Idea principal
In 89 older adults (average age 73.7 years), the International Physical Activity Questionnaire (IPAQ) showed weak reliability and poor validity for sitting time and moderate-vigorous activity against a thigh-worn accelerometer, and classified behaviour correctly only 2% of the time. The sample was small, so the finding is a caution about questionnaires rather than a precise error estimate.
Study design
Estudio/revisión de validación
Reading basis
Published abstract
Reading focus
Reference & error
Esta explicación editorial está disponible en inglés, chino simplificado y chino tradicional. Esta interfaz muestra la lectura en inglés.
Pregunta de investigación
Questionnaires are a cheap way to estimate how much older people sit and move, but they depend on memory. The authors tested how repeatable the IPAQ is, and how well it agrees with an accelerometer, for sedentary behaviour and moderate-vigorous physical activity, and whether men and women differ.
Población y método
Validation study of 89 participants (73.7 ± 6.3 years, 54% female). Each completed the IPAQ, wore a thigh-mounted triaxial accelerometer (GeneActiv Original) for seven consecutive days, and then completed the IPAQ a second time. Reliability compared the two questionnaires; validity compared the IPAQ with accelerometer cut-off points for total sedentary behaviour, 10-minute moderate-vigorous activity (bouts of at least 10 continuous minutes) and sporadic moderate-vigorous activity (bouts under 10 minutes). Sex differences were examined. The abstract does not report the correlation values.
Resultados
The authors’ reported results. Read each estimate with its population and uncertainty.
- 1The IPAQ showed weak reliability for total sitting time (hours per week) and for 10-minute moderate-vigorous activity.
- 2Concurrent validity against the accelerometer was poor for total sitting time and 10-minute moderate-vigorous activity, but not for sporadic moderate-vigorous activity.
- 3The IPAQ classified participants' physical behaviour correctly only 2% of the time.
- 4Sex differences appeared only for the correlation slope of IPAQ 10-minute moderate-vigorous activity reliability.
Límites e incertidumbre
- 1With 89 participants, estimates of agreement are imprecise and subgroup comparisons by sex have little power.
- 2The accelerometer is itself an estimate, and its cut-off points define what counts as sedentary or moderate-vigorous.
- 3The abstract gives no correlation coefficients or confidence intervals, so the size of the disagreement is unclear.
- 4This reading is based on the abstract only.
Relevancia práctica
If you or a relative are asked to recall weekly sitting and exercise time, expect large errors. The authors concluded that the IPAQ is not suitable for assessing older adults' habitual physical behaviour. A worn sensor is likely to give a more reliable picture than memory.
Tus datos
For an older adult, sensor-based daily steps or active minutes from the same wrist or thigh device are a better basis for trends than estimating from memory. Compare weeks using the same device and wear pattern.
Cómo interpretar la evidencia
Agreement is specific to the device, firmware, reference, population and setting. Correlation is not agreement, and validating a metric is not proof of diagnostic or treatment benefit.
Resumen estructurado de los autores English
El resumen original en inglés se reproduce con atribución bajo la licencia indicada. Es una fuente, no una interpretación de MoveVitals. El análisis preparado figura arriba; verifica los resultados importantes en la fuente.
Background
The aim was to determine the reliability and validity of IPAQ measured sedentary behaviour (SB) and moderate-vigorous physical activity (MVPA) in older persons whilst examining any sex differences in reliability and validity results.
Method
89 participants (73.7 ± 6.3 years, 54% female) completed the IPAQ. Participants were fitted with a thigh mounted triaxial accelerometer (GeneActiv Original) for seven consecutive days and subsequently completed a second IPAQ.
Results
IPAQ showed weak reliability qualities for Total SB (h·week-1) and 10 minute MVPA (accumulated in bouts ≥ 10 continuous minutes, h·week-1). IPAQ had poor concurrent validity qualities for Total SB, 10 minute MVPA, but not Sporadic MVPA (accumulated in bouts < 10 continuous minutes, h·week-1). IPAQ only categorised participant physical behaviour classification correctly 2% of the time. Sex differences were only present for the correlation slope of IPAQ 10 minute MVPA reliability measures.
Conclusion
Our data suggests that the IPAQ is not suitable for assessing older adults habitual physical behaviour.
Fuentes y atribución
Reliability and validity of the international physical activity questionnaire compared to calibrated accelerometer cut-off points in the quantification of sedentary behaviour and physical activity in older adults.
Ryan DJ, Wullems JA, Stebbings GK, Morse CI, Stewart CE, Onambele-Pearson GL.
PloS one · 2018-04-19
DOI: 10.1371/journal.pone.0195712 ↗PubMed · 29672534 ↗Europe PMC · Licencia registrada: cc by ↗Abstract © the original authors, reproduced under the recorded open licence. Translations support reading; use the English record to check terminology and numerical results. Our methodological interpretation is separate from the authors’ conclusions.
Interpretación editorial de MoveVitals · contenido educativo · sin revisión clínica individual registrada
Fuentes verificadas 2026-11-01
Guías prácticas
Leer en contexto
Activity–stroke and heart attack curves differ by accelerometer processing method
Among 90,237 UK Biobank adults free of cardiovascular disease at baseline, followed until December 2022 for 1,298 strokes and 2,031 myocardial infarctions, the shape of the link between moderate-vigorous physical activity (MVPA) and each outcome depended on how the accelerometer data were processed. For stroke, hazard fell in a straight line only with the machine-learning metric; for myocardial infarction, two metrics gave a curved decline and activity counts a straight one. The abstract gives no hazard ratios, so it shows that methods disagree, not which one is right, and the findings are observational associations.
Preventive Medicine
Smartwatch data as forensic evidence: heart rate is best validated, the rest uneven
A systematic review and meta-analysis of studies on smartwatches from four major brands, framed around digital forensics, found that heart rate was both the most studied and the most accurate measure. Step count, distance, energy expenditure, activity classification and sleep were less consistently validated, and results varied by brand, protocol and reporting. The abstract gives no pooled numbers, and most studies were run in healthy people in laboratories, so it cannot say how a particular watch performs for a particular person in daily life.
Forensic Science International
Activity trackers: about 1,800 more steps a day, but small effects on other outcomes
An umbrella review of 39 systematic reviews and meta-analyses, covering 163,992 participants, found that activity trackers were associated with more physical activity (SMD 0.3–0.6), equating to about 1,800 extra steps and 40 minutes more walking per day, and with a bodyweight reduction of about 1 kg. Effects on blood pressure, cholesterol, glycosylated haemoglobin, quality of life and pain were typically small and often non-significant. The abstract does not say what else came with the trackers in these programs or how much the reviews overlap, so the gains cannot be credited to the device alone.
The Lancet Digital Health
Seven sleep trackers: good at spotting sleep, weak on wake and sleep stages
In a sleep laboratory, 34 healthy young adults wore a subset of seven consumer sleep trackers for three nights. Against polysomnography every device detected sleep very well (sensitivity 0.93 or higher) but caught wake poorly (specificity 0.18–0.54), and five of the seven matched or beat research actigraphy (specificity 0.39). Sleep-stage estimates were inconsistent, and the participants were healthy adults aged 18 to 35 in a fixed 8-hour bed window, with each device tested in only 11 to 20 of them, so the results say little about people with sleep problems.
Sleep

