在160名跑者的主要分析中,鞋墊實時回饋未減少跑步損傷

MoveVitals 編輯部 · 研究發表 · 解讀更新

原文:The Effect of Wearable-Based Real-Time Feedback on Running Injuries and Running Performance: A Randomized Controlled Trial. · The American journal of sports medicine · 2024 · 論文原文 ↗

先看重點

在一項納入220名業餘跑者的隨機試驗中,意向性治療分析顯示,鞋墊實時回饋並未顯著改變損傷發生率(HR 1.11,P = .70)。由於160名納入分析者中有53人(33%)使用了錯誤設定,按實際接受處理分析中較低的損傷率(HR 0.53,P = .03)可靠性較差。

證據類型

隨機對照試驗

解讀依據

公開摘要

閱讀重點

對照與不確定性

研究在問什麼

跑步技術和速度被認為是跑步損傷的重要危險因素,穿戴式裝置可以實時指導兩者。作者檢驗了壓敏鞋墊的實時回饋能否減少損傷、提高跑步表現,對照為無回饋。

研究對象與方法

隨機對照試驗(荷蘭試驗註冊中心註冊),納入220名業餘跑者。兩組都拿到壓敏鞋墊,但只有介入組收到關於時空指標和相對速度的實時回饋,目的是降低估計負荷最高的關節或肢段的負擔。用Cox迴歸比較損傷率。次要結局包括損傷嚴重程度、多次損傷、自報個人最好成績、運動動機(BREQ-2)以及研究結束後繼續使用穿戴式裝置的意願。摘要未說明追蹤時間。

主要發現

以下為作者報告的結果。數值須連同族群和不確定性一起閱讀。

  1. 1
    220名隨機分組者中,160人(73%)納入主要分析。意向性治療分析顯示損傷率無顯著差異(HR 1.11,P = .70)。
  2. 2
    按實際接受處理分析顯示回饋組損傷率更低(HR 0.53,P = .03),首次損傷嚴重程度也更低(-0.43,P = .042)。符合方案分析無顯著差異,但方向有利於介入組(HR 0.67,P = .30)。
  3. 3
    多次損傷(HR 0.82,P = .40)、跑步表現(3.07%,P = .26)和運動動機均無顯著差異。
  4. 4
    完成研究的參與者中約60%有興趣繼續使用該穿戴式裝置。

限制與不確定性

  1. 1
    160名納入分析者中有53人(33%)使用了錯誤設定,抵消了介入效果,使受隨機化保護的分析結果為陰性。
  2. 2
    按實際接受處理分析破壞了隨機化,正確使用裝置者可能與未正確使用者本身不同。
  3. 3
    僅73%的隨機分組者進入主要分析,摘要也未給出損傷例數和追蹤時間。
  4. 4
    跑步表現以自報個人最好成績衡量。本解讀僅基於摘要。

日常健康啟示

從本試驗的主要結果看,並未證明鞋墊回饋能預防跑步損傷,正確使用者中較低的損傷率只能視為線索。若使用回饋型穿戴式裝置,設定正確顯然很重要。持續疼痛或受傷應由醫師或物理治療師評估。

如何連結自己的資料

跑步類穿戴式裝置會報告步頻、觸地時間、步幅指標和配速。請使用同一裝置和設定,依賴任何回饋之前先核對設定,並結合痠痛記錄觀察數週趨勢,而不是對單次跑步做出反應。

如何理解這類證據

隨機分組有助於因果推斷,仍須檢查分配、盲法、失去追蹤、追蹤時間和具體對照;標為隨機試驗不自動意味著高確定性。

作者的結構化摘要 English

以下英文摘要依所記錄的開放授權轉載,屬於作者原始材料,並非 MoveVitals 解讀。上方已提供研究解讀,分別說明作者結果與本站解釋;重要結論可直接查核原文。

Background

Running technique and running speed are considered important risk factors for running injuries. Real-time feedback on running technique and running speed by wearables may help reduce injury risk.

Purpose

To investigate whether real-time feedback on spatiotemporal metrics and relative speed by commercially available pressure-sensitive insoles would reduce running injuries and improve running performance compared with no real-time feedback.

Study design

Randomized controlled trial; Level of evidence, 1.

Methods

A total of 220 recreational runners were randomly assigned into the intervention and control groups. Both groups received pressure-sensitive insoles, but only the intervention group received real-time feedback on spatiotemporal metrics and relative speed. The feedback aimed to reduce loading on the joint/segment estimated to exhibit the highest load. Injury rates were compared between the groups using Cox regressions. Secondary outcomes compared included injury severity, the proportion of runners with multiple injuries, changes in self-reported personal best times and motivation (Behavioral Regulation in Exercise Questionnaire-2), and interest in continuing wearable use after study completion.

