可穿戴与测量科学证据综述3 分钟阅读

心脏康复维持期用可穿戴设备加运动指导,心肺适能提高更多(平均差1.65 mL/kg/min)

MoveVitals 编辑部 · 研究发表 · 解读更新

原文:Impact of wearable physical activity monitoring devices with exercise prescription or advice in the maintenance phase of cardiac rehabilitation: systematic review and meta-analysis. · BMC sports science, medicine & rehabilitation · 2019 · 论文原文 ↗

先看重点

在9项随机试验共1,352名参与者中,心脏病患者使用可穿戴监测设备并获得运动建议后,心肺适能比对照组平均多提高1.65 mL/kg/min(95%置信区间0.64-2.66)。步数的合并结果起初并不显著,要经敏感性分析才显著,而且纳入的试验数量少、差异大。

证据类型

证据综述

解读依据

公开摘要

阅读重点

方法与适用范围

研究在问什么

正规心脏康复结束后,心脏病患者需要终身保持活动。可穿戴活动监测设备被认为有帮助,但此前没有针对心脏病人群的综述。作者想知道,在维持期,可穿戴设备联合运动处方或建议能否改善心肺适能、日常活动量和久坐时间。

研究了谁,如何研究

对心脏病人群的随机对照试验做系统综述,检索相关数据库至2019年1月,进行叙述性综合、荟萃分析和定性分析(PROSPERO注册号CRD42019106591)。共纳入9项研究、1,352名参与者。结局包括心肺适能(CRF)、六分钟步行距离、步数、活动强度和久坐时间,同时汇总退出原因、不良事件和心理影响。

主要发现

以下为作者报告的结果。数字须连同人群和不确定性一起阅读。

  1. 1
    可穿戴设备加运动建议使心肺适能提高更多:平均差值1.65 mL/kg/min(95%置信区间0.64-2.66,p = 0.001,I2 = 0%)。六分钟步行距离在两组间无显著差异。
  2. 2
    70%的研究中步数更高,但合并效应不显著(标准化均数差0.45,95%置信区间-0.17至1.07,p = 0.15,I2 = 81%);敏感性分析后效应显著(标准化均数差0.78,95%置信区间0.54-1.02,p < 0.001,I2 = 0%)。
  3. 3
    报告活动强度的4项研究中有3项发现中等强度及中高强度活动时间增加;久坐时间无组间差异。
  4. 4
    6项研究中有3项报告了心理方面的益处。没有报告与身体活动相关的心脏不良事件;62%的非心脏不良事件主要是肌肉骨骼损伤。
  5. 5
    退出原因包括身体状况、缺乏动力、失去兴趣和技术问题。

局限与不确定性

  1. 1
    仅纳入9项研究,且多个结局只有少数研究报告,因此活动强度和心理方面的结论样本很小。
  2. 2
    步数结果的异质性很大(I2 = 81%),显著结果来自剔除部分研究的敏感性分析,属于事后选择。
  3. 3
    设备总是与运动处方或建议同时使用,无法把设备本身的作用与运动建议区分开。
  4. 4
    本解读仅基于摘要。

对日常健康的启示

对已完成心脏康复的人来说,这些试验提示可穿戴设备加运动指导与更好的实测心肺适能相关,且没有报告与活动相关的心脏不良事件。但摘要并未表明仅靠设备就足够。心脏病患者的运动计划和强度上限,应与心脏科团队商定。

如何联系自己的数据

可穿戴设备上的每日步数和活动分钟,正是这些试验所追踪的数据,许多手表还能估算最大摄氧量。请用同一设备比较不同周,持续的步数或估算体能趋势比单日数值更有参考价值。

如何理解这类证据

先看纳入了哪些设计、检索与偏倚评估如何完成,以及检索截止日期;发表新不代表底层证据都是最新的。

作者的结构化摘要 English

以下英文摘要按记录的开放许可转载,属于作者原始材料,不是 MoveVitals 的解读。上方已提供研究解读,分别说明作者结果与本站解释;重要结论可直接核对原文。

Background

Physical activity (PA) is a component of cardiac rehabilitation (CR). However, life-long engagement in PA is required to maintain benefits gained. Wearable PA monitoring devices (WPAM) are thought to increase PA. There appear to be no reviews which investigate the effect of WPAM in cardiac populations. We firstly aimed to systematically review randomised controlled trials within the cardiac population that investigated the effect WPAM had through the maintenance phase of CR. We specifically examined the effect on cardiorespiratory fitness (CRF), amount and intensity of daily PA, and sedentary time. Secondly, we aimed to collate outcome measures reported, reasons for drop out, adverse events, and psychological impact from utilising a WPAM.

Methods

A systematic search (up to January 2019) of relevant databases was completed, followed by a narrative synthesis, meta-analysis and qualitative analysis.

