Idea principal
In 22 women, nocturnal finger skin temperature from an Oura ring was 0.30 °C (SD 0.12) higher in the luteal phase than the follicular phase, and the best algorithm detected ovulation with 83.3% sensitivity. It is a small pilot study, so the accuracy may not generalize to other users.
Study design
Artículo de investigación
Reading basis
Published abstract
Reading focus
Design & applicability
Esta explicación editorial está disponible en inglés, chino simplificado y chino tradicional. Esta interfaz muestra la lectura en inglés.
Pregunta de investigación
Body temperature rises in a two-phase pattern across the menstrual cycle, which is why it is used to track cycle phases. The authors tested whether nocturnal finger skin temperature from a wearable Oura ring can monitor the cycle and predict menstruation and ovulation in everyday life.
Población y método
Ambulatory pilot study of 22 volunteer women who wore the Oura ring, confirmed ovulation with urine tests, and kept diaries of menstruation for an average of 114.7 days (SD 20.6). Oral temperature was measured right after waking over an average of 1.9 cycles (SD 1.2). Skin and oral temperatures were compared with repeated measures correlation and dependent t-tests between phases. Algorithms using skin temperature were tested for predicting the start of menstruation and ovulation, with performance judged by sensitivity and positive predictive value within different windows around the reported day.
Resultados
The authors’ reported results. Read each estimate with its population and uncertainty.
- 1Both temperatures were higher in the luteal phase than the follicular phase: by 0.30 °C (SD 0.12) for skin and 0.23 °C (SD 0.09) for oral temperature (p < 0.001).
- 2Skin and oral temperatures correlated for daily values (r = 0.563, p < 0.001) and for differences between phases (r = 0.589, p = 0.004).
- 3Menstruations were detected with sensitivity of 71.9% to 86.5% in windows of ±2 to ±4 days. The best algorithm detected ovulations with 83.3% sensitivity in the fertile window from -3 to +2 days around verified ovulation.
- 4Positive predictive values were similar to sensitivities. With the best algorithm, the mean offset of estimates was 0.4 days (SD 1.8) for menstruations and 0.6 days (SD 1.5) for ovulations.
Límites e incertidumbre
- 1Only 22 volunteers took part, so the results are preliminary, and volunteers may differ from typical users.
- 2Oral temperature was measured in only a subset of the cycles (an average of 1.9 per woman), so the comparison with skin temperature rests on limited data.
- 3The algorithms were tested on the same women who produced them, according to the abstract, and they were not tested for contraception or fertility use.
- 4Correlations of this size mean skin and oral temperatures agree only moderately. This reading is based on the abstract only.
Relevancia práctica
Nighttime ring temperature seems to follow the cycle's two-phase pattern and can estimate period start and ovulation within a few days. That is not accurate enough to rely on for preventing or planning pregnancy. For fertility questions, talk with a clinician.
Tus datos
Skin temperature from a ring is best read as a relative shift from your own baseline, not an absolute value; oral temperature will read differently. Track several cycles on the same device and compare the pattern of rise and fall rather than a single night.
Cómo interpretar la evidencia
The index does not establish a precise design. Read the methods before making causal claims; check population, comparator, outcomes and uncertainty in the source.
Resumen estructurado de los autores English
El resumen original en inglés se reproduce con atribución bajo la licencia indicada. Es una fuente, no una interpretación de MoveVitals. El análisis preparado figura arriba; verifica los resultados importantes en la fuente.
Background
Body temperature is a common method in menstrual cycle phase tracking because of its biphasic form. In ambulatory studies, different skin temperatures have proven to follow a similar pattern. The aim of this pilot study was to assess the applicability of nocturnal finger skin temperature based on a wearable Oura ring to monitor menstrual cycle and predict menstruations and ovulations in real life.
Methods
Volunteer women (n = 22) wore the Oura ring, measured ovulation through urine tests, and kept diaries on menstruations at an average of 114.7 days (SD 20.6), of which oral temperature was measured immediately after wake-up at an average of 1.9 cycles (SD 1.2). Skin and oral temperatures were compared by assessing daily values using repeated measures correlation and phase mean values and differences between phases using dependent t-test. Developed algorithms using skin temperature were tested to predict the start of menstruation and ovulation. The performance of algorithms was assessed with sensitivity and positive predictive values (true positive defined with different windows around the reported day).
