Aller au contenu
Capteurs et mesuresRevue des preuves3 min read

Apps, trackers and prompts cut daily sitting (-41.28 minutes), but the effect faded

Collectif éditorial MoveVitals · Study published · Reading updated

Original paper:Using computer, mobile and wearable technology enhanced interventions to reduce sedentary behaviour: a systematic review and meta-analysis. · The international journal of behavioral nutrition and physical activity · 2017 · Article original ↗

À retenir

Pooling 15 randomised trials (1402 people), computer, mobile and wearable tools reduced sitting by a mean of -41.28 minutes per day (95% CI -60.99 to -21.58) in healthy adults. Almost all trials had high or unclear risk of bias, heterogeneity was high, and the benefit had almost vanished beyond 6 months.

Study design

Revue des preuves

Reading basis

Published abstract

Reading focus

Design & applicability

Cette explication éditoriale existe en anglais, chinois simplifié et chinois traditionnel. Cette interface affiche la lecture en anglais.

Question de recherche

Long sitting time is linked to poorer health, and apps, activity monitors, prompts, texts and websites are increasingly used to cut it. The authors asked whether such technology-based interventions reduce sedentary time in healthy adults, and which behaviour change techniques they use.

Population et méthode

Systematic review and meta-analysis of randomised controlled trials in healthy adults, found by searching five databases up to June 2016. Interventions had to use computer, mobile or wearable technology and measure sedentary time. Risk of bias was rated with the Cochrane tool, and interventions were coded with the Behaviour Change Technique Taxonomy (v1). Meta-analysis covered 15 of the 17 included trials.

Résultats

The authors’ reported results. Read each estimate with its population and uncertainty.

  1. 1
    Technology-based interventions reduced sitting by a mean of -41.28 min/day versus control at end of follow-up (95% CI -60.99 to -21.58; I2 = 77%; n = 1402).
  2. 2
    By follow-up length, the pooled reduction was -42.42 min/day at 3 months or less, -37.23 min/day at more than 3 to 6 months, and only -1.65 min/day beyond 6 months.
  3. 3
    Of 17 trials, 16 had a high or unclear risk of bias and 1 was low risk.
  4. 4
    A total of 46 behaviour change techniques (14 unique) were coded; the most common were prompts and cues, self-monitoring of behaviour, unspecified social support and goal setting.

Limites et incertitude

  1. 1
    Heterogeneity was high (I2 = 77%), so the average hides large differences between trials and tools.
  2. 2
    Only 1 of 17 trials was at low risk of bias, which weakens confidence in the size of the effect.
  3. 3
    The long-term result (-1.65 min/day) is close to zero, and the authors note short follow-ups, attrition and a lack of objective sitting measures.
  4. 4
    This reading is based on the abstract only, which does not say which devices or tools worked best.

Mise en perspective

Reminders and activity monitors can shave a meaningful amount of sitting time in the first few months, but this review suggests the effect fades if nothing else keeps it going. Pairing a prompt with a goal you set yourself is the combination the interventions used most. It does not show better health outcomes, only less sitting.

Vos données

Many wearables offer idle alerts, stand reminders and sedentary time. Use one device throughout, and compare weekly averages of sitting or inactive time against your own baseline. Because the benefit faded here, keep checking your trend monthly rather than assuming the habit has stuck.

Comprendre ce type de preuve

Check which designs were included, how searches and bias assessment were conducted, and the last search date. Publication date alone does not make the underlying evidence current.

Résumé structuré des auteurs English

Le résumé original en anglais est reproduit avec attribution sous la licence ouverte indiquée. Il s’agit d’une source, pas d’une interprétation MoveVitals. L’analyse préparée figure ci-dessus ; vérifiez les conclusions importantes dans la source.

Background

High levels of sedentary behaviour (SB) are associated with negative health consequences. Technology enhanced solutions such as mobile applications, activity monitors, prompting software, texts, emails and websites are being harnessed to reduce SB. The aim of this paper is to evaluate the effectiveness of such technology enhanced interventions aimed at reducing SB in healthy adults and to examine the behaviour change techniques (BCTs) used.

Methods

Five electronic databases were searched to identify randomised-controlled trials (RCTs), published up to June 2016. Interventions using computer, mobile or wearable technologies to facilitate a reduction in SB, using a measure of sedentary time as an outcome, were eligible for inclusion. Risk of bias was assessed using the Cochrane Collaboration's tool and interventions were coded using the BCT Taxonomy (v1).

