Saltar al contenido
RecuperaciónArtículo de investigación3 min read

Very slow heart rate variability falls as treadmill running gets harder and longer

Colectivo editorial MoveVitals · Study published · Reading updated

Original paper:Changes in heart rate variability with respect to exercise intensity and time during treadmill running. · Biomedical engineering online · 2018 · Artículo original ↗

Idea principal

In 21 healthy men, ultra-low and very-low frequency HRV power was lower during moderate than at rest, and lower again during vigorous treadmill running, with further declines over the 45-minute runs. The sample was only young healthy men, and the authors say they cannot tell whether the time effect is time itself or rising heart rate.

Study design

Artículo de investigación

Reading basis

Published abstract

Reading focus

Design & applicability

Esta explicación editorial está disponible en inglés, chino simplificado y chino tradicional. Esta interfaz muestra la lectura en inglés.

Pregunta de investigación

The ultra-low (ULF) and very-low frequency (VLF) parts of heart rate variability (HRV) are involved in how heart rate is controlled but have rarely been studied. The authors measured how they change with exercise intensity and with time during running.

Población y método

Experimental study in 21 healthy male participants. RR intervals were recorded by ECG at rest and during moderate and vigorous-intensity treadmill running, each test lasting 45 min. For moderate and vigorous running, the constant-speed stage was divided into three consecutive windows of equal length, about 14 min each. ULF and VLF power were computed with Lomb-Scargle power spectral density estimates. The abstract's P values and some other values did not come through in the text available.

Resultados

The authors’ reported results. Read each estimate with its population and uncertainty.

  1. 1
    For both ULF and VLF, mean power differed significantly between rest, moderate and vigorous intensity, and was lower for moderate than rest, vigorous than rest, and vigorous than moderate.
  2. 2
    At moderate intensity, mean power differed significantly across the three time windows for both bands, with lower power in later windows than in earlier ones.
  3. 3
    At vigorous intensity, ULF power did not differ significantly across the three windows, but VLF power did, again lower in later windows.

Límites e incertidumbre

  1. 1
    Only 21 healthy men were studied, so the findings may not apply to women, older adults, trained athletes or people with heart disease.
  2. 2
    The authors could not separate the effect of time from rising heart rate due to cardiovascular drift, so the time effect has no clear cause.
  3. 3
    Each person ran at fixed moderate and vigorous speeds on a treadmill, so results may differ outdoors or at other intensities.
  4. 4
    This reading is based on the abstract only, and the abstract text lacked the specific P values.

Relevancia práctica

HRV drops as exercise intensity rises, and it also appears to keep dropping during a long steady effort. Nothing here shows that a lower value during a run signals a problem. The authors' own suggestion concerns feedback-control applications, not training advice.

Tus datos

Wearable HRV during a workout reflects effort and duration, so it should not be compared with your resting or overnight HRV. If you look at in-workout HRV, compare only sessions of the same intensity and length, from the same device, and note that the very slow bands studied here are not what most apps report.

Cómo interpretar la evidencia

The index does not establish a precise design. Read the methods before making causal claims; check population, comparator, outcomes and uncertainty in the source.

Resumen estructurado de los autores English

El resumen original en inglés se reproduce con atribución bajo la licencia indicada. Es una fuente, no una interpretación de MoveVitals. El análisis preparado figura arriba; verifica los resultados importantes en la fuente.

Background

Heart rate variability (HRV) arises from the complex interplay of sympathetic and parasympathetic autonomic regulation of heart rate. Ultra-low frequency (ULF) and very-low frequency (VLF) components of HRV play a crucial role in automatic HR controllers, but these frequency bands have hitherto largely been neglected in HRV studies. The aim of this work was to investigate changes in ULF and VLF heart rate variability with respect to exercise intensity and time during treadmill running.

Methods

RR intervals were determined by ECG in 21 healthy male participants at rest, and during moderate and vigorous-intensity treadmill running; each of these three tests had a duration of 45 min. Time dependence of HRV was investigated for moderate and vigorous running intensities by dividing the constant-speed stages into three consecutive windows of equal duration ([Formula: see text] 14 min), denoted [Formula: see text], [Formula: see text] and [Formula: see text]. ULF and VLF power were computed using Lomb-Scargle power spectral density estimates.

