跳到正文
可穿戴与测量科学测量验证研究/综述3 分钟阅读

两款Fitbit对老年人步数记录稳定,但普遍偏低

MoveVitals 编辑部 · 研究发表 · 解读更新

原文:Reliability and validity of two fitness tracker devices in the laboratory and home environment for older community-dwelling people. · BMC geriatrics · 2018 · 论文原文 ↗

先看重点

共31名老年人完成两次2分钟步行测试,Fitbit Flex和ChargeHR与直接观察到的步数一致性良好(组内相关系数0.86,95%置信区间0.76~0.93),但两款设备都低估了步数。样本较小,家中测试以另一设备为参照,因此更说明稳定性,而不是精确的准确度。

证据类型

测量验证研究/综述

解读依据

公开摘要

阅读重点

参照与测量误差

研究在问什么

许多老年人久坐,健身追踪器或许有助于鼓励他们多活动,但老年人的步态不同,追踪器未必能准确计步。作者在实验室和家庭中检验了两款Fitbit对老年人步数的信度与效度。

研究了谁,如何研究

效度验证研究。参与者佩戴健身追踪器(Fitbit Flex和ChargeHR)完成两次2分钟步行测试(2MWT),全程录像以便直接数步。随后在家佩戴一款追踪器和一个GENEactiv加速度计14天。31人完成了两次2MWT,30人完成了自由活动部分。一致性用组内相关系数(ICC)和斯皮尔曼相关评价。摘要未报告参与者年龄,也未报告低估的幅度。

主要发现

以下为作者报告的结果。数字须连同人群和不确定性一起阅读。

  1. 1
    与直接观察的步数相比,追踪器的标准效度较高(ICC 0.86,95%置信区间0.76~0.93),但两款设备都低估了步数。
  2. 2
    两次步行测试之间,每款设备的重测信度都很高(ICC不低于0.75),其中ChargeHR尤其好。
  3. 3
    在家中,追踪器记录的总距离和步数,与GENEactiv测得的中高强度活动一致性较好(斯皮尔曼相关系数分别为0.78和0.74)。

局限与不确定性

  1. 1
    实验室测试仅31人、家庭阶段仅30人,估计不够精确,也不能代表所有老年人。
  2. 2
    2分钟步行很短,不能涵盖缓慢拖步或做家务等日常活动。
  3. 3
    家中是用加速度计作参照,它本身也是估计值,并非真实步数。
  4. 4
    本解读仅基于摘要。

对日常健康的启示

这两款追踪器对老年人的记录比较稳定,可反映步数的相对变化,但在实验室里记录的步数少于实际步数。适合用来看自己是否比以前多动,而不是追求某个精确数字。

如何联系自己的数据

请始终使用同一追踪器、戴在同一只手腕上,比较每周步数趋势。这两款型号在实验室中倾向于低估,所以绝对步数可能低于实际,但随时间的变化仍然有意义。

如何理解这类证据

一致性取决于设备、固件、参照、人群和场景。相关性不等于一致性;验证某个指标不等于已证明诊断或治疗获益。

作者的结构化摘要 English

以下英文摘要按记录的开放许可转载,属于作者原始材料,不是 MoveVitals 的解读。上方已提供研究解读,分别说明作者结果与本站解释;重要结论可直接核对原文。

Background

Two-thirds of older Australians are sedentary. Fitness trackers have been popular with younger people and may encourage older adults to become more active. Older adults may have different gait patterns and as such it is important to establish whether fitness trackers are valid and reliable for this population. The aim of the study was to test the reliability and validity of two fitness trackers (Fitbit Flex and ChargeHR) by step count when worn by older adults. Reliability and validity were tested in two conditions: 1) in the laboratory using a two-minute-walk-test (2MWT) and 2) in a free-living environment.

Methods

Two 2MWTs were completed while wearing the fitness trackers. Participants were videoed during each test. Participants were then given one fitness tracker and a GENEactiv accelerometer to wear at home for 14-days.

