Smartphone HRV app: 1-minute recordings track SDNN and RMSSD, frequency measures need 3

Collectif éditorial MoveVitals · Study published · Reading updated

Original paper:A Novel Smartphone App for the Measurement of Ultra-Short-Term and Short-Term Heart Rate Variability: Validity and Reliability Study. · JMIR mHealth and uHealth · 2020 · Article original ↗

À retenir

In 60 healthy young adults, the Pulse Express Pro app gave SDNN, RMSSD and pNN50 values from short segments that stayed close to its own 5-minute standard and to ECG, with 1 minute enough for those three. The sample was healthy, seated and resting, so the result may not hold during movement, sleep or illness.

Study design

Validation : étude/revue

Reading basis

Published abstract

Reading focus

Reference & error

Cette explication éditoriale existe en anglais, chinois simplifié et chinois traditionnel. Cette interface affiche la lecture en anglais.

Question de recherche

Wearables and phone apps often give HRV from very short recordings, but nobody had checked how short is short enough. The authors tested how well shorter segments of a 5-minute recording match the full 5 minutes, and how closely the Pulse Express Pro (PEP) smartphone app agrees with an electrocardiogram (ECG).

Population et méthode

Validation and reliability study of 60 healthy adults (mean age 22.3 years, SD 3.0). Each person had a 5-minute seated resting HRV recording made at the same time by ECG and by the PEP app. Six indices were analysed (SDNN, RMSSD, pNN50, and normalized very-low-, low- and high-frequency power) across 9 time segments, from 0-1 minute up to the full 0-5 minutes. Each segment was compared with the 0-5 minute standard using standardized differences (ES), intraclass correlation coefficients (ICC) and Spearman correlation; ECG-versus-app agreement used Bland-Altman limits of agreement.

Résultats

The authors’ reported results. Read each estimate with its population and uncertainty.

  1. 1
    For SDNN, RMSSD and pNN50, every time segment gave a trivial difference from the 5-minute standard (ES <0.2) and very large to nearly perfect ICC and Spearman values (all >0.8), for both ECG and the app.
  2. 2
    The normalized frequency measures (nVLF, nLF, nHF) were less stable: ES ranged from trivial to small (0.01-0.40), and ICC and Spearman correlations from moderate to nearly perfect (0.39-0.96 and 0.40-0.96).
  3. 3
    Bland-Altman plots showed relatively narrow mean differences between ECG and the app for SDNN, RMSSD and pNN50 after consecutive 1-minute recordings. Acceptable limits of agreement for nLF and nHF appeared only after consecutive 3-minute recordings.
  4. 4
    The authors suggest a 1-minute recording for time-domain indices with the app and at least 3 minutes for nLF and nHF.

Limites et incertitude

  1. 1
    All 60 participants were healthy, young (mean age 22.3 years) and recorded sitting at rest, so results say little about older adults, people with heart conditions, exercise or overnight readings.
  2. 2
    Each person was measured in one 5-minute session, so day-to-day reliability was not tested; reliability here means agreement between shorter and longer segments of the same recording.
  3. 3
    The abstract names only one app and does not report agreement numbers for the ECG-app comparison beyond the qualitative Bland-Altman description.
  4. 4
    This reading is based on the abstract only.

Mise en perspective

If you use a phone app that reports RMSSD or SDNN, a short resting reading can reasonably reflect your longer-recording value, at least for this app in healthy young people. Frequency-based numbers such as LF and HF deserve longer recordings and more caution. Do not treat one app's numbers as interchangeable with another app or device.

Vos données

Take HRV readings seated and rested, at the same time of day, with the same app or sensor, and watch your trend over weeks rather than single values. RMSSD from a 1-minute morning reading is a sensible habit; do not compare your numbers against someone else's or across different devices.

Comprendre ce type de preuve

Agreement is specific to the device, firmware, reference, population and setting. Correlation is not agreement, and validating a metric is not proof of diagnostic or treatment benefit.

Résumé structuré des auteurs English

Le résumé original en anglais est reproduit avec attribution sous la licence ouverte indiquée. Il s’agit d’une source, pas d’une interprétation MoveVitals. L’analyse préparée figure ci-dessus ; vérifiez les conclusions importantes dans la source.

Background

Smartphone apps for heart rate variability (HRV) measurement have been extensively developed in the last decade. However, ultra-short-term HRV recordings taken by wearable devices have not been examined.

Objective

The aims of this study were the following: (1) to compare the validity and reliability of ultra-short-term and short-term HRV time-domain and frequency-domain variables in a novel smartphone app, Pulse Express Pro (PEP), and (2) to determine the agreement of HRV assessments between an electrocardiogram (ECG) and PEP.

