Idea principal
Among 354 277 Swedish adults screened through occupational health services, estimated relative VO2max fell by 10.8% between 1995 and 2017, and the share with low fitness (below 32 mL/min/kg) rose from 27% to 46%. Fitness was estimated from a submaximal cycle test in people who attended workplace screening, so the figures may not represent everyone.
Study design
Artículo de investigación
Reading basis
Published abstract
Reading focus
Design & applicability
Esta explicación editorial está disponible en inglés, chino simplificado y chino tradicional. Esta interfaz muestra la lectura en inglés.
Pregunta de investigación
Cardiorespiratory fitness is strongly linked to illness and death, yet long-term trends in the general population are poorly documented. The authors described how VO2max changed in the Swedish working population from 1995 to 2017 and whether the change differed by sex, age, education and region.
Población y método
Trend analysis of 354 277 participants (44% women, aged 18-74) who took part in a nationwide occupational health service screening between 1995 and 2017. VO2max was estimated with a submaximal cycle test. The authors report changes in standardized mean absolute (L/min) and relative (mL/min/kg) VO2max, and in the proportion with low relative VO2max (<32). The abstract does not describe how participants were recruited or what adjustments were made.
Resultados
The authors’ reported results. Read each estimate with its population and uncertainty.
- 1Absolute VO2max fell by 6.7% (0.19 L/min) across the whole group. Relative VO2max, which accounts for body weight, fell by 10.8% (4.2 mL/min/kg), and about one third of that drop was explained by a simultaneous increase in body mass.
- 2The fall in absolute fitness was larger in men than in women (8.7% vs 5.3%), in younger than older people (6.5% vs 2.3%), in people with short education than long education (11.4% vs 4.5%), and in rural than urban regions (6.5% vs 3.5%), all P<0.001.
- 3The proportion of people with low relative VO2max (below 32) rose from 27% to 46% (P<0.001).
Límites e incertidumbre
- 1VO2max was estimated from a submaximal cycle test rather than measured to exhaustion, so individual values carry error, and the trend assumes the test and the people tested stayed comparable over the period.
- 2Participants were people who attended occupational health screening. The abstract does not say how participation or the mix of employers changed over time, which could shift the averages.
- 3These are descriptive trends. Only body mass is offered as a partial explanation, so the abstract cannot say why fitness fell, and it does not define the age groups compared.
- 4Declines are reported as percent changes in standardized means, without confidence intervals for their size. This reading is based on the abstract only.
Relevancia práctica
Across this large working population, average fitness slid and low fitness became much more common (27% to 46%). These are population averages, not a verdict on any one person. The cut-off of 32 mL/min/kg is this study's definition of low relative fitness in Swedish workers, not a clinical threshold for you, and gaining body weight pulls relative VO2max down even when absolute fitness holds, so look at weight and activity together.
Tus datos
Watches and apps give a relative VO2max estimate in mL/kg/min, and it falls if your weight rises even when your absolute fitness holds. Compare your own estimate over months on the same device, next to weight and weekly activity, rather than against one cut-off such as 32, because device estimates differ from the cycle test used here.
Cómo interpretar la evidencia
The index does not establish a precise design. Read the methods before making causal claims; check population, comparator, outcomes and uncertainty in the source.
Resumen estructurado de los autores English
El resumen original en inglés se reproduce con atribución bajo la licencia indicada. Es una fuente, no una interpretación de MoveVitals. El análisis preparado figura arriba; verifica los resultados importantes en la fuente.
Background
Long-term trend analyses of cardiorespiratory fitness (VO_(2) max) in the general population are limited.
Objectives
To describe trends in VO_(2) max from 1995 to 2017 in the Swedish working force and to study developments across categories of sex, age, education, and geographic regions.
Methods
A total of 354 277 participants (44% women, 18-74 years) who participated in a nationwide occupational health service screening between 1995 and 2017 were included. Changes in standardized mean values of absolute (L/min) and relative (mL/min/kg) VO_(2) max, and the proportion with low (<32) relative VO_(2) max are reported. VO_(2) max was estimated using a submaximal cycle test.
