Fitbit Charge HR in children aged 9-11: decent at spotting sleep, weak at spotting wake

Collectif éditorial MoveVitals · Study published · Reading updated

Original paper:Performance of a commercial multi-sensor wearable (Fitbit Charge HR) in measuring physical activity and sleep in healthy children. · PloS one · 2020 · Article original ↗

À retenir

In 59 healthy children aged 9-11, the Fitbit Charge HR underestimated steps (~11.8 per minute) and heart rate (~3.58 bpm) and identified sleep well (95.8% sensitivity) but wake poorly (56.3% specificity). Sleep was checked in only 26 children, so the sleep accuracy figures rest on a small group.

Study design

Article de recherche

Reading basis

Published abstract

Reading focus

Design & applicability

Cette explication éditoriale existe en anglais, chinois simplifié et chinois traditionnel. Cette interface affiche la lecture en anglais.

Question de recherche

Consumer activity trackers are increasingly worn by children, but most accuracy testing has been done in adults. The authors tested how closely the Fitbit Charge HR matches research-grade measures of physical activity and polysomnography (PSG, the lab standard for sleep) in children.

Population et méthode

Validation study. 59 healthy boys and girls aged 9-11 wore a Fitbit Charge HR during 14 standardized laboratory and field activities (sitting, stationary cycling, treadmill walking or jogging, stair walking, outdoor walking and agility drills), compared with research-grade measures. Sleep was compared with at-home unattended overnight PSG in 26 children. Agreement was assessed with the Bland-Altman method and with epoch-by-epoch (minute-by-minute) analyses.

Résultats

The authors’ reported results. Read each estimate with its population and uncertainty.

  1. 1
    Compared with research-grade measures, the device underestimated steps (~11.8 steps per minute), heart rate (~3.58 bpm) and metabolic equivalents (~0.55 METs per minute) and overestimated energy expenditure (~0.34 kcal per minute), all at p< 0.05.
  2. 2
    For activity intensity, overall accuracy was 84.8% in separating moderate-to-vigorous from sedentary and light activity (sensitivity 85.4% for MVPA; specificity 83.1% for sedentary and light activity).
  3. 3
    For sleep, mean bias was 14 min for total sleep time, 9 min for wake after sleep onset and 1.06 bpm for heart rate during sleep.
  4. 4
    Sleep detection was sensitive (95.8%) but wake detection was not (56.3% specificity), so the device labels some awake time as sleep. Heart rate was more accurate during sleep than during exercise.

Limites et incertitude

  1. 1
    Only 26 of the 59 children had a sleep recording, and all were healthy, so results may not hold for children with sleep problems or illness.
  2. 2
    Sleep was measured for one at-home night, and activities were fixed protocol tasks rather than free daily life.
  3. 3
    The abstract reports results for one device model (Fitbit Charge HR), which has since been superseded. This reading is based on the abstract only.

Mise en perspective

For a child's tracker, treat step counts and calorie numbers as rough estimates, since this device undercounted steps and overestimated energy expenditure. Total sleep time looked reasonably close, but nighttime awakenings are likely to be missed.

Vos données

If a child or teen wears a tracker, compare their numbers with themselves over weeks on the same device and same wrist rather than against other children or other brands. Treat steps, sleep time and heart rate as trends, not exact measurements.

Comprendre ce type de preuve

The index does not establish a precise design. Read the methods before making causal claims; check population, comparator, outcomes and uncertainty in the source.

Résumé structuré des auteurs English

Le résumé original en anglais est reproduit avec attribution sous la licence ouverte indiquée. Il s’agit d’une source, pas d’une interprétation MoveVitals. L’analyse préparée figure ci-dessus ; vérifiez les conclusions importantes dans la source.

Purpose

This study sought to assess the performance of the Fitbit Charge HR, a consumer-level multi-sensor activity tracker, to measure physical activity and sleep in children.

Methods

59 healthy boys and girls aged 9-11 years old wore a Fitbit Charge HR, and accuracy of physical activity measures were evaluated relative to research-grade measures taken during a combination of 14 standardized laboratory- and field-based assessments of sitting, stationary cycling, treadmill walking or jogging, stair walking, outdoor walking, and agility drills. Accuracy of sleep measures were evaluated relative to polysomnography (PSG) in 26 boys and girls during an at-home unattended PSG overnight recording. The primary analyses included assessment of the agreement (biases) between measures using the Bland-Altman method, and epoch-by-epoch (EBE) analyses on a minute-by-minute basis.

