慢性腰痛的疼痛和活动量通常只在某一时间点凭回忆评估,容易产生回忆偏倚,也掩盖了日常波动。作者想知道,在家中实时记录时疼痛与活动是什么样子,患者自评的活动量与可穿戴运动传感器的记录又有多大差距。

研究了谁,如何研究

队列研究,纳入1007名符合美国国立卫生研究院标准的慢性腰痛成人,来自匹兹堡大学LB^(3)P机制研究中心,其中989人提交了数据。7天内,定制手机应用每天三次提示参与者评定当前疼痛强度(0~10分)、疼痛干扰(0~10分)和活动水平(很轻到剧烈),并报告入睡和起床时间。参与者在手腕和腰部佩戴ActiGraph GT9X,并在腰骶L5节段皮肤上贴定制传感器。每天佩戴至少10小时才计入,且至少需要4天有效数据。活动计数按Freedson成人切点分为久坐、轻度和中等到极剧烈强度。

主要发现

以下为作者报告的结果。数字须连同人群和不确定性一起阅读。

  1. 1
    实时疼痛评分偏低:疼痛强度中位数为1(四分位距3),疼痛干扰为3(四分位距3),54.0%的参与者强度中位数为0或1,而入组时平均疼痛强度为5.4(标准差2.1)。
  2. 2
    30%的参与者疼痛强度、40%的参与者疼痛干扰在傍晚达到高峰。多数人自评活动为中等(36%)或轻度(33%)。
  3. 3
    传感器结果不同:久坐时间占比腕部47.3%、腰部72.8%、背部传感器82.6%(586人)。每天步数中位数腕部9575步(884台设备)、腰部4114步(785台设备)、背部3695步。
  4. 4
    佩戴位置不同,同一群人的活动水平差别明显;自评活动量高于传感器推算值,腰部和背部的活动计数低于美国成人平均水平。

局限与不确定性

  1. 1
    摘要只描述了概况,没有无腰痛对照组,无法说明这些疼痛和活动水平对慢性腰痛是否特殊。
  2. 2
    活动分级使用的Freedson切点并非针对慢性腰痛人群制定;作者自己也指出,差异可能源于参与者高估活动量,也可能是切点不适用。
  3. 3
    仅观察7天,背部传感器只有586人的数据,且传感器位置会改变数值,不同设备的结果不能互换。
  4. 4
    以上仅依据摘要,未报告校正分析或长期随访。

对日常健康的启示

门诊时的一次疼痛评分可能漏掉一天中的疼痛波动,自评的“中等活动”也可能比传感器记录偏高。不要把这些中位数当作自己腰痛的标准或目标;若疼痛影响了日常生活,应与医生沟通。

如何联系自己的数据

如果记录步数或活动分钟数,请固定佩戴部位,因为本研究中手腕、腰部和背部得到的数值差别很大。比较自己不同周的数据,也可以在固定时间点记下疼痛,看看傍晚是否更明显。

如何理解这类证据

暴露先于随访结局,仍可能存在混杂和反向因果。危险比不是个人绝对风险,也不等于已证明的干预效果。

作者的结构化摘要 English

以下英文摘要按记录的开放许可转载,属于作者原始材料,不是 MoveVitals 的解读。上方已提供研究解读,分别说明作者结果与本站解释;重要结论可直接核对原文。

Background

Chronic low back pain (cLBP) is a prevalent and debilitating condition. Gaining insight into the daily experiences of those with cLBP is crucial for developing effective management. Pain and activity are typically assessed at a single time point and often rely on retrospective self-reports, which can be prone to recall bias and may not reflect the day-to-day variability of these experiences. As a part of the University of Pittsburgh LB^(3)P Mechanistic Research Center, this study used ecological momentary assessment (EMA) and wearable devices to collect real-time data in a large cohort of adults with cLBP. The primary aims were to collect and characterize pain and activity profiles of individuals with cLBP.

Methods

This study enrolled 1007 adults with cLBP who met the National Institutes of Health defined criteria. Over 7 days, participants were assessed in their own environment. EMA was gathered in real-time via a custom mobile app, prompting participants three times daily to provide their perceptions of current pain intensity (0-10), pain interference (0-10), and activity level (very light to vigorous). Time of falling asleep and waking was also reported. Participants wore ActiGraph GT9X devices on their wrist and waist. A custom back sensor was also adhered to the skin over the lumbar (L5) segment. Activity counts, wear time, and step counts were calculated, utilizing algorithms provided by ActiGraph. Sensor data were filtered to include at least 4 days of 10 or more hours each. Activity counts were categorized into sedentary, light, and moderate-to-very-vigorous based on Freedson Adult cutpoints.