Results

Thirty-one participants completed two 2MWTs and 30 completed the free-living procedure. Intra Class Correlation's of the fitness trackers with direct observation of steps (criterion validity) was high (ICC:0.86,95%CI:0.76,0.93). However, both fitness trackers underestimated steps. Excellent test-retest reliability (ICC ≥ 0.75) was found between the two 2MWTs for each device, particularly the ChargeHR devices. Good strength of agreement was found for total distance and steps (fitness tracker) and moderate-to-vigorous physical activity (GENEactiv) for the free-living environment (Spearman Rho's 0.78 and 0.74 respectively).

Conclusion

Reliability and validity of the Flex and ChargeHR when worn by older adults is good, however both devices underestimated step count within the laboratory environment. These fitness trackers appear suitable for consumer use and promoting physical activity for older adults.

来源与署名

Reliability and validity of two fitness tracker devices in the laboratory and home environment for older community-dwelling people.

Burton E, Hill KD, Lautenschlager NT, Thøgersen-Ntoumani C, Lewin G, Boyle E, Howie E.

BMC geriatrics · 2018-05-03

DOI: 10.1186/s12877-018-0793-4 ↗PubMed · 29724191 ↗Europe PMC · 记录的开放许可: cc by ↗

摘要版权归原作者,依据来源记录的开放许可转载。中文译文辅助阅读,英文摘要用于核对术语与具体数值;本站的方法学解释与作者结论分别呈现。

MoveVitals 编辑解读 · 健康教育内容 · 未记录个人临床审阅

来源核验日期 2026-11-01

实用健康指南

放在一起读

·队列研究

加速度计处理方法不同,身体活动与卒中、心肌梗死的关联曲线也不同

在英国生物银行中,基线无心血管疾病的90237名成年人随访至2022年12月,共发生1298例卒中和2031例心肌梗死;中高强度身体活动(MVPA)与这两种结局的关联曲线形状,取决于加速度计数据的处理方法。就卒中而言,只有机器学习法得到直线下降的风险;就心肌梗死而言,机器学习法和LFENMO法呈曲线下降,活动计数法呈直线下降。摘要没有给出风险比,只能说明不同方法的结论不一致,不能说明哪种方法更正确,而且这些只是观察性关联。

Preventive Medicine

重点论文精讲阅读论文 →
·测量验证研究/综述

智能手表数据能当“证人”吗:心率验证得最充分,其余证据参差

一项围绕数字取证展开的系统评价和荟萃分析,梳理了四大主流品牌智能手表的验证研究,发现心率是研究最多、也最准确的指标。步数、距离、能量消耗、活动分类和睡眠的验证不够一致,结果因品牌、方案和报告方式而异。摘要没有给出汇总数据,且多数研究是在健康人群中、于实验室内完成的,所以无法说明某一块手表对某个人在日常生活中的表现。

Forensic Science International

重点论文精讲阅读论文 →
·综述的综述

活动追踪器:每天多走约1800步,对其他健康指标影响较小

这项伞形综述汇总了39篇系统评价和荟萃分析,涉及163992名参与者;结果显示使用活动追踪器与身体活动增加相关(标准化均数差SMD为0.3–0.6),相当于每天多走约1800步、多步行40分钟,体重减轻约1公斤。对血压、胆固醇、糖化血红蛋白、生活质量和疼痛的影响通常很小,且多数不显著。摘要没有说明这些项目里追踪器还搭配了什么,也没有说明各评价之间重叠多少,因此不能把效果完全归功于设备本身。

The Lancet Digital Health

重点论文精讲阅读论文 →
·测量验证研究/综述

七款睡眠追踪设备:识别睡着很准,识别醒着和睡眠分期较差

在睡眠实验室里,34名健康的年轻成年人连续三晚佩戴七款消费级睡眠追踪设备中的若干款。与多导睡眠监测相比,所有设备识别睡眠都很准(灵敏度均不低于0.93),但识别清醒较差(特异度0.18–0.54),七款中有五款与研究用活动记录仪(特异度0.39)持平或更好;睡眠分期的估计结果不稳定。受试者是18至35岁的健康成年人,卧床时间固定为8小时,每款设备只在其中11至20人身上测试,因此对有睡眠问题的人几乎没有参考价值。

Sleep

重点论文精讲阅读论文 →
可穿戴与测量科学 →