可穿戴与测量科学测量验证研究/综述3 分钟阅读

可穿戴心率监测:佩戴部位影响准确性,开合跳类剧烈运动误差最大

MoveVitals 编辑部 · 研究发表 · 解读更新

原文:Impact of Anatomical Placement on the Accuracy of Wearable Heart Rate Monitors During Rest and Various Exercise Intensities. · Sensors (Basel, Switzerland) · 2025 · 论文原文 ↗

先看重点

在28名健康青年中,光学心率设备静息时与胸带高度一致(CCC > 0.99),但波比跳时一致性明显下降(CCC < 0.50),3个相同的Whoop 4.0戴在不同部位表现也不同。样本小且为健康人群、运动方案较短,结果未必适用于日常佩戴。

证据类型

测量验证研究/综述

解读依据

公开摘要

阅读重点

参照与测量误差

研究在问什么

光电容积脉搏波(PPG)心率传感器可戴在手腕、前臂或上臂,但运动加剧后佩戴部位究竟有多大影响并不清楚。作者以胸带为参照,比较了多种臂戴设备在静息和不同强度运动中的表现,并用3个相同的Whoop设备单独检验“佩戴位置”本身的作用。

研究了谁,如何研究

验证研究,纳入28名健康成年人(男女各14名,年龄23.8 ± 1.1岁)。每人同时佩戴6台设备:Polar H10胸带(参照)、前臂的Polar Verity Sense、手腕的Garmin Forerunner,以及分别戴在左手腕、前臂和上臂的3个相同的Whoop 4.0。受试者依次完成静息、热身、高强度波比跳和分级跑步机运动(改良Bruce方案)。用平均绝对百分比误差(MAPE)、Bland-Altman分析、一致性相关系数(CCC)和Deming回归评估一致性。摘要未给出具体误差数值。

主要发现

以下为作者报告的结果。数字须连同人群和不确定性一起阅读。

  1. 1
    静息时准确性最高,随运动强度增加逐渐下降。静息时所有设备偏差很小、一致性高(CCC > 0.99),其中Verity Sense的MAPE最低。
  2. 2
    热身阶段,上臂Whoop和Verity Sense优于手腕设备和Garmin,而前臂Whoop出现比例偏差和系统偏差。
  3. 3
    波比跳时所有设备准确性都最低(CCC < 0.50),但上臂Whoop好于其他佩戴位置。
  4. 4
    改良Bruce跑步机方案中,Verity Sense和上臂Whoop与胸带一致性最好。同一型号的Whoop中,上臂优于前臂和手腕。

局限与不确定性

  1. 1
    仅28名平均年龄23.8岁的健康成年人,结果未必适用于老年人、心脏病患者,也未必适用于不同肤色或腕围的人。
  2. 2
    运动为实验室内的短时方案(静息、热身、波比跳、跑步机),不是日常训练或睡眠。
  3. 3
    只测试了少数几个品牌型号,且摘要没有给出具体误差数值,无法判断佩戴部位造成的差异相当于每分钟多少次心跳。
  4. 4
    本解读仅基于摘要。

对日常健康的启示

若想在剧烈或动作多变的训练中获得更好的光学心率,把设备戴得靠近上臂、贴紧皮肤可能有帮助,但间歇训练或全身运动时胸带仍是更可靠的参照。不要想当然认为自己的设备也有同样表现,这只是一个小规模的年轻样本。

如何联系自己的数据

手腕或手臂传感器的静息心率和稳定强度下的心率总体可靠,按天看趋势是有意义的。做波比跳这类间歇训练时,读数只能当作近似值;若数值很重要,可在自己的训练中用同一设备、同一佩戴位置与胸带对照。

如何理解这类证据

一致性取决于设备、固件、参照、人群和场景。相关性不等于一致性;验证某个指标不等于已证明诊断或治疗获益。

作者的结构化摘要 English

以下英文摘要按记录的开放许可转载,属于作者原始材料,不是 MoveVitals 的解读。上方已提供研究解读,分别说明作者结果与本站解释;重要结论可直接核对原文。

Purpose

This study evaluated the accuracy of arm-based photoplethysmography (PPG) wearable heart rate (HR) monitors in comparison to a validated chest strap reference across various activity levels.

Methods

Twenty-eight healthy adults (14 males, 14 females; aged 23.8 ± 1.1 years) wore six HR monitors: Polar H10 chest strap, Polar Verity Sense on the forearm, Garmin Forerunner on the wrist, and three identical Whoop 4.0 devices placed on the left wrist, forearm, and upper arm. Participants completed rest, warm-up, high-intensity burpees, and graded treadmill exercise. HR data were analyzed using mean absolute percentage error (MAPE), Bland-Altman analysis, concordance correlation coefficient (CCC), and Deming regression.