Results

A total of 160 participants (73%) were included in analyses of the primary outcome. Intention-to-treat analysis showed no significant difference in injury rate between the groups (Hazard ratio [HR], 1.11; P = .70). This was expected, as 53 of 160 (33%) participants ended up in the unassigned group because they used incorrect wearable settings, nullifying any interventional effects. As-treated analysis showed a significantly lower injury rate among participants receiving real-time feedback (HR, 0.53; P = .03). Similarly, the first-time injury severity was significantly lower (-0.43; P = .042). Per-protocol analysis showed no significant differences in injury rates, but the direction favored the intervention group (HR, 0.67; P = .30). There were no significant differences in the proportion of patients with multiple injuries (HR, 0.82; P = .40) or changes in running performance (3.07%; P = .26) and motivation. Also, ~60% of the participants who completed the study showed interest in continuing wearable use.

Conclusion

Real-time feedback on spatiotemporal metrics and relative speed provided by commercially available instrumented insoles may reduce the rate and severity of injuries in recreational runners. Feedback did not influence running performance and exercise motivation.

Registration

NL8472 (Dutch Trial Register).

來源與署名

The Effect of Wearable-Based Real-Time Feedback on Running Injuries and Running Performance: A Randomized Controlled Trial.

Van Hooren B, Plasqui G, Meijer K.

The American journal of sports medicine · 2024-01-29

DOI: 10.1177/03635465231222464 ↗PubMed · 38287728 ↗Europe PMC · 所記錄的開放授權: cc by ↗

摘要著作權歸原作者,依來源紀錄的開放授權轉載。中文譯文協助閱讀,英文摘要供查核術語及具體數值;本站的方法學解釋與作者結論分別呈現。

MoveVitals 編輯解讀 · 健康教育內容 · 未記錄個人臨床審閱

來源查核日期 2026-11-01

實用健康指南

放在一起讀

·世代研究

加速度計處理方法不同,身體活動與中風、心肌梗死的關聯曲線也不同

在英國生物銀行中,基線無心血管疾病的90237名成年人追蹤至2022年12月,共發生1298例中風和2031例心肌梗死;中高強度身體活動(MVPA)與這兩種結局的關聯曲線形狀,取決於加速度計資料的處理方法。就中風而言,只有機器學習法得到直線下降的風險;就心肌梗死而言,機器學習法和LFENMO法呈曲線下降,活動計數法呈直線下降。摘要沒有給出風險比,只能說明不同方法的結論不一致,不能說明哪種方法更正確,而且這些只是觀察性關聯。

Preventive Medicine

重點論文精講閱讀論文 →
·測量驗證研究/回顧

智慧手錶資料能當「證人」嗎:心率驗證得最充分,其餘證據參差

一項圍繞數字取證展開的系統評價和統合分析,梳理了四大主流品牌智慧手錶的驗證研究,發現心率是研究最多、也最準確的指標。步數、距離、能量消耗、活動分類和睡眠的驗證不夠一致,結果因品牌、方案和報告方式而異。摘要沒有給出彙總資料,且多數研究是在健康族群中、於實驗室內完成的,所以無法說明某一塊手錶對某個人在日常生活中的表現。

Forensic Science International

重點論文精講閱讀論文 →
·回顧的回顧

活動追蹤器:每天多走約1800步,對其他健康指標影響較小

這項傘形綜述彙總了39篇系統評價和統合分析,涉及163992名參與者;結果顯示使用活動追蹤器與身體活動增加相關(標準化均數差SMD為0.3–0.6),相當於每天多走約1800步、多步行40分鐘,體重減輕約1公斤。對血壓、膽固醇、糖化血紅蛋白、生活質量和疼痛的影響通常很小,且多數不顯著。摘要沒有說明這些專案裡追蹤器還搭配了什麼,也沒有說明各評價之間重疊多少,因此不能把效果完全歸功於裝置本身。

The Lancet Digital Health

重點論文精講閱讀論文 →
·測量驗證研究/回顧

七款睡眠追蹤裝置:識別睡著很準,識別醒著和睡眠分期較差

在睡眠實驗室裡,34名健康的年輕成年人連續三晚佩戴七款消費級睡眠追蹤裝置中的若干款。與多導睡眠監測相比,所有裝置識別睡眠都很準(靈敏度均不低於0.93),但識別清醒較差(特異度0.18–0.54),七款中有五款與研究用活動記錄儀(特異度0.39)持平或更好;睡眠分期的估計結果不穩定。受試者是18至35歲的健康成年人,臥床時間固定為8小時,每款裝置只在其中11至20人身上測試,因此對有睡眠問題的人幾乎沒有參考價值。

Sleep

重點論文精講閱讀論文 →
穿戴裝置與測量科學 →