Results

Fitbit Charge HR underestimated steps (~11.8 steps per minute), heart rate (~3.58 bpm), and metabolic equivalents (~0.55 METs per minute) and overestimated energy expenditure (~0.34 kcal per minute) relative to research-grade measures (p< 0.05). The device showed an overall accuracy of 84.8% for classifying moderate and vigorous physical activity (MVPA) and sedentary and light physical activity (SLPA) (sensitivity MVPA: 85.4%; specificity SLPA: 83.1%). Mean estimates of bias for measuring total sleep time, wake after sleep onset, and heart rate during sleep were 14 min, 9 min, and 1.06 bpm, respectively, with 95.8% sensitivity in classifying sleep and 56.3% specificity in classifying wake epochs.

Conclusions

Fitbit Charge HR had adequate sensitivity in classifying moderate and vigorous intensity physical activity and sleep, but had limitations in detecting wake, and was more accurate in detecting heart rate during sleep than during exercise, in healthy children. Further research is needed to understand potential challenges and limitations of these consumer devices.

Sources et attribution

Performance of a commercial multi-sensor wearable (Fitbit Charge HR) in measuring physical activity and sleep in healthy children.

Godino JG, Wing D, de Zambotti M, Baker FC, Bagot K, Inkelis S, Pautz C, Higgins M, Nichols J, Brumback T, Chevance G, Colrain IM, Patrick K, Tapert SF.

PloS one · 2020-09-04

DOI: 10.1371/journal.pone.0237719 ↗PubMed · 32886714 ↗Europe PMC · Licence indiquée: cc by ↗

Abstract © the original authors, reproduced under the recorded open licence. Translations support reading; use the English record to check terminology and numerical results. Our methodological interpretation is separate from the authors’ conclusions.

Interprétation éditoriale MoveVitals · contenu éducatif · aucune évaluation clinique individuelle enregistrée

Sources vérifiées 2026-11-01

Guides pratiques

À lire ensemble

·Étude de cohorte

Activity–stroke and heart attack curves differ by accelerometer processing method

Among 90,237 UK Biobank adults free of cardiovascular disease at baseline, followed until December 2022 for 1,298 strokes and 2,031 myocardial infarctions, the shape of the link between moderate-vigorous physical activity (MVPA) and each outcome depended on how the accelerometer data were processed. For stroke, hazard fell in a straight line only with the machine-learning metric; for myocardial infarction, two metrics gave a curved decline and activity counts a straight one. The abstract gives no hazard ratios, so it shows that methods disagree, not which one is right, and the findings are observational associations.

Preventive Medicine

Explications approfondiesLire l’étude →
·Validation : étude/revue

Smartwatch data as forensic evidence: heart rate is best validated, the rest uneven

A systematic review and meta-analysis of studies on smartwatches from four major brands, framed around digital forensics, found that heart rate was both the most studied and the most accurate measure. Step count, distance, energy expenditure, activity classification and sleep were less consistently validated, and results varied by brand, protocol and reporting. The abstract gives no pooled numbers, and most studies were run in healthy people in laboratories, so it cannot say how a particular watch performs for a particular person in daily life.

Forensic Science International

Explications approfondiesLire l’étude →
·Synthèse de revues

Activity trackers: about 1,800 more steps a day, but small effects on other outcomes

An umbrella review of 39 systematic reviews and meta-analyses, covering 163,992 participants, found that activity trackers were associated with more physical activity (SMD 0.3–0.6), equating to about 1,800 extra steps and 40 minutes more walking per day, and with a bodyweight reduction of about 1 kg. Effects on blood pressure, cholesterol, glycosylated haemoglobin, quality of life and pain were typically small and often non-significant. The abstract does not say what else came with the trackers in these programs or how much the reviews overlap, so the gains cannot be credited to the device alone.

The Lancet Digital Health

Explications approfondiesLire l’étude →
·Validation : étude/revue

Seven sleep trackers: good at spotting sleep, weak on wake and sleep stages

In a sleep laboratory, 34 healthy young adults wore a subset of seven consumer sleep trackers for three nights. Against polysomnography every device detected sleep very well (sensitivity 0.93 or higher) but caught wake poorly (specificity 0.18–0.54), and five of the seven matched or beat research actigraphy (specificity 0.39). Sleep-stage estimates were inconsistent, and the participants were healthy adults aged 18 to 35 in a fixed 8-hour bed window, with each device tested in only 11 to 20 of them, so the results say little about people with sleep problems.

Sleep

Explications approfondiesLire l’étude →
Capteurs et mesures →