Results

Accuracy was highest at rest and gradually decreased as movement intensity increased. During rest, all devices showed minimal bias and high agreement (CCC > 0.99), with Verity Sense recording the lowest MAPE. In warm-up, Whoop-upper arm and Verity Sense outperformed wrist and Garmin positions, while the Whoop-forearm showed proportional and systematic bias. Burpees resulted in the lowest accuracy across devices (CCC < 0.50), but Whoop-upper arm performed better than other placements. During the Modified Bruce protocol, Verity Sense and Whoop-upper arm had the strongest agreement with the chest strap. Placement of identical Whoop units affected accuracy, with the upper arm outperforming forearm and wrist positions.

Conclusions

PPG wearables provided accurate HR monitoring at rest, during warm-up, and during steady-state graded exercise, particularly when positioned proximally (forearm or upper arm). Accuracy declined during short, high-intensity, full-body activities due to motion artifacts. Both the forearm-mounted Verity Sense and the upper-arm Whoop demonstrated the closest agreement with the chest-strap reference. The intra-device comparison of identical Whoop units confirmed that anatomical placement alone significantly affects accuracy.

来源与署名

Impact of Anatomical Placement on the Accuracy of Wearable Heart Rate Monitors During Rest and Various Exercise Intensities.

Moghaddam M, Collins JP, Gardner CE, Rabel MC.

Sensors (Basel, Switzerland) · 2025-12-26

DOI: 10.3390/s26010176 ↗PubMed · 41516615 ↗Europe PMC · 记录的开放许可: cc by ↗

摘要版权归原作者,依据来源记录的开放许可转载。中文译文辅助阅读,英文摘要用于核对术语与具体数值;本站的方法学解释与作者结论分别呈现。

MoveVitals 编辑解读 · 健康教育内容 · 未记录个人临床审阅

来源核验日期 2026-11-01

实用健康指南

放在一起读

·队列研究

加速度计处理方法不同,身体活动与卒中、心肌梗死的关联曲线也不同

在英国生物银行中,基线无心血管疾病的90237名成年人随访至2022年12月,共发生1298例卒中和2031例心肌梗死;中高强度身体活动(MVPA)与这两种结局的关联曲线形状,取决于加速度计数据的处理方法。就卒中而言,只有机器学习法得到直线下降的风险;就心肌梗死而言,机器学习法和LFENMO法呈曲线下降,活动计数法呈直线下降。摘要没有给出风险比,只能说明不同方法的结论不一致,不能说明哪种方法更正确,而且这些只是观察性关联。

Preventive Medicine

重点论文精讲阅读论文 →
·测量验证研究/综述

智能手表数据能当“证人”吗:心率验证得最充分,其余证据参差

一项围绕数字取证展开的系统评价和荟萃分析,梳理了四大主流品牌智能手表的验证研究,发现心率是研究最多、也最准确的指标。步数、距离、能量消耗、活动分类和睡眠的验证不够一致,结果因品牌、方案和报告方式而异。摘要没有给出汇总数据,且多数研究是在健康人群中、于实验室内完成的,所以无法说明某一块手表对某个人在日常生活中的表现。

Forensic Science International

重点论文精讲阅读论文 →
·综述的综述

活动追踪器:每天多走约1800步,对其他健康指标影响较小

这项伞形综述汇总了39篇系统评价和荟萃分析,涉及163992名参与者;结果显示使用活动追踪器与身体活动增加相关(标准化均数差SMD为0.3–0.6),相当于每天多走约1800步、多步行40分钟,体重减轻约1公斤。对血压、胆固醇、糖化血红蛋白、生活质量和疼痛的影响通常很小,且多数不显著。摘要没有说明这些项目里追踪器还搭配了什么,也没有说明各评价之间重叠多少,因此不能把效果完全归功于设备本身。

The Lancet Digital Health

重点论文精讲阅读论文 →
·测量验证研究/综述

七款睡眠追踪设备:识别睡着很准,识别醒着和睡眠分期较差

在睡眠实验室里,34名健康的年轻成年人连续三晚佩戴七款消费级睡眠追踪设备中的若干款。与多导睡眠监测相比,所有设备识别睡眠都很准(灵敏度均不低于0.93),但识别清醒较差(特异度0.18–0.54),七款中有五款与研究用活动记录仪(特异度0.39)持平或更好;睡眠分期的估计结果不稳定。受试者是18至35岁的健康成年人,卧床时间固定为8小时,每款设备只在其中11至20人身上测试,因此对有睡眠问题的人几乎没有参考价值。

Sleep

重点论文精讲阅读论文 →
可穿戴与测量科学 →