Results

Out of 1007 participants, 989 submitted EMA data (58.8 ± 16.5 years old; 40% male and 60% female; mean pain intensity at enrollment of 5.4 (SD 2.1) and a median of 5 (interquartile range [IQR] 3) on a 0-10 scale; mean PROMIS Pain Interference T -score at enrollment of 60.5 (SD 7.5) and a median of 61.2 (IQR 9.6)). The median reported pain intensity level from the EMA was 1 (IQR = 3), while pain interference was 3 (IQR = 3). More than half of the participants reported a median pain intensity of either 0 or 1 (54.0%) and a median pain interference between 0 and 3 (57.4%). Most participants self-reported their activity levels as moderate (36%) or light (33%). Based on pain ratings during each day, most participants had their pain intensity (30%) and pain interference (40%) peaking in the evening. ActiGraph data from 884 wrist-worn and 785 waist-worn devices were analyzed. Wrist data showed a median of 1 765 325 (IQR 796 995) activity counts/day and 9575 (IQR 4228) steps/day. Waist data showed 358 390 (IQR 223 758) activity counts/day and 4114 (IQR 3146) steps/day. The percentage of daily sedentary activity was 47.3% for wrist and 72.8% for waist. The back sensor data from 586 participants showed a median of 340 345 (IQR = 223 399) activity counts/day and a median of 3695 (IQR = 2743) steps/day. The percentage of time spent in daily sedentary activity was 82.6%. Both ActiGraph devices and the back sensor indicated that the majority of the time was spent in sedentary activity level, which is lower than the activity level reported in the EMA.

Conclusions

Despite having cLBP with self-reported moderate pain levels, participants generally reported periods of relatively low levels of pain intensity and interference in their EMA. In addition, their EMA-reported activity levels differed from the sensor data. Participants self-reported higher levels of activity compared to the activity levels calculated by the wearable sensors. This suggests that participants overestimated their activity levels on EMA, or that the activity level cut-points may need to be re-evaluated for the cLBP population. Additionally, sensors placed on different body locations showed varying activity and step counts. The activity counts calculated from the waist ActiGraph and the back sensor from this cohort were lower than the average activity counts in the US adult population. Further research is needed to better quantify these differences for people with cLBP to develop a more comprehensive understanding of the pain experience.

来源与署名

In-Field Ecological Momentary Assessment From Wearable Motion Sensors and Self-Report in a Chronic Low Back Pain Cohort.

Bell KM, Alfikri Z, Anderst W, Clark WW, Cook HA, Darwin J, Dicianno BE, Greco CM, Hoydick J, Jakicic JM, McKernan GP, Parmanto B, Patterson CG, Piva SR, Roos RE, Schneider MJ, Sundaram M, Vo NV, Zhou L, Sowa GA.

JOR spine · 2026-02-01

DOI: 10.1002/jsp2.70156 ↗PubMed · 41635465 ↗Europe PMC · 记录的开放许可: cc by ↗

摘要版权归原作者,依据来源记录的开放许可转载。中文译文辅助阅读,英文摘要用于核对术语与具体数值;本站的方法学解释与作者结论分别呈现。

MoveVitals 编辑解读 · 健康教育内容 · 未记录个人临床审阅

来源核验日期 2026-11-01

实用健康指南

放在一起读

·队列研究

加速度计处理方法不同,身体活动与卒中、心肌梗死的关联曲线也不同

在英国生物银行中,基线无心血管疾病的90237名成年人随访至2022年12月,共发生1298例卒中和2031例心肌梗死;中高强度身体活动(MVPA)与这两种结局的关联曲线形状,取决于加速度计数据的处理方法。就卒中而言,只有机器学习法得到直线下降的风险;就心肌梗死而言,机器学习法和LFENMO法呈曲线下降,活动计数法呈直线下降。摘要没有给出风险比,只能说明不同方法的结论不一致,不能说明哪种方法更正确,而且这些只是观察性关联。

Preventive Medicine

重点论文精讲阅读论文 →
·测量验证研究/综述

智能手表数据能当“证人”吗:心率验证得最充分,其余证据参差

一项围绕数字取证展开的系统评价和荟萃分析,梳理了四大主流品牌智能手表的验证研究,发现心率是研究最多、也最准确的指标。步数、距离、能量消耗、活动分类和睡眠的验证不够一致,结果因品牌、方案和报告方式而异。摘要没有给出汇总数据,且多数研究是在健康人群中、于实验室内完成的,所以无法说明某一块手表对某个人在日常生活中的表现。

Forensic Science International

重点论文精讲阅读论文 →
·综述的综述

活动追踪器:每天多走约1800步,对其他健康指标影响较小

这项伞形综述汇总了39篇系统评价和荟萃分析,涉及163992名参与者;结果显示使用活动追踪器与身体活动增加相关(标准化均数差SMD为0.3–0.6),相当于每天多走约1800步、多步行40分钟,体重减轻约1公斤。对血压、胆固醇、糖化血红蛋白、生活质量和疼痛的影响通常很小,且多数不显著。摘要没有说明这些项目里追踪器还搭配了什么,也没有说明各评价之间重叠多少,因此不能把效果完全归功于设备本身。

The Lancet Digital Health

重点论文精讲阅读论文 →
·测量验证研究/综述

七款睡眠追踪设备:识别睡着很准,识别醒着和睡眠分期较差

在睡眠实验室里,34名健康的年轻成年人连续三晚佩戴七款消费级睡眠追踪设备中的若干款。与多导睡眠监测相比,所有设备识别睡眠都很准(灵敏度均不低于0.93),但识别清醒较差(特异度0.18–0.54),七款中有五款与研究用活动记录仪(特异度0.39)持平或更好;睡眠分期的估计结果不稳定。受试者是18至35岁的健康成年人,卧床时间固定为8小时,每款设备只在其中11至20人身上测试,因此对有睡眠问题的人几乎没有参考价值。

Sleep

重点论文精讲阅读论文 →
可穿戴与测量科学 →