Idea principal
Across 26 studies, wearable approaches combining several signals had a pooled accuracy of 81.94% for detecting anxiety, versus 76.85% for single signals, with electrocardiography the best single signal (80.34% across 12 studies). Few single-sensor studies and varied methods mean the comparison is rough, and accuracy in research settings may not carry over to daily life.
Study design
Revisión de evidencia
Reading basis
Published abstract
Reading focus
Design & applicability
Esta explicación editorial está disponible en inglés, chino simplificado y chino tradicional. Esta interfaz muestra la lectura en inglés.
Pregunta de investigación
Interest is growing in using signals from wearables, such as heart activity, breathing, skin conductance and optical pulse sensing, to spot anxiety. The authors reviewed how these signals, alone and combined, have been used to detect anxiety, and how accurate the results are.
Población y método
Systematic review of 26 studies published between 2014 and 2024 that used wearable devices to collect signals for anxiety detection. The authors extracted study design, signal types, features, classification methods and accuracy outcomes, and calculated pooled accuracies to compare single-signal and multi-signal approaches. The abstract does not report participant numbers, how anxiety was defined or whether results were tested on new participants.
Resultados
The authors’ reported results. Read each estimate with its population and uncertainty.
- 1Approaches combining multiple signals outperformed single-signal ones, with pooled accuracy of 81.94% versus 76.85%.
- 2Electrocardiography was the most reliable single signal, with pooled accuracy of 80.34% across 12 studies.
- 3The authors caution that few single-sensor studies and methodological variability limit any claim that one signal is best.
- 4Common features were mean heart rate and heart rate variability for electrocardiography, the mean inspiratory-to-expiratory time ratio for respiration, mean skin conductance for electrodermal activity and mean heart rate for photoplethysmography. Support vector machine was the most used classifier.
Límites e incertidumbre
- 1Pooled accuracies average across studies with different tasks, labels and methods, so the 5-point gap between multi-signal and single-signal approaches is only indicative.
- 2Accuracy alone does not show how well anxious and non-anxious states are separated when one is much rarer, and the abstract reports no sensitivity or specificity.
- 3The authors call for larger samples and more diverse contexts, implying that many studies were small and conducted in narrow settings.
- 4This reading is based on the abstract only.
Relevancia práctica
Heart and skin signals from wearables carry some information about anxiety, and using several signals together appears to work better than one. This is not a validated way to diagnose or monitor an anxiety disorder, and a high or low reading does not tell you how anxious you are. If anxiety affects your life, talk to a clinician.
Tus datos
Resting heart rate and HRV from your wearable can be tracked over time alongside notes on stress or mood, using the same device and similar conditions. Treat shifts as context for how you feel, not as a measure of anxiety.
Cómo interpretar la evidencia
Check which designs were included, how searches and bias assessment were conducted, and the last search date. Publication date alone does not make the underlying evidence current.
Resumen estructurado de los autores English
El resumen original en inglés se reproduce con atribución bajo la licencia indicada. Es una fuente, no una interpretación de MoveVitals. El análisis preparado figura arriba; verifica los resultados importantes en la fuente.
Background
There is growing interest in using biosignals from wearable devices to assess anxiety disorders. Among these, electrocardiography is the most widely used due to its ability to monitor cardiovascular activity. Other signals, such as respiratory, electrodermal activity, and photoplethysmography, also show promise. This review aims to evaluate how these signals, individually and in combination, have been used for anxiety detection.
Methods
We systematically reviewed 26 studies published between 2014 and 2024 that used wearable devices to collect signals for anxiety detection. Extracted information included study design, signal types, features, classification methods, and accuracy outcomes. Pooled accuracies were calculated to compare single-signal and multi-signal approaches.
Results
Here we show that approaches combining multiple signals outperform those using a single signal, with a pooled accuracy of 81.94% compared to 76.85%. Electrocardiography was the most reliable individual signal, with a pooled accuracy of 80.34% across 12 studies. However, the limited number of single-sensor studies and methodological variability limit conclusions about the superiority of any one modality. The most common features included mean heart rate and heart rate variability for electrocardiography, the mean inspiratory-to-expiratory time ratio for respiratory signals, mean skin conductance for electrodermal activity, and the mean heart rate for photoplethysmography. Support vector machine was the predominant classifier.
Conclusions
This review underscores the clinical potential of wearable devices for anxiety detection, emphasizing the value of multimodal approaches. Future research should focus on refining algorithms, expanding sample sizes, and exploring diverse contexts to improve the accuracy and generalizability of these methods.
Fuentes y atribución
Wearable devices for anxiety assessment: a systematic review.
Elgendi M, Markov K, Liu H, De Vos M, Khalaf K, Khandoker A, Jelinek HF, Goswami D, Menon C.
Communications medicine · 2026-01-09
DOI: 10.1038/s43856-025-01234-6 ↗PubMed · 41513763 ↗Europe PMC · Licencia registrada: cc by ↗Abstract © the original authors, reproduced under the recorded open licence. Translations support reading; use the English record to check terminology and numerical results. Our methodological interpretation is separate from the authors’ conclusions.
Interpretación editorial de MoveVitals · contenido educativo · sin revisión clínica individual registrada
Fuentes verificadas 2026-11-01
Guías prácticas
Leer en contexto
Activity–stroke and heart attack curves differ by accelerometer processing method
Among 90,237 UK Biobank adults free of cardiovascular disease at baseline, followed until December 2022 for 1,298 strokes and 2,031 myocardial infarctions, the shape of the link between moderate-vigorous physical activity (MVPA) and each outcome depended on how the accelerometer data were processed. For stroke, hazard fell in a straight line only with the machine-learning metric; for myocardial infarction, two metrics gave a curved decline and activity counts a straight one. The abstract gives no hazard ratios, so it shows that methods disagree, not which one is right, and the findings are observational associations.
Preventive Medicine
Smartwatch data as forensic evidence: heart rate is best validated, the rest uneven
A systematic review and meta-analysis of studies on smartwatches from four major brands, framed around digital forensics, found that heart rate was both the most studied and the most accurate measure. Step count, distance, energy expenditure, activity classification and sleep were less consistently validated, and results varied by brand, protocol and reporting. The abstract gives no pooled numbers, and most studies were run in healthy people in laboratories, so it cannot say how a particular watch performs for a particular person in daily life.
Forensic Science International
Activity trackers: about 1,800 more steps a day, but small effects on other outcomes
An umbrella review of 39 systematic reviews and meta-analyses, covering 163,992 participants, found that activity trackers were associated with more physical activity (SMD 0.3–0.6), equating to about 1,800 extra steps and 40 minutes more walking per day, and with a bodyweight reduction of about 1 kg. Effects on blood pressure, cholesterol, glycosylated haemoglobin, quality of life and pain were typically small and often non-significant. The abstract does not say what else came with the trackers in these programs or how much the reviews overlap, so the gains cannot be credited to the device alone.
The Lancet Digital Health
Seven sleep trackers: good at spotting sleep, weak on wake and sleep stages
In a sleep laboratory, 34 healthy young adults wore a subset of seven consumer sleep trackers for three nights. Against polysomnography every device detected sleep very well (sensitivity 0.93 or higher) but caught wake poorly (specificity 0.18–0.54), and five of the seven matched or beat research actigraphy (specificity 0.39). Sleep-stage estimates were inconsistent, and the participants were healthy adults aged 18 to 35 in a fixed 8-hour bed window, with each device tested in only 11 to 20 of them, so the results say little about people with sleep problems.
Sleep