Results

For both the ULF and VLF frequency bands, mean power was significantly different between the resting, moderate and vigorous intensity levels (overall [Formula: see text]): mean power was lower for moderate vs. rest ([Formula: see text]), for vigorous vs. rest ([Formula: see text]), and for vigorous vs. moderate ([Formula: see text]). For both ULF and VLF and moderate intensity, mean power was significantly different between the three time windows (overall [Formula: see text] for ULF, overall [Formula: see text] for VLF): for ULF, mean power was lower for [Formula: see text] vs. [Formula: see text] ([Formula: see text]) and for [Formula: see text] vs. [Formula: see text] ([Formula: see text]); for VLF, mean power was lower for [Formula: see text] vs. [Formula: see text] ([Formula: see text]). For ULF and vigorous intensity, there was no significant difference in mean power between the three time windows (overall [Formula: see text]). For VLF and vigorous intensity, mean power was significantly different between [Formula: see text], [Formula: see text] and [Formula: see text] (overall [Formula: see text]): mean power was lower for [Formula: see text] vs. [Formula: see text] ([Formula: see text]) and for [Formula: see text] vs. [Formula: see text] ([Formula: see text]).

Conclusions

The degree of HRV in terms of ULF and VLF power was found to decrease with increasing intensity of exercise. HRV was also observed to decrease over time, but it remains to clarify whether these changes are due to time itself or to increases in HR related to cardiovascular drift. For feedback control applications, attention should be focused on meeting performance targets at low intensity and during the early stages of exercise.

Fuentes y atribución

Changes in heart rate variability with respect to exercise intensity and time during treadmill running.

Hunt KJ, Saengsuwan J.

Biomedical engineering online · 2018-09-24

DOI: 10.1186/s12938-018-0561-x ↗PubMed · 30249267 ↗Europe PMC · Licencia registrada: cc by ↗

Abstract © the original authors, reproduced under the recorded open licence. Translations support reading; use the English record to check terminology and numerical results. Our methodological interpretation is separate from the authors’ conclusions.

Interpretación editorial de MoveVitals · contenido educativo · sin revisión clínica individual registrada

Fuentes verificadas 2026-11-01

Guías prácticas

Leer en contexto

·Artículo de investigación

Short-term HRV was higher during slow breathing in 962 military men, injured or not

In 962 military men (median age 37.6 years), every short-term heart rate variability (HRV) measure was higher during slow breathing at six breaths a minute than during spontaneous breathing, injured or not; in fast resting breathers RMSSD rose from 15.57 to 21.89 ms. It was one session in a fixed order, so it shows an immediate effect, not lasting benefit.

European Journal of Applied Physiology

Explicaciones detalladasLeer estudio →
·Metaanálisis de ensayos

Cold-water immersion: no strength gain, briefly weaker jumps, soreness relief uncertain

Across 22 randomised trials (375 participants, mostly men), one cold-water immersion after exercise did not change maximal isometric strength (g 0.08, 95% CI −0.11 to 0.26) and was followed by weaker jumping straight afterwards (g −0.68), gone by 24–48 hours. Lower soreness and creatine kinase looked favourable but weakened in sensitivity checks, and certainty was low to very low.

PeerJ

Explicaciones detalladasLeer estudio →
·Revisión de evidencia

Cold-water immersion after hard exercise: less soreness, better power, no strength gain

In a meta-analysis of 52 randomised trials, cold-water immersion after high-intensity exercise was followed 24 hours later by lower soreness (SMD −0.89), higher perceived recovery (0.66) and better muscular power (0.22), with no effect on strength. Participants could not be blinded, most were men, and many pooled results rest on few studies with high heterogeneity.

Sports Medicine

Explicaciones detalladasLeer estudio →
·Métodos e interpretación

Acute:chronic workload ratio: no evidence it can reduce injury risk, authors argue

The authors argue there is no evidence for using the acute:chronic workload ratio (ACWR) in training-load management or to reduce injury risk: no study has properly estimated a causal effect, and the ratio is statistically inaccurate and ambiguous. This is a methodological critique, not a new data analysis, so it does not show that training load is unrelated to injury.

International Journal of Sports Physiology and Performance

Explicaciones detalladasLeer estudio →
Recuperación →