Methods

In total, 60 healthy adults were recruited to participate in this study (mean age 22.3 years [SD 3.0 years], mean height 168.4 cm [SD 8.0 cm], mean body weight 64.2 kg [SD 11.5 kg]). A 5-minute resting HRV measurement was recorded via ECG and PEP in a sitting position. Standard deviation of normal R-R interval (SDNN), root mean square of successive R-R interval (RMSSD), proportion of NN50 divided by the total number of RR intervals (pNN50), normalized very-low-frequency power (nVLF), normalized low-frequency power (nLF), and normalized high-frequency power (nHF) were analyzed within 9 time segments of HRV recordings: 0-1 minute, 1-2 minutes, 2-3 minutes, 3-4 minutes, 4-5 minutes, 0-2 minutes, 0-3 minutes, 0-4 minutes, and 0-5 minutes (standard). Standardized differences (ES), intraclass correlation coefficients (ICC), and the Spearman product-moment correlation were used to compare the validity and reliability of each time segment to the standard measurement (0-5 minutes). Limits of agreement were assessed by using Bland-Altman plot analysis.

Results

Compared to standard measures in both ECG and PEP, pNN50, SDNN, and RMSSD variables showed trivial ES (<0.2) and very large to nearly perfect ICC and Spearman correlation coefficient values in all time segments (>0.8). The nVLF, nLF, and nHF demonstrated a variation of ES (from trivial to small effects, 0.01-0.40), ICC (from moderate to nearly perfect, 0.39-0.96), and Spearman correlation coefficient values (from moderate to nearly perfect, 0.40-0.96). Furthermore, the Bland-Altman plots showed relatively narrow values of mean difference between the ECG and PEP after consecutive 1-minute recordings for SDNN, RMSSD, and pNN50. Acceptable limits of agreement were found after consecutive 3-minute recordings for nLF and nHF.

Conclusions

Using the PEP app to facilitate a 1-minute ultra-short-term recording is suggested for time-domain HRV indices (SDNN, RMSSD, and pNN50) to interpret autonomic functions during stabilization. When using frequency-domain HRV indices (nLF and nHF) via the PEP app, a recording of at least 3 minutes is needed for accurate measurement.

Sources et attribution

A Novel Smartphone App for the Measurement of Ultra-Short-Term and Short-Term Heart Rate Variability: Validity and Reliability Study.

Chen YS, Lu WA, Pagaduan JC, Kuo CD.

JMIR mHealth and uHealth · 2020-07-31

DOI: 10.2196/18761 ↗PubMed · 32735219 ↗Europe PMC · Licence indiquée: cc by ↗

Abstract © the original authors, reproduced under the recorded open licence. Translations support reading; use the English record to check terminology and numerical results. Our methodological interpretation is separate from the authors’ conclusions.

Interprétation éditoriale MoveVitals · contenu éducatif · aucune évaluation clinique individuelle enregistrée

Sources vérifiées 2026-11-01

Guides pratiques

À lire ensemble

·Article de recherche

Short-term HRV was higher during slow breathing in 962 military men, injured or not

In 962 military men (median age 37.6 years), every short-term heart rate variability (HRV) measure was higher during slow breathing at six breaths a minute than during spontaneous breathing, injured or not; in fast resting breathers RMSSD rose from 15.57 to 21.89 ms. It was one session in a fixed order, so it shows an immediate effect, not lasting benefit.

European Journal of Applied Physiology

Explications approfondiesLire l’étude →
·Méta-analyse d’essais

Cold-water immersion: no strength gain, briefly weaker jumps, soreness relief uncertain

Across 22 randomised trials (375 participants, mostly men), one cold-water immersion after exercise did not change maximal isometric strength (g 0.08, 95% CI −0.11 to 0.26) and was followed by weaker jumping straight afterwards (g −0.68), gone by 24–48 hours. Lower soreness and creatine kinase looked favourable but weakened in sensitivity checks, and certainty was low to very low.

PeerJ

Explications approfondiesLire l’étude →
·Revue des preuves

Cold-water immersion after hard exercise: less soreness, better power, no strength gain

In a meta-analysis of 52 randomised trials, cold-water immersion after high-intensity exercise was followed 24 hours later by lower soreness (SMD −0.89), higher perceived recovery (0.66) and better muscular power (0.22), with no effect on strength. Participants could not be blinded, most were men, and many pooled results rest on few studies with high heterogeneity.

Sports Medicine

Explications approfondiesLire l’étude →
·Méthodes et interprétation

Acute:chronic workload ratio: no evidence it can reduce injury risk, authors argue

The authors argue there is no evidence for using the acute:chronic workload ratio (ACWR) in training-load management or to reduce injury risk: no study has properly estimated a causal effect, and the ratio is statistically inaccurate and ambiguous. This is a methodological critique, not a new data analysis, so it does not show that training load is unrelated to injury.

International Journal of Sports Physiology and Performance

Explications approfondiesLire l’étude →
Récupération →