Results

Meta-analysis of 15/17 RCTs suggested that computer, mobile and wearable technology tools resulted in a mean reduction of -41.28 min per day (min/day) of sitting time (95% CI -60.99, -21.58, I2 = 77%, n = 1402), in favour of the intervention group at end point follow-up. The pooled effects showed mean reductions at short (≤ 3 months), medium (>3 to 6 months), and long-term follow-up (>6 months) of -42.42 min/day, -37.23 min/day and -1.65 min/day, respectively. Overall, 16/17 studies were deemed as having a high or unclear risk of bias, and 1/17 was judged to be at a low risk of bias. A total of 46 BCTs (14 unique) were coded for the computer, mobile and wearable components of the interventions. The most frequently coded were "prompts and cues", "self-monitoring of behaviour", "social support (unspecified)" and "goal setting (behaviour)".

Conclusion

Interventions using computer, mobile and wearable technologies can be effective in reducing SB. Effectiveness appeared most prominent in the short-term and lessened over time. A range of BCTs have been implemented in these interventions. Future studies need to improve reporting of BCTs within interventions and address the methodological flaws identified within the review through the use of more rigorously controlled study designs with longer-term follow-ups, objective measures of SB and the incorporation of strategies to reduce attrition.

Trial registration

The review protocol was registered with PROSPERO: CRD42016038187.

Sources et attribution

Using computer, mobile and wearable technology enhanced interventions to reduce sedentary behaviour: a systematic review and meta-analysis.

Stephenson A, McDonough SM, Murphy MH, Nugent CD, Mair JL.

The international journal of behavioral nutrition and physical activity · 2017-08-11

DOI: 10.1186/s12966-017-0561-4 ↗PubMed · 28800736 ↗Europe PMC · Licence indiquée: cc by ↗

Abstract © the original authors, reproduced under the recorded open licence. Translations support reading; use the English record to check terminology and numerical results. Our methodological interpretation is separate from the authors’ conclusions.

Interprétation éditoriale MoveVitals · contenu éducatif · aucune évaluation clinique individuelle enregistrée

Sources vérifiées 2026-11-01

Guides pratiques

À lire ensemble

·Étude de cohorte

Activity–stroke and heart attack curves differ by accelerometer processing method

Among 90,237 UK Biobank adults free of cardiovascular disease at baseline, followed until December 2022 for 1,298 strokes and 2,031 myocardial infarctions, the shape of the link between moderate-vigorous physical activity (MVPA) and each outcome depended on how the accelerometer data were processed. For stroke, hazard fell in a straight line only with the machine-learning metric; for myocardial infarction, two metrics gave a curved decline and activity counts a straight one. The abstract gives no hazard ratios, so it shows that methods disagree, not which one is right, and the findings are observational associations.

Preventive Medicine

Explications approfondiesLire l’étude →
·Validation : étude/revue

Smartwatch data as forensic evidence: heart rate is best validated, the rest uneven

A systematic review and meta-analysis of studies on smartwatches from four major brands, framed around digital forensics, found that heart rate was both the most studied and the most accurate measure. Step count, distance, energy expenditure, activity classification and sleep were less consistently validated, and results varied by brand, protocol and reporting. The abstract gives no pooled numbers, and most studies were run in healthy people in laboratories, so it cannot say how a particular watch performs for a particular person in daily life.

Forensic Science International

Explications approfondiesLire l’étude →
·Synthèse de revues

Activity trackers: about 1,800 more steps a day, but small effects on other outcomes

An umbrella review of 39 systematic reviews and meta-analyses, covering 163,992 participants, found that activity trackers were associated with more physical activity (SMD 0.3–0.6), equating to about 1,800 extra steps and 40 minutes more walking per day, and with a bodyweight reduction of about 1 kg. Effects on blood pressure, cholesterol, glycosylated haemoglobin, quality of life and pain were typically small and often non-significant. The abstract does not say what else came with the trackers in these programs or how much the reviews overlap, so the gains cannot be credited to the device alone.

The Lancet Digital Health

Explications approfondiesLire l’étude →
·Validation : étude/revue

Seven sleep trackers: good at spotting sleep, weak on wake and sleep stages

In a sleep laboratory, 34 healthy young adults wore a subset of seven consumer sleep trackers for three nights. Against polysomnography every device detected sleep very well (sensitivity 0.93 or higher) but caught wake poorly (specificity 0.18–0.54), and five of the seven matched or beat research actigraphy (specificity 0.39). Sleep-stage estimates were inconsistent, and the participants were healthy adults aged 18 to 35 in a fixed 8-hour bed window, with each device tested in only 11 to 20 of them, so the results say little about people with sleep problems.

Sleep

Explications approfondiesLire l’étude →
Capteurs et mesures →