Cómo interpretar la evidencia

Validation is specific to a metric, model, reference and setting. A useful heart-rate measurement does not validate calorie estimates or sleep stages. Even processing the same accelerometer data differently can change estimated activity–disease relationships.

Explorar artículos

131 artículos

Restablecer
·Revisión de evidencia

Children with chronic disease generally fall short of 60 active minutes a day

Across 25 accelerometer studies, children and adolescents with heart, lung, diabetes or cancer conditions generally did less than the recommended 60 minutes a day of moderate-to-vigorous activity, and mostly matched healthy peers except those with malignancies (SMD -2.2, 95% CI -4.08 to -0.26). That malignancy result rests on only 2 studies (n = 90), and the other comparisons were not significant.

PloS one

Lectura estructuradaLeer estudio →
·Estudio/revisión de validación

Seven wrist devices: heart rate mostly within 5% error, calorie estimates far off

Sixty adults wore seven wrist-worn devices while sitting, walking, running and cycling in a laboratory. Median heart rate error against an electrocardiogram (ECG) ran from 1.8% on the bike to 5.5% walking, but no device achieved a calorie error below 20 percent (device medians from 27.4% to 92.6%). These were consumer models on sale at the time, tested in a lab, so the results do not rank today's watches or show how they perform in daily life.

Journal of Personalized Medicine

Explicaciones detalladasLeer estudio →
·Estudio/revisión de validación

Apple Watch, Fitbit and Garmin heart rate and calorie accuracy varied with exercise intensity

In 62 people on a treadmill, heart rate error (MAPE) was 1.14% to 6.70% for the Apple Watch, 2.38% to 16.99% for the Fitbit Charge HR and 7.87% to 24.38% for the Garmin Forerunner 225, while calorie error was far larger on all three. These are older wrist devices tested in a short lab session, so they do not describe current models or daily life.

JMIR mHealth and uHealth

Lectura estructuradaLeer estudio →
·Artículo de investigación

Arm-worn ECG and pulse sensor prototype estimated blood pressure to within about 4 mmHg

An armband prototype combining ECG and pulse (PPG) sensors estimated systolic blood pressure with a mean error of 1.63 ± 4.44 mmHg on unseen data and heart rate with a mean absolute error of 0.21 beats per min. Data came from only ten volunteers, so this is a proof of concept and not evidence that it is accurate enough for real-world use.

Biomedical engineering online

Lectura estructuradaLeer estudio →