Results

Nine studies involving 1,352 participants were included. CRF was improved to a greater extent in participants using WPAM with exercise prescription or advice compared with controls (MD 1.65 mL/kg/min;95% confidence interval [CI; 0.64-2.66]; p = 0.001; I^(2) = 0%). There was no significant between group difference in six-minute walk test distance. In 70% of studies, step count was greater in participants using a WPAM with exercise prescription or advice, however the overall effect was not significant (SMD 0.45;95% [CI; - 0.17-1.07] p = 0.15; I^(2) = 81%). A sensitivity analysis resulted in significantly greater step counts in participants using a WPAM with exercise prescription or advice and reduced the heterogeneity from 81 to 0% (SMD 0.78;95% [CI;0.54-1.02]; p < 0.001; I^(2) = 0%). Three out of four studies reporting on intensity, found significantly increased time spent in moderate and moderate-vigorous intensity PA. No difference between groups was found for sedentary time. Three of six studies reported improved psychological benefits.No cardiac adverse events related to physical activity were reported and 62% of non-cardiac adverse events were primarily musculoskeletal injuries. Reasons for dropping out included medical conditions, lack of motivation, loss of interest, and technical difficulties.

Conclusions

Our meta-analysis showed WPAM with exercise prescription or advice are superior to no device in improving CRF in the maintenance phase of CR and no cardiac adverse events were reported with WPAM use. Our qualitative analysis showed evidence in favour of WPAM with exercise prescription or advice for both CRF and step count. WPAM with exercise prescription or advice did not change sedentary time. Psychological health and exercise intensity may potentially be enhanced by WPAM with exercise prescription or advice, however further research would strengthen this conclusion.

Trial registration

PROSPERO Registration Number: CRD42019106591.

来源与署名

Impact of wearable physical activity monitoring devices with exercise prescription or advice in the maintenance phase of cardiac rehabilitation: systematic review and meta-analysis.

Hannan AL, Harders MP, Hing W, Climstein M, Coombes JS, Furness J.

BMC sports science, medicine & rehabilitation · 2019-07-30

DOI: 10.1186/s13102-019-0126-8 ↗PubMed · 31384474 ↗Europe PMC · 记录的开放许可: cc by ↗

摘要版权归原作者,依据来源记录的开放许可转载。中文译文辅助阅读,英文摘要用于核对术语与具体数值;本站的方法学解释与作者结论分别呈现。

MoveVitals 编辑解读 · 健康教育内容 · 未记录个人临床审阅

来源核验日期 2026-11-01

实用健康指南

放在一起读

·队列研究

加速度计处理方法不同,身体活动与卒中、心肌梗死的关联曲线也不同

在英国生物银行中,基线无心血管疾病的90237名成年人随访至2022年12月,共发生1298例卒中和2031例心肌梗死;中高强度身体活动(MVPA)与这两种结局的关联曲线形状,取决于加速度计数据的处理方法。就卒中而言,只有机器学习法得到直线下降的风险;就心肌梗死而言,机器学习法和LFENMO法呈曲线下降,活动计数法呈直线下降。摘要没有给出风险比,只能说明不同方法的结论不一致,不能说明哪种方法更正确,而且这些只是观察性关联。

Preventive Medicine

重点论文精讲阅读论文 →
·测量验证研究/综述

智能手表数据能当“证人”吗:心率验证得最充分,其余证据参差

一项围绕数字取证展开的系统评价和荟萃分析,梳理了四大主流品牌智能手表的验证研究,发现心率是研究最多、也最准确的指标。步数、距离、能量消耗、活动分类和睡眠的验证不够一致,结果因品牌、方案和报告方式而异。摘要没有给出汇总数据,且多数研究是在健康人群中、于实验室内完成的,所以无法说明某一块手表对某个人在日常生活中的表现。

Forensic Science International

重点论文精讲阅读论文 →
·综述的综述

活动追踪器:每天多走约1800步,对其他健康指标影响较小

这项伞形综述汇总了39篇系统评价和荟萃分析,涉及163992名参与者;结果显示使用活动追踪器与身体活动增加相关(标准化均数差SMD为0.3–0.6),相当于每天多走约1800步、多步行40分钟,体重减轻约1公斤。对血压、胆固醇、糖化血红蛋白、生活质量和疼痛的影响通常很小,且多数不显著。摘要没有说明这些项目里追踪器还搭配了什么,也没有说明各评价之间重叠多少,因此不能把效果完全归功于设备本身。

The Lancet Digital Health

重点论文精讲阅读论文 →
·测量验证研究/综述

七款睡眠追踪设备:识别睡着很准,识别醒着和睡眠分期较差

在睡眠实验室里,34名健康的年轻成年人连续三晚佩戴七款消费级睡眠追踪设备中的若干款。与多导睡眠监测相比,所有设备识别睡眠都很准(灵敏度均不低于0.93),但识别清醒较差(特异度0.18–0.54),七款中有五款与研究用活动记录仪(特异度0.39)持平或更好;睡眠分期的估计结果不稳定。受试者是18至35岁的健康成年人,卧床时间固定为8小时,每款设备只在其中11至20人身上测试,因此对有睡眠问题的人几乎没有参考价值。

Sleep

重点论文精讲阅读论文 →