跳到正文
可穿戴与测量科学随机对照试验4 分钟阅读

冠心病患者的远程心脏康复:Fitbit提升了运动能力,在线指导增加了活动量

MoveVitals 编辑部 · 研究发表 · 解读更新

原文:Wearable Devices in Remote Cardiac Rehabilitation With and Without Weekly Online Coaching for Patients With Coronary Artery Disease: Randomized Controlled Trial. · JMIR mHealth and uHealth · 2025 · 论文原文 ↗

先看重点

在这项纳入50名患者的远程心脏康复预试验中,使用Fitbit后,有在线指导组(+1.6 mL/kg/min,P<.001)和仅用可穿戴设备组(+0.6 mL/kg/min,P=.008)的峰值摄氧量较基线均有升高,两组间无差异(P=.65)。试验规模小、单中心且为开放标签,不能说明在线指导会提高体能。

证据类型

随机对照试验

解读依据

公开摘要

阅读重点

对照与不确定性

研究在问什么

心脏康复有助于预防心血管疾病,但许多患者难以参加相关项目。作者检验了基于可穿戴设备和实时监测的远程方案能否改善冠心病(CAD)患者的运动能力,以及再加上每周在线指导(OLC)能否进一步改善效果。

研究了谁,如何研究

这是一项随机、开放标签、单中心的预试验(III期),纳入50名冠心病患者。基线心肺运动试验(CPET)后,所有患者都获得基于CPET的居家运动方案、一台Fitbit Sense和一套实时监测系统(Recoval)。患者被随机分为可穿戴设备加在线指导组(n=25)和仅可穿戴设备对照组(CON,n=25)。主要结局是12周时峰值摄氧量(peak VO2)和无氧阈VO2的变化;次要结局包括其他CPET指标、日常活动、焦虑和健康相关生活质量。

主要发现

以下为作者报告的结果。数字须连同人群和不确定性一起阅读。

  1. 1
    两组12周时的峰值摄氧量均较基线升高:有在线指导组+1.6 mL/kg/min(P<.001),对照组+0.6 mL/kg/min(P=.008);组间差异无统计学意义(P=.65)。
  2. 2
    无氧阈VO2在两组也均升高:有在线指导组+1.0 mL/kg/min(P=.001),对照组+1.3 mL/kg/min(P=.002),组间无差异(P=.90)。
  3. 3
    在干预后半段,在线指导组的每日距离和高强度活动时间显著高于对照组(均P<.05)。
  4. 4
    两组的心理状态和健康相关生活质量评分无差异。未报告严重心脏不良事件,在线指导组有1名患者因下肢肌肉拉伤退出。

局限与不确定性

  1. 1
    每组仅25人,预试验的规模不足以检出两组之间较小的差异,组间无差异的结果可能是检验效能不足。
  2. 2
    没有不使用可穿戴设备或远程方案的对照组,因此两组体能的提升不能归因于技术本身。
  3. 3
    开放标签、单中心设计且随访仅12周,结果可能不适用于其他医院、人群或更长期的结局;作者呼吁在更多样的人群和更长时间中验证。
  4. 4
    在线指导组活动量的提升仅出现在后半段,来自设备记录的数据;以上解读仅基于摘要。

对日常健康的启示

对于无法前往中心的稳定冠心病患者,借助可穿戴设备和远程监测的居家方案在这项小型试验中看来可行,并与运动能力提升相关,但在线指导并未明显增加体能。远程康复应在心内科团队的安排下进行,由他们确定安全的运动强度。

如何联系自己的数据

该方案监测的是可穿戴设备记录的每日距离、活动分钟和运动中心率。请使用同一台设备和相近的路线,并关注数周的趋势。峰值摄氧量是在门诊测试中测得的,手表给出的VO2max估算值与它并不相同。

如何理解这类证据

随机分组有助于因果推断,仍须检查分配、盲法、失访、随访时间和具体对照;标为随机试验不自动意味着高确定性。

作者的结构化摘要 English

以下英文摘要按记录的开放许可转载,属于作者原始材料,不是 MoveVitals 的解读。上方已提供研究解读,分别说明作者结果与本站解释;重要结论可直接核对原文。

Background

Cardiac rehabilitation (CR) is effective in preventing cardiovascular diseases; however, participation in CR programs remains limited due to the associated challenges. The integration of wearable devices and real-time monitoring offers a potential solution to enhance adherence to remote CR programs and their outcomes.

Objective

This study aimed to evaluate the efficacy of a remote CR program using wearable devices and real-time monitoring with or without online coaching (OLC) in improving exercise capacity in patients with coronary artery disease (CAD).

Methods

We enrolled 50 patients with CAD in a remote CR program in this randomized, open-label, single-center pilot trial (phase III). After baseline cardiopulmonary exercise tests (CPETs), all patients were assigned a CPET-based home exercise program and were provided with a wearable device (Fitbit Sense; Fitbit, Inc) with a real-time monitoring system (Recoval; SapplyM, Inc). The patients were randomly assigned to an intervention group with OLC (n=25) or a control wearable device (CON; n=25) group. The primary outcomes were changes in peak oxygen consumption (peak VO2) and anaerobic threshold VO2 (oxygen consumption) at 12 weeks. The secondary outcomes were changes in CPET parameters, daily activity, anxiety levels, and health-related quality of life.

