Wearable sensors can tell frailty stages apart in older adults, mainly via activity and gait speed

Colectivo editorial MoveVitals · Study published · Reading updated

Original paper:How wearable sensors have been utilised to evaluate frailty in older adults: a systematic review. · Journal of neuroengineering and rehabilitation · 2021 · Artículo original ↗

Idea principal

Across 29 studies of community-dwelling adults over 60, all but one found an association between physical activity measured by wearables and frailty level, and every study reporting gait speed found it correlated with frailty. The studies used 13 different sensors in 8 body locations, so no single device or placement is yet established.

Study design

Revisión de evidencia

Reading basis

Published abstract

Reading focus

Design & applicability

Esta explicación editorial está disponible en inglés, chino simplificado y chino tradicional. Esta interfaz muestra la lectura en inglés.

Pregunta de investigación

Frailty, an age-related condition that raises the risk of bad outcomes, is estimated to affect 16% of community-dwelling people worldwide. The authors wanted to see how wearable sensors have been used to assess frailty in older adults and which measurements were most common.

Población y método

Systematic review of primary observational studies found in Medline, Science Direct, Scopus and CINAHL, searched between March 2020 and November 2020, limited to English articles published from January 2010 to November 2020. Studies had to involve adults aged over 60, use a wearable sensor to quantify physical activity or mobility, and include a frailty measure. Quality was assessed with the Appraisal Tool for Cross-sectional Studies (AXIS). The abstract does not report total participant numbers.

Resultados

The authors’ reported results. Read each estimate with its population and uncertainty.

  1. 1
    Twenty-nine studies were included. They used 13 different body-worn sensors in 8 body locations, with participants who were community-dwelling older adults, in home, laboratory or hospital settings.
  2. 2
    The most frequently measured parameters were postural transitions, number of steps, percentage of time in physical activity and intensity of physical activity, followed closely by gait speed.
  3. 3
    All but one study showed an association between physical activity and level of frailty.
  4. 4
    All reports of gait speed indicated a correlation with frailty.

Límites e incertidumbre

  1. 1
    The studies are observational and, judged by the cross-sectional appraisal tool, mostly capture a single time point, so they show association rather than whether sensor data predict who becomes frail.
  2. 2
    With 13 sensors in 8 locations, the abstract gives no pooled accuracy or cutoff values that could guide choosing a device.
  3. 3
    Participants were community-dwelling older adults only, so findings may not apply to people in care homes or to younger adults.
  4. 4
    This reading is based on the abstract only.

Relevancia práctica

Slower walking and less or lower-intensity activity went together with greater frailty in these studies, which fits what clinicians already look for. This does not turn a consumer tracker into a frailty test, and a drop in steps has many possible causes. If you worry about an older relative, discuss it with their clinician.

Tus datos

Daily steps, time in activity and walking speed from a wearable are the same kinds of measures used in these studies. Compare against the person's own earlier numbers with the same device and wearing position, and watch for sustained declines over weeks rather than single days.

Cómo interpretar la evidencia

Check which designs were included, how searches and bias assessment were conducted, and the last search date. Publication date alone does not make the underlying evidence current.

Resumen estructurado de los autores English

El resumen original en inglés se reproduce con atribución bajo la licencia indicada. Es una fuente, no una interpretación de MoveVitals. El análisis preparado figura arriba; verifica los resultados importantes en la fuente.

Background

Globally the population of older adults is increasing. It is estimated that by 2050 the number of adults over the age of 60 will represent over 21% of the world's population. Frailty is a clinical condition associated with ageing resulting in an increase in adverse outcomes. It is considered the greatest challenge facing an ageing population affecting an estimated 16% of community-dwelling populations worldwide.

Aim

The aim of this systematic review is to explore how wearable sensors have been used to assess frailty in older adults.

Method

Electronic databases Medline, Science Direct, Scopus, and CINAHL were systematically searched March 2020 and November 2020. A search constraint of articles published in English, between January 2010 and November 2020 was applied. Papers included were primary observational studies involving; older adults aged > 60 years, used a wearable sensor to provide quantitative measurements of physical activity (PA) or mobility and a measure of frailty. Studies were excluded if they used non-wearable sensors for outcome measurement or outlined an algorithm or application development exclusively. The methodological quality of the selected studies was assessed using the Appraisal Tool for Cross-sectional Studies (AXIS).