Results
Nocturnal skin temperatures and oral temperatures differed between follicular and luteal phases with higher temperatures in the luteal phase, with a difference of 0.30 °C (SD 0.12) for skin and 0.23 °C (SD 0.09) for oral temperature (p < 0.001). Correlation between skin and oral temperatures was found using daily temperatures (r = 0.563, p < 0.001) and differences between phases (r = 0.589, p = 0.004). Menstruations were detected with a sensitivity of 71.9-86.5% in window lengths of ±2 to ±4 days. Ovulations were detected with the best-performing algorithm with a sensitivity of 83.3% in fertile window from - 3 to + 2 days around the verified ovulation. Positive predictive values had similar percentages to those of sensitivities. The mean offset for estimations were 0.4 days (SD 1.8) for menstruations and 0.6 days (SD 1.5) for ovulations with the best-performing algorithm.
Conclusions
Nocturnal skin temperature based on wearable ring showed potential for menstrual cycle monitoring in real life conditions.
Fuentes y atribución
Nocturnal finger skin temperature in menstrual cycle tracking: ambulatory pilot study using a wearable Oura ring.
Maijala A, Kinnunen H, Koskimäki H, Jämsä T, Kangas M.
BMC women's health · 2019-11-29
DOI: 10.1186/s12905-019-0844-9 ↗PubMed · 31783840 ↗Europe PMC · Licencia registrada: cc by ↗Abstract © the original authors, reproduced under the recorded open licence. Translations support reading; use the English record to check terminology and numerical results. Our methodological interpretation is separate from the authors’ conclusions.
Interpretación editorial de MoveVitals · contenido educativo · sin revisión clínica individual registrada
Fuentes verificadas 2026-11-01
Guías prácticas
Leer en contexto
Activity–stroke and heart attack curves differ by accelerometer processing method
Among 90,237 UK Biobank adults free of cardiovascular disease at baseline, followed until December 2022 for 1,298 strokes and 2,031 myocardial infarctions, the shape of the link between moderate-vigorous physical activity (MVPA) and each outcome depended on how the accelerometer data were processed. For stroke, hazard fell in a straight line only with the machine-learning metric; for myocardial infarction, two metrics gave a curved decline and activity counts a straight one. The abstract gives no hazard ratios, so it shows that methods disagree, not which one is right, and the findings are observational associations.
Preventive Medicine
Smartwatch data as forensic evidence: heart rate is best validated, the rest uneven
A systematic review and meta-analysis of studies on smartwatches from four major brands, framed around digital forensics, found that heart rate was both the most studied and the most accurate measure. Step count, distance, energy expenditure, activity classification and sleep were less consistently validated, and results varied by brand, protocol and reporting. The abstract gives no pooled numbers, and most studies were run in healthy people in laboratories, so it cannot say how a particular watch performs for a particular person in daily life.
Forensic Science International
Activity trackers: about 1,800 more steps a day, but small effects on other outcomes
An umbrella review of 39 systematic reviews and meta-analyses, covering 163,992 participants, found that activity trackers were associated with more physical activity (SMD 0.3–0.6), equating to about 1,800 extra steps and 40 minutes more walking per day, and with a bodyweight reduction of about 1 kg. Effects on blood pressure, cholesterol, glycosylated haemoglobin, quality of life and pain were typically small and often non-significant. The abstract does not say what else came with the trackers in these programs or how much the reviews overlap, so the gains cannot be credited to the device alone.
The Lancet Digital Health
Seven sleep trackers: good at spotting sleep, weak on wake and sleep stages
In a sleep laboratory, 34 healthy young adults wore a subset of seven consumer sleep trackers for three nights. Against polysomnography every device detected sleep very well (sensitivity 0.93 or higher) but caught wake poorly (specificity 0.18–0.54), and five of the seven matched or beat research actigraphy (specificity 0.39). Sleep-stage estimates were inconsistent, and the participants were healthy adults aged 18 to 35 in a fixed 8-hour bed window, with each device tested in only 11 to 20 of them, so the results say little about people with sleep problems.
Sleep