modeling (PLS-SEM) tested how latent variables affect behavioral intention and actual use of wearable devices, including a mediating role for performance expectancy and a moderating role for physical activity. The abstract does not report the survey dates, recruitment method or specific diseases.

Résultats

The authors’ reported results. Read each estimate with its population and uncertainty.

  1. 1
    Performance expectancy, effort expectancy, social influence and facilitating conditions each had a significant positive influence on behavioral intention, which in turn positively affected actual use.
  2. 2
    Perceived susceptibility and perceived severity worked indirectly: performance expectancy mediated their effects on intention, as it did for social influence.
  3. 3
    Physical activity did not moderate the link between performance expectancy and behavioral intention.
  4. 4
    The abstract gives no effect sizes or P values for these paths.

Limites et incertitude

  1. 1
    A one-time cross-sectional survey cannot show that these factors cause adoption, and answers are self-reported.
  2. 2
    Participants were Chinese patients with chronic diseases; the abstract does not say how they were recruited or which conditions were included, so the sample may not represent other groups.
  3. 3
    Intention and 'actual use' were both reported by patients rather than measured from device data, and no path coefficients appear in the abstract.
  4. 4
    Based on the abstract only.

Mise en perspective

Patients are more likely to use a wearable when they expect it to be useful, find it easy, and have support from people around them and the means to use it. Any device used for a chronic condition should still be discussed with your clinician.

Vos données

If you want a wearable to stick, choose one whose data you will actually look at and use the same device over time. Start with one or two measures you care about, such as steps or sleep, and review weekly trends.

Comprendre ce type de preuve

Measurements are taken in the same period. Direction and causation usually cannot be determined; symptoms can change behaviour as well as the reverse.

Résumé structuré des auteurs English

Le résumé original en anglais est reproduit avec attribution sous la licence ouverte indiquée. Il s’agit d’une source, pas d’une interprétation MoveVitals. L’analyse préparée figure ci-dessus ; vérifiez les conclusions importantes dans la source.

Objectives

Chronic diseases have emerged as a significant global health threat, making the effective management of these conditions crucial for improving patients' quality of life. Wearable devices, a significant innovation in digital healthcare, offer new solutions for managing the health of patients with chronic diseases. This study integrates the UTAUT model with the Health Belief Model (HBM) to analyze key factors influencing the adoption of wearable devices by patients with chronic diseases, aiming to provide a more comprehensive understanding of their behavioral patterns and motivations.

Methodology

A cross-sectional survey was conducted among Chinese patients with chronic diseases, yielding 432 valid responses. Partial Least Squares Structural Equation Modeling (PLS-SEM) was employed to construct the analytical model and examine the effects of latent variables on patients' behavioral intention and actual use of wearable devices.

Findings

The findings reveal that performance expectancy, effort expectancy, social influence, and facilitating conditions have a significant, positive influence on behavioral intention, which, in turn, positively affects actual use behavior. Performance expectancy mediates the relationships between social influence, perceived susceptibility, and perceived severity on behavioral intention. However, physical activity does not moderate the relationship between Performance Expectancy and Behavioral Intention.

Conclusion

Performance expectancy, effort expectancy, social influence, and facilitating conditions are identified as key determinants of patients with chronic diseases' adoption intention. Additionally, patients' perceived severity and perceived susceptibility indirectly influence their usage intention through performance expectancy.

Implications

These findings provide a theoretical foundation and practical guidance for optimizing the use of wearable devices in the management of chronic diseases. The study suggests that product development should focus on enhancing device performance, simplifying operational procedures, and strengthening social support systems.

Sources et attribution

Bridging UTAUT and HBM: determinants of wearable device adoption among chronic disease patients.

Guo Z, Chen SC.

Frontiers in public health · 2026-01-27

DOI: 10.3389/fpubh.2025.1687887 ↗PubMed · 41675082 ↗Europe PMC · Licence indiquée: cc by ↗

Abstract © the original authors, reproduced under the recorded open licence. Translations support reading; use the English record to check terminology and numerical results. Our methodological interpretation is separate from the authors’ conclusions.

Interprétation éditoriale MoveVitals · contenu éducatif · aucune évaluation clinique individuelle enregistrée

Sources vérifiées 2026-11-01

Guides pratiques

À lire ensemble

·Étude de cohorte

Activity–stroke and heart attack curves differ by accelerometer processing method

Among 90,237 UK Biobank adults free of cardiovascular disease at baseline, followed until December 2022 for 1,298 strokes and 2,031 myocardial infarctions, the shape of the link between moderate-vigorous physical activity (MVPA) and each outcome depended on how the accelerometer data were processed. For stroke, hazard fell in a straight line only with the machine-learning metric; for myocardial infarction, two metrics gave a curved decline and activity counts a straight one. The abstract gives no hazard ratios, so it shows that methods disagree, not which one is right, and the findings are observational associations.

Preventive Medicine

Explications approfondiesLire l’étude →
·Validation : étude/revue

Smartwatch data as forensic evidence: heart rate is best validated, the rest uneven

A systematic review and meta-analysis of studies on smartwatches from four major brands, framed around digital forensics, found that heart rate was both the most studied and the most accurate measure. Step count, distance, energy expenditure, activity classification and sleep were less consistently validated, and results varied by brand, protocol and reporting. The abstract gives no pooled numbers, and most studies were run in healthy people in laboratories, so it cannot say how a particular watch performs for a particular person in daily life.

Forensic Science International

Explications approfondiesLire l’étude →
·Synthèse de revues

Activity trackers: about 1,800 more steps a day, but small effects on other outcomes

An umbrella review of 39 systematic reviews and meta-analyses, covering 163,992 participants, found that activity trackers were associated with more physical activity (SMD 0.3–0.6), equating to about 1,800 extra steps and 40 minutes more walking per day, and with a bodyweight reduction of about 1 kg. Effects on blood pressure, cholesterol, glycosylated haemoglobin, quality of life and pain were typically small and often non-significant. The abstract does not say what else came with the trackers in these programs or how much the reviews overlap, so the gains cannot be credited to the device alone.

The Lancet Digital Health

Explications approfondiesLire l’étude →
·Validation : étude/revue

Seven sleep trackers: good at spotting sleep, weak on wake and sleep stages

In a sleep laboratory, 34 healthy young adults wore a subset of seven consumer sleep trackers for three nights. Against polysomnography every device detected sleep very well (sensitivity 0.93 or higher) but caught wake poorly (specificity 0.18–0.54), and five of the seven matched or beat research actigraphy (specificity 0.39). Sleep-stage estimates were inconsistent, and the participants were healthy adults aged 18 to 35 in a fixed 8-hour bed window, with each device tested in only 11 to 20 of them, so the results say little about people with sleep problems.

Sleep

Explications approfondiesLire l’étude →
Capteurs et mesures →