Results
Absolute VO_(2) max decreased by -6.7% (-0.19 L/min) in the total population. Relative VO_(2) max decreased by -10.8% (-4.2 mL/min/kg) with approximately one-third explained by a simultaneous increase in body mass. Decreases in absolute fitness were more pronounced in men vs women (8.7% vs 5.3%), in younger vs older (6.5% vs 2.3%), in short (11.4%) vs long (4.5%) education, and in rural vs urban regions (6.5% vs 3.5%), all P < 0.001. The proportions with low VO_(2) max increased from 27% to 46% (P < 0.001).
Conclusion
Between 1995 and 2017, there was a steady and pronounced decline in mean cardiorespiratory fitness in Swedish adults. Male gender, young age, short education, and living in a rural area were predictive of greater reductions. The proportion with low cardiorespiratory fitness almost doubled. Given the strong associations between cardiorespiratory fitness and multiple morbidities and mortality, preventing further decreases is a clear public health priority, especially for vulnerable groups.
Fuentes y atribución
Decline in cardiorespiratory fitness in the Swedish working force between 1995 and 2017.
Ekblom-Bak E, Ekblom Ö, Andersson G, Wallin P, Söderling J, Hemmingsson E, Ekblom B.
Scandinavian journal of medicine & science in sports · 2018-11-15
DOI: 10.1111/sms.13328 ↗PubMed · 30351472 ↗Europe PMC · Licencia registrada: cc by ↗Abstract © the original authors, reproduced under the recorded open licence. Translations support reading; use the English record to check terminology and numerical results. Our methodological interpretation is separate from the authors’ conclusions.
Interpretación editorial de MoveVitals · contenido educativo · sin revisión clínica individual registrada
Fuentes verificadas 2026-11-01
Guías prácticas
Leer en contexto
Disrupted daily rest-activity rhythm is linked to higher mortality in 109,365 people
Across seven observational studies with 109,365 participants, a weaker day-night activity contrast (lower relative amplitude) was associated with higher cardiovascular mortality (hazard ratio [HR] 1.50, 95% CI 1.13 to 1.98) and all-cause mortality (HR 1.46, 95% CI 1.27 to 1.68). The evidence base is small and observational, so it cannot show that improving the rhythm lowers risk, and illness may itself disturb the rhythm.
Journal of the American Heart Association
Five exercise types lowered resting blood pressure, isometric training the most
Pooling 270 randomised trials with 15,827 participants, aerobic, resistance, combined, interval and isometric training all lowered resting blood pressure compared with non-intervention controls (P<0.001 for each), with the largest fall for isometric training: 8.24 mm Hg systolic and 4.00 mm Hg diastolic. The ranking between modes is partly indirect and the trials differ, so it is not a personal prescription.
British Journal of Sports Medicine
A salt substitute lowered stroke, major cardiovascular events and death in rural China
In 20,995 people in 600 rural Chinese villages who had a history of stroke or were 60 or older with high blood pressure, a salt substitute (75% sodium chloride, 25% potassium chloride) lowered the stroke rate versus regular salt over a mean 4.74 years: 29.14 versus 33.65 events per 1000 person-years (rate ratio 0.86, 95% CI 0.77 to 0.96; P = 0.006). Death was also lower (rate ratio 0.88) and serious hyperkalemia events were not significantly higher, but the trial was open-label and set in rural China.
The New England Journal of Medicine
Apple Watch irregular-pulse alerts were rare; 34% of those tested had atrial fibrillation
Among 419,297 Apple Watch users with no known atrial fibrillation (AF), 0.52% received an irregular-pulse alert, and 34% of the 450 who returned a usable ECG patch had AF (97.5% CI 29 to 39). Alerts that coincided with patch recording matched AF with a positive predictive value of 0.84 (95% CI 0.76 to 0.92), but only 20.8% of alerted people returned a patch and nobody without an alert was monitored, so a quiet watch does not rule AF out.
The New England Journal of Medicine