Results

Twenty-nine studies examining the use of wearable sensors to assess and discriminate between stages of frailty in older adults were included. Thirteen different body-worn sensors were used in eight different body-locations. Participants were community-dwelling older adults. Studies were performed in home, laboratory or hospital settings. Postural transitions, number of steps, percentage of time in PA and intensity of PA together were the most frequently measured parameters followed closely by gait speed. All but one study demonstrated an association between PA and level of frailty. All reports of gait speed indicate correlation with frailty.

Conclusions

Wearable sensors have been successfully used to evaluate frailty in older adults. Further research is needed to identify a feasible, user-friendly device and body-location that can be used to identify signs of pre-frailty in community-dwelling older adults. This would facilitate early identification and targeted intervention to reduce the burden of frailty in an ageing population.

Fuentes y atribución

How wearable sensors have been utilised to evaluate frailty in older adults: a systematic review.

Vavasour G, Giggins OM, Doyle J, Kelly D.

Journal of neuroengineering and rehabilitation · 2021-07-08

DOI: 10.1186/s12984-021-00909-0 ↗PubMed · 34238323 ↗Europe PMC · Licencia registrada: cc by ↗

Abstract © the original authors, reproduced under the recorded open licence. Translations support reading; use the English record to check terminology and numerical results. Our methodological interpretation is separate from the authors’ conclusions.

Interpretación editorial de MoveVitals · contenido educativo · sin revisión clínica individual registrada

Fuentes verificadas 2026-11-01

Guías prácticas

Leer en contexto

·Estudio de cohorte

Activity–stroke and heart attack curves differ by accelerometer processing method

Among 90,237 UK Biobank adults free of cardiovascular disease at baseline, followed until December 2022 for 1,298 strokes and 2,031 myocardial infarctions, the shape of the link between moderate-vigorous physical activity (MVPA) and each outcome depended on how the accelerometer data were processed. For stroke, hazard fell in a straight line only with the machine-learning metric; for myocardial infarction, two metrics gave a curved decline and activity counts a straight one. The abstract gives no hazard ratios, so it shows that methods disagree, not which one is right, and the findings are observational associations.

Preventive Medicine

Explicaciones detalladasLeer estudio →
·Estudio/revisión de validación

Smartwatch data as forensic evidence: heart rate is best validated, the rest uneven

A systematic review and meta-analysis of studies on smartwatches from four major brands, framed around digital forensics, found that heart rate was both the most studied and the most accurate measure. Step count, distance, energy expenditure, activity classification and sleep were less consistently validated, and results varied by brand, protocol and reporting. The abstract gives no pooled numbers, and most studies were run in healthy people in laboratories, so it cannot say how a particular watch performs for a particular person in daily life.

Forensic Science International

Explicaciones detalladasLeer estudio →
·Revisión de revisiones

Activity trackers: about 1,800 more steps a day, but small effects on other outcomes

An umbrella review of 39 systematic reviews and meta-analyses, covering 163,992 participants, found that activity trackers were associated with more physical activity (SMD 0.3–0.6), equating to about 1,800 extra steps and 40 minutes more walking per day, and with a bodyweight reduction of about 1 kg. Effects on blood pressure, cholesterol, glycosylated haemoglobin, quality of life and pain were typically small and often non-significant. The abstract does not say what else came with the trackers in these programs or how much the reviews overlap, so the gains cannot be credited to the device alone.

The Lancet Digital Health

Explicaciones detalladasLeer estudio →
·Estudio/revisión de validación

Seven sleep trackers: good at spotting sleep, weak on wake and sleep stages

In a sleep laboratory, 34 healthy young adults wore a subset of seven consumer sleep trackers for three nights. Against polysomnography every device detected sleep very well (sensitivity 0.93 or higher) but caught wake poorly (specificity 0.18–0.54), and five of the seven matched or beat research actigraphy (specificity 0.39). Sleep-stage estimates were inconsistent, and the participants were healthy adults aged 18 to 35 in a fixed 8-hour bed window, with each device tested in only 11 to 20 of them, so the results say little about people with sleep problems.

Sleep

Explicaciones detalladasLeer estudio →
Dispositivos y medición →