Results

Peak VO2 and anaerobic threshold VO2 increased significantly from baseline to 12 weeks in the OLC (+1.6 mL/kg/min, P<.001; +1.0 mL/kg/min, P=.001) and CON (+0.6 mL/kg/min, P=.008; +1.3 mL/kg/min, P=.002) groups with no significant between-group differences (P=.65 and P=.90). In the latter half of the intervention, the daily distance and highly active time in the OLC group were significantly increased compared with those in the CON group (all P<.05). Mental status and health-related quality of life scores showed no significant differences between the groups. No major adverse cardiac events were reported. One patient in the OLC group dropped out due to lower limb muscle strain.

Conclusions

Remote CR using wearable devices and a real-time monitoring system significantly improved exercise capacity in patients with CAD over a 12-week intervention program. The addition of regular OLC to the intervention program further enhanced the physical activity levels, particularly in high-intensity activities. Future studies are warranted to validate these findings in more diverse populations and over longer intervention periods to optimize the benefits and safety of remote CR programs.

来源与署名

Wearable Devices in Remote Cardiac Rehabilitation With and Without Weekly Online Coaching for Patients With Coronary Artery Disease: Randomized Controlled Trial.

Nishio R, Dohi T, Yokoyama M, Nakade T, Takahashi N, Chikata Y, Endo H, Nishiyama H, Okai I, Iwata H, Okazaki S, Miyauchi K, Daida H, Minamino T.

JMIR mHealth and uHealth · 2025-05-12

DOI: 10.2196/63797 ↗PubMed · 40395066 ↗Europe PMC · 记录的开放许可: cc by ↗

摘要版权归原作者,依据来源记录的开放许可转载。中文译文辅助阅读,英文摘要用于核对术语与具体数值;本站的方法学解释与作者结论分别呈现。

MoveVitals 编辑解读 · 健康教育内容 · 未记录个人临床审阅

来源核验日期 2026-11-01

实用健康指南

放在一起读

·队列研究

加速度计处理方法不同,身体活动与卒中、心肌梗死的关联曲线也不同

在英国生物银行中,基线无心血管疾病的90237名成年人随访至2022年12月,共发生1298例卒中和2031例心肌梗死;中高强度身体活动(MVPA)与这两种结局的关联曲线形状,取决于加速度计数据的处理方法。就卒中而言,只有机器学习法得到直线下降的风险;就心肌梗死而言,机器学习法和LFENMO法呈曲线下降,活动计数法呈直线下降。摘要没有给出风险比,只能说明不同方法的结论不一致,不能说明哪种方法更正确,而且这些只是观察性关联。

Preventive Medicine

重点论文精讲阅读论文 →
·测量验证研究/综述

智能手表数据能当“证人”吗:心率验证得最充分,其余证据参差

一项围绕数字取证展开的系统评价和荟萃分析,梳理了四大主流品牌智能手表的验证研究,发现心率是研究最多、也最准确的指标。步数、距离、能量消耗、活动分类和睡眠的验证不够一致,结果因品牌、方案和报告方式而异。摘要没有给出汇总数据,且多数研究是在健康人群中、于实验室内完成的,所以无法说明某一块手表对某个人在日常生活中的表现。

Forensic Science International

重点论文精讲阅读论文 →
·综述的综述

活动追踪器:每天多走约1800步,对其他健康指标影响较小

这项伞形综述汇总了39篇系统评价和荟萃分析,涉及163992名参与者;结果显示使用活动追踪器与身体活动增加相关(标准化均数差SMD为0.3–0.6),相当于每天多走约1800步、多步行40分钟,体重减轻约1公斤。对血压、胆固醇、糖化血红蛋白、生活质量和疼痛的影响通常很小,且多数不显著。摘要没有说明这些项目里追踪器还搭配了什么,也没有说明各评价之间重叠多少,因此不能把效果完全归功于设备本身。

The Lancet Digital Health

重点论文精讲阅读论文 →
·测量验证研究/综述

七款睡眠追踪设备:识别睡着很准,识别醒着和睡眠分期较差

在睡眠实验室里,34名健康的年轻成年人连续三晚佩戴七款消费级睡眠追踪设备中的若干款。与多导睡眠监测相比,所有设备识别睡眠都很准(灵敏度均不低于0.93),但识别清醒较差(特异度0.18–0.54),七款中有五款与研究用活动记录仪(特异度0.39)持平或更好;睡眠分期的估计结果不稳定。受试者是18至35岁的健康成年人,卧床时间固定为8小时,每款设备只在其中11至20人身上测试,因此对有睡眠问题的人几乎没有参考价值。

Sleep

重点论文精讲阅读论文 →
可穿戴与测量科学 →